Performance investigation on a 4-bed adsorption desalination cycle with internal heat recovery scheme

Thu Kyaw, Hideharu Yanagi, Bidyut Baran Saha, Kim Choon Ng

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Multi-bed adsorption cycle with the internal heat recovery between the condenser and the evaporator is investigated for desalination application. A numerical model is developed for a 4-bed adsorption cycle implemented with the master-and-slave configuration and the aforementioned internal heat recovery scheme. The present model captures the reversed adsorption/desorption phenomena frequently associated with the unmatched switching periods. Mesoporous silica gel and water vapor emanated from the evaporation of the seawater are employed as the adsorbent and adsorbate pair. The experimental data and investigation for such configurations are reported for the first time at heat source temperatures from 50 °C to 70 °C. The numerical model is validated rigorously and the parametric study is conducted for the performance of the cycle at assorted operation conditions such as hot and cooling water inlet temperatures and the cycle times. The specific daily water production (SDWP) of the present cycle is found to be about 10 m3/day per tonne of silica gel for the heat source temperature at 70 °C. Performance comparison is conducted for various types of adsorption desalination cycles. It is observed that the AD cycle with the current configuration provides superior performance whilst is operational at unprecedentedly low heat source temperature as low as 50 °C.

Original languageEnglish
Pages (from-to)88-96
Number of pages9
JournalDesalination
Volume402
DOIs
Publication statusPublished - Jan 16 2017

Fingerprint

Waste heat utilization
Desalination
desalination
heat source
adsorption
Adsorption
Silica Gel
Silica gel
Numerical models
gel
silica
temperature
Temperature
slave
cooling water
Steam
Cooling water
Evaporators
Adsorbates
Seawater

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)
  • Materials Science(all)
  • Water Science and Technology
  • Mechanical Engineering

Cite this

Performance investigation on a 4-bed adsorption desalination cycle with internal heat recovery scheme. / Kyaw, Thu; Yanagi, Hideharu; Saha, Bidyut Baran; Ng, Kim Choon.

In: Desalination, Vol. 402, 16.01.2017, p. 88-96.

Research output: Contribution to journalArticle

@article{f133788d795546959d8d8e5557ececab,
title = "Performance investigation on a 4-bed adsorption desalination cycle with internal heat recovery scheme",
abstract = "Multi-bed adsorption cycle with the internal heat recovery between the condenser and the evaporator is investigated for desalination application. A numerical model is developed for a 4-bed adsorption cycle implemented with the master-and-slave configuration and the aforementioned internal heat recovery scheme. The present model captures the reversed adsorption/desorption phenomena frequently associated with the unmatched switching periods. Mesoporous silica gel and water vapor emanated from the evaporation of the seawater are employed as the adsorbent and adsorbate pair. The experimental data and investigation for such configurations are reported for the first time at heat source temperatures from 50 °C to 70 °C. The numerical model is validated rigorously and the parametric study is conducted for the performance of the cycle at assorted operation conditions such as hot and cooling water inlet temperatures and the cycle times. The specific daily water production (SDWP) of the present cycle is found to be about 10 m3/day per tonne of silica gel for the heat source temperature at 70 °C. Performance comparison is conducted for various types of adsorption desalination cycles. It is observed that the AD cycle with the current configuration provides superior performance whilst is operational at unprecedentedly low heat source temperature as low as 50 °C.",
author = "Thu Kyaw and Hideharu Yanagi and Saha, {Bidyut Baran} and Ng, {Kim Choon}",
year = "2017",
month = "1",
day = "16",
doi = "10.1016/j.desal.2016.09.027",
language = "English",
volume = "402",
pages = "88--96",
journal = "Desalination",
issn = "0011-9164",
publisher = "Elsevier",

}

TY - JOUR

T1 - Performance investigation on a 4-bed adsorption desalination cycle with internal heat recovery scheme

AU - Kyaw, Thu

AU - Yanagi, Hideharu

AU - Saha, Bidyut Baran

AU - Ng, Kim Choon

PY - 2017/1/16

Y1 - 2017/1/16

N2 - Multi-bed adsorption cycle with the internal heat recovery between the condenser and the evaporator is investigated for desalination application. A numerical model is developed for a 4-bed adsorption cycle implemented with the master-and-slave configuration and the aforementioned internal heat recovery scheme. The present model captures the reversed adsorption/desorption phenomena frequently associated with the unmatched switching periods. Mesoporous silica gel and water vapor emanated from the evaporation of the seawater are employed as the adsorbent and adsorbate pair. The experimental data and investigation for such configurations are reported for the first time at heat source temperatures from 50 °C to 70 °C. The numerical model is validated rigorously and the parametric study is conducted for the performance of the cycle at assorted operation conditions such as hot and cooling water inlet temperatures and the cycle times. The specific daily water production (SDWP) of the present cycle is found to be about 10 m3/day per tonne of silica gel for the heat source temperature at 70 °C. Performance comparison is conducted for various types of adsorption desalination cycles. It is observed that the AD cycle with the current configuration provides superior performance whilst is operational at unprecedentedly low heat source temperature as low as 50 °C.

AB - Multi-bed adsorption cycle with the internal heat recovery between the condenser and the evaporator is investigated for desalination application. A numerical model is developed for a 4-bed adsorption cycle implemented with the master-and-slave configuration and the aforementioned internal heat recovery scheme. The present model captures the reversed adsorption/desorption phenomena frequently associated with the unmatched switching periods. Mesoporous silica gel and water vapor emanated from the evaporation of the seawater are employed as the adsorbent and adsorbate pair. The experimental data and investigation for such configurations are reported for the first time at heat source temperatures from 50 °C to 70 °C. The numerical model is validated rigorously and the parametric study is conducted for the performance of the cycle at assorted operation conditions such as hot and cooling water inlet temperatures and the cycle times. The specific daily water production (SDWP) of the present cycle is found to be about 10 m3/day per tonne of silica gel for the heat source temperature at 70 °C. Performance comparison is conducted for various types of adsorption desalination cycles. It is observed that the AD cycle with the current configuration provides superior performance whilst is operational at unprecedentedly low heat source temperature as low as 50 °C.

UR - http://www.scopus.com/inward/record.url?scp=84991387680&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991387680&partnerID=8YFLogxK

U2 - 10.1016/j.desal.2016.09.027

DO - 10.1016/j.desal.2016.09.027

M3 - Article

AN - SCOPUS:84991387680

VL - 402

SP - 88

EP - 96

JO - Desalination

JF - Desalination

SN - 0011-9164

ER -