Abstract

The objective is to develop a novel methodology to analyze cortisol levels in saliva as an index of neuroendocrine response. In order to realize a portable, rapid and hand held biosensor of cortisol, we proposed an immuno-chromatographic test-strip based biosensor consisting of a disposable test-strip and a monitor. A fabricated disposable type test-strip has a size of 5 × 1.5 × 50 mm3. In order to realize an immuno-chromatographic test-strip, a glucose oxidase (GOD) -cortisol conjugate was newly synthesized, because the speed and selectivity of immunological reactions is particularly attractive as a strategy for molecular recognition of cortisol. The synthesized molecule was identified as the GOD-cortisol conjugate by both its molecular weight and specific detection of cortisol. Three min after addition of GOD enzyme assay solution, a color change reaction at a test line was observed. The R2 value for the calibration curve of the cortisol test strip was 0.95, and the relationship between its reflectance, r, and the cortisol level was r = 0.629 (1-0.232e (-1.78 x cortisol)). The fabricated cortisol biosensor enabled us to analyze cortisol concentrations between 1 - 10 ng/ml within 25 min of dropping a cortisol solution on the test strip. Thus, it is suggested that the cortisol biosensor may possibly be used for point-of-use measurements in hospitals.

Original languageEnglish
Title of host publicationIEEE Sensors 2009 Conference - SENSORS 2009
Pages343-346
Number of pages4
DOIs
Publication statusPublished - Dec 1 2009
Externally publishedYes
EventIEEE Sensors 2009 Conference - SENSORS 2009 - Christchurch, New Zealand
Duration: Oct 25 2009Oct 28 2009

Publication series

NameProceedings of IEEE Sensors

Other

OtherIEEE Sensors 2009 Conference - SENSORS 2009
CountryNew Zealand
CityChristchurch
Period10/25/0910/28/09

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this

Yamaguchi, M., Yoshikawa, S., Tahara, Y., Niwa, D., Imai, Y., & Shetty, V. (2009). Point-of-use measurement of salivary cortisol levels. In IEEE Sensors 2009 Conference - SENSORS 2009 (pp. 343-346). [5398143] (Proceedings of IEEE Sensors). https://doi.org/10.1109/ICSENS.2009.5398143