Abstract
Using a single-wire gas counter filled with magic gas mixtures, position sensing was performed in the transition region from the proportional to the self-quenching streamer (SQS) mode. Used gas mixtures were Ar-iso -freon13Bl known as an original magic gas mixture, and Both mixtures contain several sorts of concentration of 0.15, 0.45, 0.90 and 1.1 percent.
Original language | English |
---|---|
Pages (from-to) | 218-222 |
Number of pages | 5 |
Journal | IEEE Transactions on Nuclear Science |
Volume | 36 |
Issue number | 1 |
DOIs | |
Publication status | Published - Feb 1989 |
All Science Journal Classification (ASJC) codes
- Nuclear and High Energy Physics
- Nuclear Energy and Engineering
- Electrical and Electronic Engineering