Potentiometric Determination of Bromate Using an Fe(III)-Fe(II) Potential Buffer by Circulatory Flow-Injection Analysis

Hiroki Ohura, Toshihiko Imato, Kiminori Kameda, Sumio Yamasaki

Research output: Contribution to journalArticlepeer-review

10 Citations (Scopus)

Abstract

A method for the potentiometric determination of bromate by circulatory flow injection analysis (CFIA) is described. The procedure involves the use of an Fe(III)-Fe(II) potential buffer solution, which is recycled via a reservoir. The analytical method is based on a linear relationship between the concentration of bromate and a very transient potential change in the electrode potential due to the generation of intermediate bromine during the reaction of bromate with the Fe(III)-Fe(II) potential buffer solution, which also contains NaBr, (NH 4 ) 6 Mo 7 O 24 and H 2 SO 4 . An aliquot (5 μl) of a bromate sample solution was injected into the stream of the potential buffer solution, 100 ml of which was circulated at a flow rate of 1 ml/min; the potential buffer solution stream was then returned to the reservoir after passing through a flow-through redox electrode detector. A potential change due to the reaction of the injected sample with the potential buffer in a reaction coil was measured with the detector in the form of a peak signal. The effects of the bromide, sulfuric acid and Fe(III)-Fe(II) concentrations in the potential buffer, and length of the reaction coil on the peak heights were examined in order to optimize the proposed CFIA method. The analytical sensitivities to bromate were 5.6 mV/μM for 1 × 10 -2 M and 30.9 mV/μM for 1 × 10 -3 M in the concentration of Fe(III)-Fe(II) in a potential buffer solution containing 0.35 M NaBr, 0.2% (NH 4 ) 6 Mo 7 O 24 and 1 M H 2 SO 4 . The detection limit of bromate obtained by a 1 × 10 -3 M Fe(III)-Fe(II) potential buffer solution was 0.02 μM (2.5 ppb). The numbers of repetitive determinations in which the relative sensitivities within 5% were regarded as being tolerated were ca. 4000 and 2000 for the use of only 100 ml of 1 × 10 -2 M and 1 × 10 -3 M Fe(III)-Fe(II) potential buffer solution, respectively.

Original languageEnglish
Pages (from-to)513-518
Number of pages6
Journalanalytical sciences
Volume20
Issue number3
DOIs
Publication statusPublished - Mar 2004

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Fingerprint Dive into the research topics of 'Potentiometric Determination of Bromate Using an Fe(III)-Fe(II) Potential Buffer by Circulatory Flow-Injection Analysis'. Together they form a unique fingerprint.

Cite this