Potentiometric flow-injection determination of boron by using a flow-through tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode

Toshihiko Imato, Takeshi Yoshizuka, Nobuhiko Ishibashi

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A highly sensitive tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode was constructed and applied to a detector in the flow-injection determination of boron. Boron at the 10 ng ml -1 level can be determined by converting it to tetrafluoroborate ion in a flow of hydrofluoric acid. A sampling rate of 30 h -1 was achieved with a relative standard deviation of less than 2%.

Original languageEnglish
Pages (from-to)139-141
Number of pages3
JournalAnalytica Chimica Acta
Volume233
Issue numberC
DOIs
Publication statusPublished - Jan 1 1990

Fingerprint

Vinyl Chloride
Boron
boron
Electrodes
electrode
chloride
Ions
Hydrofluoric Acid
membrane
Membranes
hydrofluoric acid
Injections
ion
Sampling
Detectors
sampling
rate
detector

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy

Cite this

Potentiometric flow-injection determination of boron by using a flow-through tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode. / Imato, Toshihiko; Yoshizuka, Takeshi; Ishibashi, Nobuhiko.

In: Analytica Chimica Acta, Vol. 233, No. C, 01.01.1990, p. 139-141.

Research output: Contribution to journalArticle

@article{621bd96d79c84bb396409948e8195891,
title = "Potentiometric flow-injection determination of boron by using a flow-through tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode",
abstract = "A highly sensitive tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode was constructed and applied to a detector in the flow-injection determination of boron. Boron at the 10 ng ml -1 level can be determined by converting it to tetrafluoroborate ion in a flow of hydrofluoric acid. A sampling rate of 30 h -1 was achieved with a relative standard deviation of less than 2{\%}.",
author = "Toshihiko Imato and Takeshi Yoshizuka and Nobuhiko Ishibashi",
year = "1990",
month = "1",
day = "1",
doi = "10.1016/S0003-2670(00)83470-4",
language = "English",
volume = "233",
pages = "139--141",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",
number = "C",

}

TY - JOUR

T1 - Potentiometric flow-injection determination of boron by using a flow-through tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode

AU - Imato, Toshihiko

AU - Yoshizuka, Takeshi

AU - Ishibashi, Nobuhiko

PY - 1990/1/1

Y1 - 1990/1/1

N2 - A highly sensitive tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode was constructed and applied to a detector in the flow-injection determination of boron. Boron at the 10 ng ml -1 level can be determined by converting it to tetrafluoroborate ion in a flow of hydrofluoric acid. A sampling rate of 30 h -1 was achieved with a relative standard deviation of less than 2%.

AB - A highly sensitive tetrafluoroborate ion-selective poly(vinyl chloride) membrane electrode was constructed and applied to a detector in the flow-injection determination of boron. Boron at the 10 ng ml -1 level can be determined by converting it to tetrafluoroborate ion in a flow of hydrofluoric acid. A sampling rate of 30 h -1 was achieved with a relative standard deviation of less than 2%.

UR - http://www.scopus.com/inward/record.url?scp=0025279162&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025279162&partnerID=8YFLogxK

U2 - 10.1016/S0003-2670(00)83470-4

DO - 10.1016/S0003-2670(00)83470-4

M3 - Article

AN - SCOPUS:0025279162

VL - 233

SP - 139

EP - 141

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

IS - C

ER -