Production of 95mTc for Compton camera imaging

Yuichi Hatsukawa, Kazuyuki Hashimoto, Kazuaki Tsukada, Tetsuya Sato, Masato Asai, Atsushi Toyoshima, Yasuki Nagai, Toru Tanimori, Shinya Sonoda, Shigeto Kabuki, Hideo Saji, Hiroyuki Kimura

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

With the development of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy gamma-rays are required. In this study, Technetium-95m which emits some gamma rays with higher than 200 keV was produced by the 95Mo(p,n)95mTc reaction. Image of gamma-rays from 95mTc was taken by a Compton gamma-ray camera.

Original languageEnglish
Pages (from-to)1283-1285
Number of pages3
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume303
Issue number2
DOIs
Publication statusPublished - Jan 1 2015

Fingerprint

Gamma Rays
Gamma rays
Cameras
Technetium
Imaging techniques
Gamma Cameras
Isotopes

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Nuclear Energy and Engineering
  • Radiology Nuclear Medicine and imaging
  • Pollution
  • Spectroscopy
  • Public Health, Environmental and Occupational Health
  • Health, Toxicology and Mutagenesis

Cite this

Hatsukawa, Y., Hashimoto, K., Tsukada, K., Sato, T., Asai, M., Toyoshima, A., ... Kimura, H. (2015). Production of 95mTc for Compton camera imaging. Journal of Radioanalytical and Nuclear Chemistry, 303(2), 1283-1285. https://doi.org/10.1007/s10967-014-3508-0

Production of 95mTc for Compton camera imaging. / Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Tsukada, Kazuaki; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Nagai, Yasuki; Tanimori, Toru; Sonoda, Shinya; Kabuki, Shigeto; Saji, Hideo; Kimura, Hiroyuki.

In: Journal of Radioanalytical and Nuclear Chemistry, Vol. 303, No. 2, 01.01.2015, p. 1283-1285.

Research output: Contribution to journalArticle

Hatsukawa, Y, Hashimoto, K, Tsukada, K, Sato, T, Asai, M, Toyoshima, A, Nagai, Y, Tanimori, T, Sonoda, S, Kabuki, S, Saji, H & Kimura, H 2015, 'Production of 95mTc for Compton camera imaging', Journal of Radioanalytical and Nuclear Chemistry, vol. 303, no. 2, pp. 1283-1285. https://doi.org/10.1007/s10967-014-3508-0
Hatsukawa Y, Hashimoto K, Tsukada K, Sato T, Asai M, Toyoshima A et al. Production of 95mTc for Compton camera imaging. Journal of Radioanalytical and Nuclear Chemistry. 2015 Jan 1;303(2):1283-1285. https://doi.org/10.1007/s10967-014-3508-0
Hatsukawa, Yuichi ; Hashimoto, Kazuyuki ; Tsukada, Kazuaki ; Sato, Tetsuya ; Asai, Masato ; Toyoshima, Atsushi ; Nagai, Yasuki ; Tanimori, Toru ; Sonoda, Shinya ; Kabuki, Shigeto ; Saji, Hideo ; Kimura, Hiroyuki. / Production of 95mTc for Compton camera imaging. In: Journal of Radioanalytical and Nuclear Chemistry. 2015 ; Vol. 303, No. 2. pp. 1283-1285.
@article{4c13b4a4e11f45319673e6e08bc74929,
title = "Production of 95mTc for Compton camera imaging",
abstract = "With the development of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy gamma-rays are required. In this study, Technetium-95m which emits some gamma rays with higher than 200 keV was produced by the 95Mo(p,n)95mTc reaction. Image of gamma-rays from 95mTc was taken by a Compton gamma-ray camera.",
author = "Yuichi Hatsukawa and Kazuyuki Hashimoto and Kazuaki Tsukada and Tetsuya Sato and Masato Asai and Atsushi Toyoshima and Yasuki Nagai and Toru Tanimori and Shinya Sonoda and Shigeto Kabuki and Hideo Saji and Hiroyuki Kimura",
year = "2015",
month = "1",
day = "1",
doi = "10.1007/s10967-014-3508-0",
language = "English",
volume = "303",
pages = "1283--1285",
journal = "Journal of Radioanalytical Chemistry",
issn = "0022-4081",
publisher = "Springer Netherlands",
number = "2",

}

TY - JOUR

T1 - Production of 95mTc for Compton camera imaging

AU - Hatsukawa, Yuichi

AU - Hashimoto, Kazuyuki

AU - Tsukada, Kazuaki

AU - Sato, Tetsuya

AU - Asai, Masato

AU - Toyoshima, Atsushi

AU - Nagai, Yasuki

AU - Tanimori, Toru

AU - Sonoda, Shinya

AU - Kabuki, Shigeto

AU - Saji, Hideo

AU - Kimura, Hiroyuki

PY - 2015/1/1

Y1 - 2015/1/1

N2 - With the development of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy gamma-rays are required. In this study, Technetium-95m which emits some gamma rays with higher than 200 keV was produced by the 95Mo(p,n)95mTc reaction. Image of gamma-rays from 95mTc was taken by a Compton gamma-ray camera.

AB - With the development of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy gamma-rays are required. In this study, Technetium-95m which emits some gamma rays with higher than 200 keV was produced by the 95Mo(p,n)95mTc reaction. Image of gamma-rays from 95mTc was taken by a Compton gamma-ray camera.

UR - http://www.scopus.com/inward/record.url?scp=84921326640&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84921326640&partnerID=8YFLogxK

U2 - 10.1007/s10967-014-3508-0

DO - 10.1007/s10967-014-3508-0

M3 - Article

AN - SCOPUS:84921326640

VL - 303

SP - 1283

EP - 1285

JO - Journal of Radioanalytical Chemistry

JF - Journal of Radioanalytical Chemistry

SN - 0022-4081

IS - 2

ER -