Abstract

A chemical heat pump with hydrolysis of acetal is a new heat-driven heat pump system for generation of cold thermal energy. Acetal hydrolysis consists of four elemental reactions. The most feasible rate-controlling step is in the hemiacetal production process. A reaction rate equation has been proposed from the above reaction mechanism. The generation rate of cold thermal energy evaluated from the reaction rate equation is high enough for the heat pump system. Improvement of the separation process is required for practical use of the heat pump system. The reaction system of acetal hydrolysis can be used for chemical heat transport.

Original languageEnglish
Pages (from-to)1421-1422
Number of pages2
Journalkagaku kogaku ronbunshu
Volume22
Issue number6
Publication statusPublished - Dec 1 1996

Fingerprint

Acetals
Heat pump systems
Thermal energy
Hydrolysis
Pumps
Reaction rates
Hot Temperature

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Proposal of a chemical heat pump with hydrolysis of acetal for cold thermal energy generation. / Watanabe, Takayuki; Akiyama, Naoya; Kanzawa, Atsushi.

In: kagaku kogaku ronbunshu, Vol. 22, No. 6, 01.12.1996, p. 1421-1422.

Research output: Contribution to journalArticle

@article{d7b83c9502934fac962fbe82b0b932cb,
title = "Proposal of a chemical heat pump with hydrolysis of acetal for cold thermal energy generation",
abstract = "A chemical heat pump with hydrolysis of acetal is a new heat-driven heat pump system for generation of cold thermal energy. Acetal hydrolysis consists of four elemental reactions. The most feasible rate-controlling step is in the hemiacetal production process. A reaction rate equation has been proposed from the above reaction mechanism. The generation rate of cold thermal energy evaluated from the reaction rate equation is high enough for the heat pump system. Improvement of the separation process is required for practical use of the heat pump system. The reaction system of acetal hydrolysis can be used for chemical heat transport.",
author = "Takayuki Watanabe and Naoya Akiyama and Atsushi Kanzawa",
year = "1996",
month = "12",
day = "1",
language = "English",
volume = "22",
pages = "1421--1422",
journal = "Kagaku Kogaku Ronbunshu",
issn = "0386-216X",
publisher = "The Society of Chemical Engineers, Japan",
number = "6",

}

TY - JOUR

T1 - Proposal of a chemical heat pump with hydrolysis of acetal for cold thermal energy generation

AU - Watanabe, Takayuki

AU - Akiyama, Naoya

AU - Kanzawa, Atsushi

PY - 1996/12/1

Y1 - 1996/12/1

N2 - A chemical heat pump with hydrolysis of acetal is a new heat-driven heat pump system for generation of cold thermal energy. Acetal hydrolysis consists of four elemental reactions. The most feasible rate-controlling step is in the hemiacetal production process. A reaction rate equation has been proposed from the above reaction mechanism. The generation rate of cold thermal energy evaluated from the reaction rate equation is high enough for the heat pump system. Improvement of the separation process is required for practical use of the heat pump system. The reaction system of acetal hydrolysis can be used for chemical heat transport.

AB - A chemical heat pump with hydrolysis of acetal is a new heat-driven heat pump system for generation of cold thermal energy. Acetal hydrolysis consists of four elemental reactions. The most feasible rate-controlling step is in the hemiacetal production process. A reaction rate equation has been proposed from the above reaction mechanism. The generation rate of cold thermal energy evaluated from the reaction rate equation is high enough for the heat pump system. Improvement of the separation process is required for practical use of the heat pump system. The reaction system of acetal hydrolysis can be used for chemical heat transport.

UR - http://www.scopus.com/inward/record.url?scp=21444456526&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=21444456526&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:21444456526

VL - 22

SP - 1421

EP - 1422

JO - Kagaku Kogaku Ronbunshu

JF - Kagaku Kogaku Ronbunshu

SN - 0386-216X

IS - 6

ER -