Proposal of calibration method for 3-D digestive endoscope using grid active stereo

Hirooki Aoki, Ryo Furukawa, Ishin Nishitani, Masahito Aoyama, Shinsaku Hiura, Yoko Kominami, Taiji Matsuo, Shigeto Yoshida, Shinji Tanaka, Ryusuke Sagawa, Hiroshi Kawasaki

Research output: Contribution to journalArticle

Abstract

Calibration for calculating the external parameter of camera-projector system is important, to make high-precision 3-D measurement by 3-D endoscope using the grid active stereo. In this paper, we propose a new calibration method with a sphere calibration object in a geometrically flexible camera-projector system, and we examine the validity of the proposed method. As the result of comparing using conventional calibration with a plane calibration object, it is clarified that the proposed method resolves the scaling imprecision, that is a problem of the conventional method. Thus, the proposed method has higher potential of measurement accuracy. In addition, it is the advantage of the proposed method that precision estimation of calibration parameters with a low number of input images is possible.

Original languageEnglish
Pages (from-to)97-107
Number of pages11
JournalTransactions of Japanese Society for Medical and Biological Engineering
Volume52
Issue number2
DOIs
Publication statusPublished - Jan 1 2014

Fingerprint

Endoscopy
Calibration
Cameras

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

Cite this

Proposal of calibration method for 3-D digestive endoscope using grid active stereo. / Aoki, Hirooki; Furukawa, Ryo; Nishitani, Ishin; Aoyama, Masahito; Hiura, Shinsaku; Kominami, Yoko; Matsuo, Taiji; Yoshida, Shigeto; Tanaka, Shinji; Sagawa, Ryusuke; Kawasaki, Hiroshi.

In: Transactions of Japanese Society for Medical and Biological Engineering, Vol. 52, No. 2, 01.01.2014, p. 97-107.

Research output: Contribution to journalArticle

Aoki, H, Furukawa, R, Nishitani, I, Aoyama, M, Hiura, S, Kominami, Y, Matsuo, T, Yoshida, S, Tanaka, S, Sagawa, R & Kawasaki, H 2014, 'Proposal of calibration method for 3-D digestive endoscope using grid active stereo', Transactions of Japanese Society for Medical and Biological Engineering, vol. 52, no. 2, pp. 97-107. https://doi.org/10.11239/jsmbe.52.97
Aoki, Hirooki ; Furukawa, Ryo ; Nishitani, Ishin ; Aoyama, Masahito ; Hiura, Shinsaku ; Kominami, Yoko ; Matsuo, Taiji ; Yoshida, Shigeto ; Tanaka, Shinji ; Sagawa, Ryusuke ; Kawasaki, Hiroshi. / Proposal of calibration method for 3-D digestive endoscope using grid active stereo. In: Transactions of Japanese Society for Medical and Biological Engineering. 2014 ; Vol. 52, No. 2. pp. 97-107.
@article{da104ab16a334743a1dbcf7963efb81a,
title = "Proposal of calibration method for 3-D digestive endoscope using grid active stereo",
abstract = "Calibration for calculating the external parameter of camera-projector system is important, to make high-precision 3-D measurement by 3-D endoscope using the grid active stereo. In this paper, we propose a new calibration method with a sphere calibration object in a geometrically flexible camera-projector system, and we examine the validity of the proposed method. As the result of comparing using conventional calibration with a plane calibration object, it is clarified that the proposed method resolves the scaling imprecision, that is a problem of the conventional method. Thus, the proposed method has higher potential of measurement accuracy. In addition, it is the advantage of the proposed method that precision estimation of calibration parameters with a low number of input images is possible.",
author = "Hirooki Aoki and Ryo Furukawa and Ishin Nishitani and Masahito Aoyama and Shinsaku Hiura and Yoko Kominami and Taiji Matsuo and Shigeto Yoshida and Shinji Tanaka and Ryusuke Sagawa and Hiroshi Kawasaki",
year = "2014",
month = "1",
day = "1",
doi = "10.11239/jsmbe.52.97",
language = "English",
volume = "52",
pages = "97--107",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Japanese Society for Medical and Biological Engineering",
number = "2",

}

TY - JOUR

T1 - Proposal of calibration method for 3-D digestive endoscope using grid active stereo

AU - Aoki, Hirooki

AU - Furukawa, Ryo

AU - Nishitani, Ishin

AU - Aoyama, Masahito

AU - Hiura, Shinsaku

AU - Kominami, Yoko

AU - Matsuo, Taiji

AU - Yoshida, Shigeto

AU - Tanaka, Shinji

AU - Sagawa, Ryusuke

AU - Kawasaki, Hiroshi

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Calibration for calculating the external parameter of camera-projector system is important, to make high-precision 3-D measurement by 3-D endoscope using the grid active stereo. In this paper, we propose a new calibration method with a sphere calibration object in a geometrically flexible camera-projector system, and we examine the validity of the proposed method. As the result of comparing using conventional calibration with a plane calibration object, it is clarified that the proposed method resolves the scaling imprecision, that is a problem of the conventional method. Thus, the proposed method has higher potential of measurement accuracy. In addition, it is the advantage of the proposed method that precision estimation of calibration parameters with a low number of input images is possible.

AB - Calibration for calculating the external parameter of camera-projector system is important, to make high-precision 3-D measurement by 3-D endoscope using the grid active stereo. In this paper, we propose a new calibration method with a sphere calibration object in a geometrically flexible camera-projector system, and we examine the validity of the proposed method. As the result of comparing using conventional calibration with a plane calibration object, it is clarified that the proposed method resolves the scaling imprecision, that is a problem of the conventional method. Thus, the proposed method has higher potential of measurement accuracy. In addition, it is the advantage of the proposed method that precision estimation of calibration parameters with a low number of input images is possible.

UR - http://www.scopus.com/inward/record.url?scp=84940302288&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940302288&partnerID=8YFLogxK

U2 - 10.11239/jsmbe.52.97

DO - 10.11239/jsmbe.52.97

M3 - Article

AN - SCOPUS:84940302288

VL - 52

SP - 97

EP - 107

JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai

JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai

SN - 1347-443X

IS - 2

ER -