Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment

Yuki Tsutsumi, Tetsuichi Kishishita, Yutaro Sato, Masayoshi Shoji, Manobu M. Tanaka, Tsutomu Mibe, Junji Tojo

Research output: Contribution to journalConference article

Abstract

We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8 ns with a sufficient dynamic range of 6 MIPs and pulse width of 45 ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.

Original languageEnglish
JournalProceedings of Science
Volume343
Publication statusPublished - Jan 1 2018
Event2018 Topical Workshop on Electronics for Particle Physics, TWEPP 2018 - Antwerp, Belgium
Duration: Sep 17 2018Sep 21 2018

Fingerprint

Nuclear instrumentation
Electric dipole moments
Silicon sensors
Positrons
Application specific integrated circuits
Charged particles
Magnetic moments
Detectors
Silicon
Experiments
Momentum
Physics
Data storage equipment

All Science Journal Classification (ASJC) codes

  • General

Cite this

Tsutsumi, Y., Kishishita, T., Sato, Y., Shoji, M., Tanaka, M. M., Mibe, T., & Tojo, J. (2018). Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment. Proceedings of Science, 343.

Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment. / Tsutsumi, Yuki; Kishishita, Tetsuichi; Sato, Yutaro; Shoji, Masayoshi; Tanaka, Manobu M.; Mibe, Tsutomu; Tojo, Junji.

In: Proceedings of Science, Vol. 343, 01.01.2018.

Research output: Contribution to journalConference article

Tsutsumi, Y, Kishishita, T, Sato, Y, Shoji, M, Tanaka, MM, Mibe, T & Tojo, J 2018, 'Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment', Proceedings of Science, vol. 343.
Tsutsumi Y, Kishishita T, Sato Y, Shoji M, Tanaka MM, Mibe T et al. Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment. Proceedings of Science. 2018 Jan 1;343.
Tsutsumi, Yuki ; Kishishita, Tetsuichi ; Sato, Yutaro ; Shoji, Masayoshi ; Tanaka, Manobu M. ; Mibe, Tsutomu ; Tojo, Junji. / Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment. In: Proceedings of Science. 2018 ; Vol. 343.
@article{728dc12237fb42cbadd820b7c19de3ee,
title = "Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment",
abstract = "We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8 ns with a sufficient dynamic range of 6 MIPs and pulse width of 45 ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.",
author = "Yuki Tsutsumi and Tetsuichi Kishishita and Yutaro Sato and Masayoshi Shoji and Tanaka, {Manobu M.} and Tsutomu Mibe and Junji Tojo",
year = "2018",
month = "1",
day = "1",
language = "English",
volume = "343",
journal = "Proceedings of Science",
issn = "1824-8039",
publisher = "Sissa Medialab Srl",

}

TY - JOUR

T1 - Prototype front-end ASIC for silicon-strip detectors of J-PARC muon g-2/EDM experiment

AU - Tsutsumi, Yuki

AU - Kishishita, Tetsuichi

AU - Sato, Yutaro

AU - Shoji, Masayoshi

AU - Tanaka, Manobu M.

AU - Mibe, Tsutomu

AU - Tojo, Junji

PY - 2018/1/1

Y1 - 2018/1/1

N2 - We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8 ns with a sufficient dynamic range of 6 MIPs and pulse width of 45 ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.

AB - We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8 ns with a sufficient dynamic range of 6 MIPs and pulse width of 45 ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.

UR - http://www.scopus.com/inward/record.url?scp=85072852447&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85072852447&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:85072852447

VL - 343

JO - Proceedings of Science

JF - Proceedings of Science

SN - 1824-8039

ER -