Purge and trap sampling coupled to curie point thermal desorption for the detection of parts per trillion 2,4,6-trichloroanisole in water

Roman Selyanchyn, Serhiy Korposh, Toshiro Matsui, Hidetaka Matsui, Seung Woo Lee

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

GC-MS analysis based on purge and trap sampling followed by Curie point thermal desorption was examined for the quantitative determination of 2,4,6-trichloroanisole in aqueous solutions. The method developed showed linearity in single ion monitoring mode over a TCA concentration range of 0.12-120 ng L -1 (parts-per-trillion).

Original languageEnglish
Pages (from-to)317-321
Number of pages5
JournalChromatographia
Volume71
Issue number3-4
DOIs
Publication statusPublished - Feb 1 2010

Fingerprint

Thermal desorption
Hot Temperature
Ions
Sampling
Water
Monitoring
2,4,6-trichloroanisole

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Biochemistry
  • Clinical Biochemistry
  • Organic Chemistry

Cite this

Purge and trap sampling coupled to curie point thermal desorption for the detection of parts per trillion 2,4,6-trichloroanisole in water. / Selyanchyn, Roman; Korposh, Serhiy; Matsui, Toshiro; Matsui, Hidetaka; Lee, Seung Woo.

In: Chromatographia, Vol. 71, No. 3-4, 01.02.2010, p. 317-321.

Research output: Contribution to journalArticle

@article{a60d254caff149f9911b955b741e3eca,
title = "Purge and trap sampling coupled to curie point thermal desorption for the detection of parts per trillion 2,4,6-trichloroanisole in water",
abstract = "GC-MS analysis based on purge and trap sampling followed by Curie point thermal desorption was examined for the quantitative determination of 2,4,6-trichloroanisole in aqueous solutions. The method developed showed linearity in single ion monitoring mode over a TCA concentration range of 0.12-120 ng L -1 (parts-per-trillion).",
author = "Roman Selyanchyn and Serhiy Korposh and Toshiro Matsui and Hidetaka Matsui and Lee, {Seung Woo}",
year = "2010",
month = "2",
day = "1",
doi = "10.1365/s10337-009-1428-x",
language = "English",
volume = "71",
pages = "317--321",
journal = "Chromatographia",
issn = "0009-5893",
publisher = "Springer Vieweg",
number = "3-4",

}

TY - JOUR

T1 - Purge and trap sampling coupled to curie point thermal desorption for the detection of parts per trillion 2,4,6-trichloroanisole in water

AU - Selyanchyn, Roman

AU - Korposh, Serhiy

AU - Matsui, Toshiro

AU - Matsui, Hidetaka

AU - Lee, Seung Woo

PY - 2010/2/1

Y1 - 2010/2/1

N2 - GC-MS analysis based on purge and trap sampling followed by Curie point thermal desorption was examined for the quantitative determination of 2,4,6-trichloroanisole in aqueous solutions. The method developed showed linearity in single ion monitoring mode over a TCA concentration range of 0.12-120 ng L -1 (parts-per-trillion).

AB - GC-MS analysis based on purge and trap sampling followed by Curie point thermal desorption was examined for the quantitative determination of 2,4,6-trichloroanisole in aqueous solutions. The method developed showed linearity in single ion monitoring mode over a TCA concentration range of 0.12-120 ng L -1 (parts-per-trillion).

UR - http://www.scopus.com/inward/record.url?scp=77949263586&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77949263586&partnerID=8YFLogxK

U2 - 10.1365/s10337-009-1428-x

DO - 10.1365/s10337-009-1428-x

M3 - Article

AN - SCOPUS:77949263586

VL - 71

SP - 317

EP - 321

JO - Chromatographia

JF - Chromatographia

SN - 0009-5893

IS - 3-4

ER -