Abstract
We report here kinetic analyses of DNA ligation by using a DNA-immobilized quartz-crystal microbalance (QCM), which enables in situ real-time monitoring of both the binding of ligase and ligation reaction on DNA strands, as mass changes.
Original language | English |
---|---|
Pages (from-to) | 147-148 |
Number of pages | 2 |
Journal | Nucleic acids symposium series |
Issue number | 42 |
DOIs | |
Publication status | Published - 1999 |
Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Medicine(all)