Abstract
Ultrafine magnetite particles were applied to enzyme-linked immunosorbent assay (ELISA). For the assay of mouse IgG, anti-mouse IgG antibody or protein A was immobilized on the magnetite particles. The assay strategy was based on the sandwich method. Using anti-mouse IgG-magnetite and the spectrofluorometry, the mouse IgG standard curve was linear when the IgG concentration was between 5 μg/l-5 mg/l. Using these functional magnetite particles, we could shorten the assay time to one thirty-fifth that of the conventional method.
Original language | English |
---|---|
Pages (from-to) | 166-168 |
Number of pages | 3 |
Journal | Journal of Fermentation and Bioengineering |
Volume | 73 |
Issue number | 2 |
DOIs | |
Publication status | Published - 1992 |
Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Biotechnology
- Applied Microbiology and Biotechnology