Riming electrification in Hokuriku winter clouds and comparison with laboratory observations

Tsutomu Takahashi, Soichiro Sugimoto, Tetsuya Kawano, Kenji Suzuki

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Riming electrification is the main charge separation mechanism of thunderstorms, occurring mainly during graupel particle-ice crystal collisions. Laboratory experiments have found that charge separation polarity and magnitude depend critically on cloud water content and temperature. Several groups have mapped this dependence, but there are substantial differences between their results. These conflicting laboratory-derived riming electrification topographies can be tested by comparing them to field observations. Here, direct and simultaneous sonde-based measurement of both precipitation particle type and charge (videosonde) and cloud water content [hydrometeor videosonde (HYVIS)] in lightning-active Hokuriku winter clouds at Kashiwazaki, Niigata Prefecture, Japan, are reported. With decreasing height, summed graupel charge transitioned from negative to positive at a mean temperature of ≥11°C, and the mean peak cloud water content in the positive graupel domain was 0.4 g m-3. Thus, in cloud regions of relatively high temperature (≥-11°C) and low cloud water content (CWC; ≤0.4 g m-3), graupel particles were mainly positively charged. This result can be compared with those of laboratory riming experiments; for example, in this temperature/cloud water content domain, graupel electrification has been reported to be positive by Takahashi, largely negative in early reports using the Manchester cloud chamber, positive in later reports using the Cordoba and Manchester modified cloud chambers, and partially positive in a more recent report using the Cordoba cloud chamber.

Original languageEnglish
Pages (from-to)431-447
Number of pages17
JournalJournal of the Atmospheric Sciences
Volume74
Issue number2
DOIs
Publication statusPublished - Jan 1 2017

Fingerprint

electrification
cloud water
water content
winter
ice crystal
thunderstorm
lightning
water temperature
collision
temperature
comparison
laboratory
topography
particle

All Science Journal Classification (ASJC) codes

  • Atmospheric Science

Cite this

Riming electrification in Hokuriku winter clouds and comparison with laboratory observations. / Takahashi, Tsutomu; Sugimoto, Soichiro; Kawano, Tetsuya; Suzuki, Kenji.

In: Journal of the Atmospheric Sciences, Vol. 74, No. 2, 01.01.2017, p. 431-447.

Research output: Contribution to journalArticle

Takahashi, Tsutomu ; Sugimoto, Soichiro ; Kawano, Tetsuya ; Suzuki, Kenji. / Riming electrification in Hokuriku winter clouds and comparison with laboratory observations. In: Journal of the Atmospheric Sciences. 2017 ; Vol. 74, No. 2. pp. 431-447.
@article{e6a58b23c4bb4cdca1f464d451040069,
title = "Riming electrification in Hokuriku winter clouds and comparison with laboratory observations",
abstract = "Riming electrification is the main charge separation mechanism of thunderstorms, occurring mainly during graupel particle-ice crystal collisions. Laboratory experiments have found that charge separation polarity and magnitude depend critically on cloud water content and temperature. Several groups have mapped this dependence, but there are substantial differences between their results. These conflicting laboratory-derived riming electrification topographies can be tested by comparing them to field observations. Here, direct and simultaneous sonde-based measurement of both precipitation particle type and charge (videosonde) and cloud water content [hydrometeor videosonde (HYVIS)] in lightning-active Hokuriku winter clouds at Kashiwazaki, Niigata Prefecture, Japan, are reported. With decreasing height, summed graupel charge transitioned from negative to positive at a mean temperature of ≥11°C, and the mean peak cloud water content in the positive graupel domain was 0.4 g m-3. Thus, in cloud regions of relatively high temperature (≥-11°C) and low cloud water content (CWC; ≤0.4 g m-3), graupel particles were mainly positively charged. This result can be compared with those of laboratory riming experiments; for example, in this temperature/cloud water content domain, graupel electrification has been reported to be positive by Takahashi, largely negative in early reports using the Manchester cloud chamber, positive in later reports using the Cordoba and Manchester modified cloud chambers, and partially positive in a more recent report using the Cordoba cloud chamber.",
author = "Tsutomu Takahashi and Soichiro Sugimoto and Tetsuya Kawano and Kenji Suzuki",
year = "2017",
month = "1",
day = "1",
doi = "10.1175/JAS-D-16-0154.1",
language = "English",
volume = "74",
pages = "431--447",
journal = "Journals of the Atmospheric Sciences",
issn = "0022-4928",
publisher = "American Meteorological Society",
number = "2",

}

TY - JOUR

T1 - Riming electrification in Hokuriku winter clouds and comparison with laboratory observations

AU - Takahashi, Tsutomu

AU - Sugimoto, Soichiro

AU - Kawano, Tetsuya

AU - Suzuki, Kenji

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Riming electrification is the main charge separation mechanism of thunderstorms, occurring mainly during graupel particle-ice crystal collisions. Laboratory experiments have found that charge separation polarity and magnitude depend critically on cloud water content and temperature. Several groups have mapped this dependence, but there are substantial differences between their results. These conflicting laboratory-derived riming electrification topographies can be tested by comparing them to field observations. Here, direct and simultaneous sonde-based measurement of both precipitation particle type and charge (videosonde) and cloud water content [hydrometeor videosonde (HYVIS)] in lightning-active Hokuriku winter clouds at Kashiwazaki, Niigata Prefecture, Japan, are reported. With decreasing height, summed graupel charge transitioned from negative to positive at a mean temperature of ≥11°C, and the mean peak cloud water content in the positive graupel domain was 0.4 g m-3. Thus, in cloud regions of relatively high temperature (≥-11°C) and low cloud water content (CWC; ≤0.4 g m-3), graupel particles were mainly positively charged. This result can be compared with those of laboratory riming experiments; for example, in this temperature/cloud water content domain, graupel electrification has been reported to be positive by Takahashi, largely negative in early reports using the Manchester cloud chamber, positive in later reports using the Cordoba and Manchester modified cloud chambers, and partially positive in a more recent report using the Cordoba cloud chamber.

AB - Riming electrification is the main charge separation mechanism of thunderstorms, occurring mainly during graupel particle-ice crystal collisions. Laboratory experiments have found that charge separation polarity and magnitude depend critically on cloud water content and temperature. Several groups have mapped this dependence, but there are substantial differences between their results. These conflicting laboratory-derived riming electrification topographies can be tested by comparing them to field observations. Here, direct and simultaneous sonde-based measurement of both precipitation particle type and charge (videosonde) and cloud water content [hydrometeor videosonde (HYVIS)] in lightning-active Hokuriku winter clouds at Kashiwazaki, Niigata Prefecture, Japan, are reported. With decreasing height, summed graupel charge transitioned from negative to positive at a mean temperature of ≥11°C, and the mean peak cloud water content in the positive graupel domain was 0.4 g m-3. Thus, in cloud regions of relatively high temperature (≥-11°C) and low cloud water content (CWC; ≤0.4 g m-3), graupel particles were mainly positively charged. This result can be compared with those of laboratory riming experiments; for example, in this temperature/cloud water content domain, graupel electrification has been reported to be positive by Takahashi, largely negative in early reports using the Manchester cloud chamber, positive in later reports using the Cordoba and Manchester modified cloud chambers, and partially positive in a more recent report using the Cordoba cloud chamber.

UR - http://www.scopus.com/inward/record.url?scp=85011661219&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85011661219&partnerID=8YFLogxK

U2 - 10.1175/JAS-D-16-0154.1

DO - 10.1175/JAS-D-16-0154.1

M3 - Article

VL - 74

SP - 431

EP - 447

JO - Journals of the Atmospheric Sciences

JF - Journals of the Atmospheric Sciences

SN - 0022-4928

IS - 2

ER -