Robotic surgery setup simulation with the integration of inverse-kinematics computation and medical imaging

Mitsuhiro Hayashibe, Naoki Suzuki, Makoto Hashizume, Kozo Konishi, Asaki Hattori

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

At present, there are representative robot operation systems such as da Vinci and ZEUS which have realized minimally invasive surgery by the use of dexterous manipulators. In the operating room, medical staff must prepare and set up an environment in which the robot has optimal freedom of motion and its functions can be fully demonstrated for every case. The range of motion in which the robot can reach and be maneuvered is restricted by the fixed point of the trocar site. We have developed a preoperative planning system with the function of volume rendering of medical images and automatic positioning by applying an inverse-kinematics computation of surgical robot. The motion of a surgical robot can be simulated in advance with the intuitive interface and kinematics computation program running in the background of the system. If robotic surgery planning with volume rendering of DICOM images is possible, the discussion of a surgical plan can be directly made just after the diagnosis considering the patient-specific structure. This kind of setup platform would be essential for the future introduction of surgical robotics into an operating room.

Original languageEnglish
Pages (from-to)63-72
Number of pages10
JournalComputer Methods and Programs in Biomedicine
Volume83
Issue number1
DOIs
Publication statusPublished - Jul 1 2006

Fingerprint

Inverse kinematics
Medical imaging
Robotics
Diagnostic Imaging
Operating Rooms
Biomechanical Phenomena
Operating rooms
Volume rendering
Robots
Minimally Invasive Surgical Procedures
Medical Staff
Articular Range of Motion
Surgical Instruments
Digital Imaging and Communications in Medicine (DICOM)
Planning
Surgery
Manipulators
Kinematics
Robotic surgery

All Science Journal Classification (ASJC) codes

  • Software
  • Computer Science Applications
  • Health Informatics

Cite this

Robotic surgery setup simulation with the integration of inverse-kinematics computation and medical imaging. / Hayashibe, Mitsuhiro; Suzuki, Naoki; Hashizume, Makoto; Konishi, Kozo; Hattori, Asaki.

In: Computer Methods and Programs in Biomedicine, Vol. 83, No. 1, 01.07.2006, p. 63-72.

Research output: Contribution to journalArticle

Hayashibe, Mitsuhiro ; Suzuki, Naoki ; Hashizume, Makoto ; Konishi, Kozo ; Hattori, Asaki. / Robotic surgery setup simulation with the integration of inverse-kinematics computation and medical imaging. In: Computer Methods and Programs in Biomedicine. 2006 ; Vol. 83, No. 1. pp. 63-72.
@article{3246530d03c24477aa79c526004e146c,
title = "Robotic surgery setup simulation with the integration of inverse-kinematics computation and medical imaging",
abstract = "At present, there are representative robot operation systems such as da Vinci and ZEUS which have realized minimally invasive surgery by the use of dexterous manipulators. In the operating room, medical staff must prepare and set up an environment in which the robot has optimal freedom of motion and its functions can be fully demonstrated for every case. The range of motion in which the robot can reach and be maneuvered is restricted by the fixed point of the trocar site. We have developed a preoperative planning system with the function of volume rendering of medical images and automatic positioning by applying an inverse-kinematics computation of surgical robot. The motion of a surgical robot can be simulated in advance with the intuitive interface and kinematics computation program running in the background of the system. If robotic surgery planning with volume rendering of DICOM images is possible, the discussion of a surgical plan can be directly made just after the diagnosis considering the patient-specific structure. This kind of setup platform would be essential for the future introduction of surgical robotics into an operating room.",
author = "Mitsuhiro Hayashibe and Naoki Suzuki and Makoto Hashizume and Kozo Konishi and Asaki Hattori",
year = "2006",
month = "7",
day = "1",
doi = "10.1016/j.cmpb.2006.04.010",
language = "English",
volume = "83",
pages = "63--72",
journal = "Computer Methods and Programs in Biomedicine",
issn = "0169-2607",
publisher = "Elsevier Ireland Ltd",
number = "1",

}

TY - JOUR

T1 - Robotic surgery setup simulation with the integration of inverse-kinematics computation and medical imaging

AU - Hayashibe, Mitsuhiro

AU - Suzuki, Naoki

AU - Hashizume, Makoto

AU - Konishi, Kozo

AU - Hattori, Asaki

PY - 2006/7/1

Y1 - 2006/7/1

N2 - At present, there are representative robot operation systems such as da Vinci and ZEUS which have realized minimally invasive surgery by the use of dexterous manipulators. In the operating room, medical staff must prepare and set up an environment in which the robot has optimal freedom of motion and its functions can be fully demonstrated for every case. The range of motion in which the robot can reach and be maneuvered is restricted by the fixed point of the trocar site. We have developed a preoperative planning system with the function of volume rendering of medical images and automatic positioning by applying an inverse-kinematics computation of surgical robot. The motion of a surgical robot can be simulated in advance with the intuitive interface and kinematics computation program running in the background of the system. If robotic surgery planning with volume rendering of DICOM images is possible, the discussion of a surgical plan can be directly made just after the diagnosis considering the patient-specific structure. This kind of setup platform would be essential for the future introduction of surgical robotics into an operating room.

AB - At present, there are representative robot operation systems such as da Vinci and ZEUS which have realized minimally invasive surgery by the use of dexterous manipulators. In the operating room, medical staff must prepare and set up an environment in which the robot has optimal freedom of motion and its functions can be fully demonstrated for every case. The range of motion in which the robot can reach and be maneuvered is restricted by the fixed point of the trocar site. We have developed a preoperative planning system with the function of volume rendering of medical images and automatic positioning by applying an inverse-kinematics computation of surgical robot. The motion of a surgical robot can be simulated in advance with the intuitive interface and kinematics computation program running in the background of the system. If robotic surgery planning with volume rendering of DICOM images is possible, the discussion of a surgical plan can be directly made just after the diagnosis considering the patient-specific structure. This kind of setup platform would be essential for the future introduction of surgical robotics into an operating room.

UR - http://www.scopus.com/inward/record.url?scp=33745726010&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745726010&partnerID=8YFLogxK

U2 - 10.1016/j.cmpb.2006.04.010

DO - 10.1016/j.cmpb.2006.04.010

M3 - Article

C2 - 16828195

AN - SCOPUS:33745726010

VL - 83

SP - 63

EP - 72

JO - Computer Methods and Programs in Biomedicine

JF - Computer Methods and Programs in Biomedicine

SN - 0169-2607

IS - 1

ER -