Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns

F. Javanmardi, T. Sakae, Akihiro Nohtomi, Yusuke Uozumi, M. Matoba

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The most unfavorable phenomenon in 2D position sensing is the readout dependence of the two independent dimensions (X, Y). The patterned cathodes, such as the wedge-and-strip, Backgammon, Chevron and Triple Charge Division patterns, are very sensitive to the source displacement perpendicular to their position sensitive directions (X). This sensitivity results in severe dependance for the horizontal readout to the vertical readout. The predicted deviation due to vertical displacements of a given source, which is experimentally confirmed shows that the deviation varies with the source displacement along the X axes. This deviation has a maximum value (about 10% of the full length) at the center of the pattern. Since the deviation varies along the X direction, finding a transfer function for correcting the readout is impossible. Using the patterned cathodes in multi wire proportional counters are possible if the wire spacing is a multiple of the pattern width. Also, these cathodes can be used for two dimensional position sensing, without any limitation, if the readout position in the other dimension is done using drift times of the primary electrons. Using this combination, a high resolution (.25 mm) safe 2D ray trace type patterned telescope was manufactured for particle detection with low threshold energy.

Original languageEnglish
Title of host publicationIEEE Nuclear Science Symposium & Medical Imaging Conference
EditorsO. Nalcioglu
PublisherIEEE
Pages574-578
Number of pages5
Volume1
Publication statusPublished - 1997
Externally publishedYes
EventProceedings of the 1997 IEEE Nuclear Science Symposium - Albuquerque, NM, USA
Duration: Nov 9 1997Nov 15 1997

Other

OtherProceedings of the 1997 IEEE Nuclear Science Symposium
CityAlbuquerque, NM, USA
Period11/9/9711/15/97

Fingerprint

Hazards
Cathodes
Wire
Proportional counters
Telescopes
Transfer functions
Electrons

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Javanmardi, F., Sakae, T., Nohtomi, A., Uozumi, Y., & Matoba, M. (1997). Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns. In O. Nalcioglu (Ed.), IEEE Nuclear Science Symposium & Medical Imaging Conference (Vol. 1, pp. 574-578). IEEE.

Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns. / Javanmardi, F.; Sakae, T.; Nohtomi, Akihiro; Uozumi, Yusuke; Matoba, M.

IEEE Nuclear Science Symposium & Medical Imaging Conference. ed. / O. Nalcioglu. Vol. 1 IEEE, 1997. p. 574-578.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Javanmardi, F, Sakae, T, Nohtomi, A, Uozumi, Y & Matoba, M 1997, Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns. in O Nalcioglu (ed.), IEEE Nuclear Science Symposium & Medical Imaging Conference. vol. 1, IEEE, pp. 574-578, Proceedings of the 1997 IEEE Nuclear Science Symposium, Albuquerque, NM, USA, 11/9/97.
Javanmardi F, Sakae T, Nohtomi A, Uozumi Y, Matoba M. Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns. In Nalcioglu O, editor, IEEE Nuclear Science Symposium & Medical Imaging Conference. Vol. 1. IEEE. 1997. p. 574-578
Javanmardi, F. ; Sakae, T. ; Nohtomi, Akihiro ; Uozumi, Yusuke ; Matoba, M. / Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns. IEEE Nuclear Science Symposium & Medical Imaging Conference. editor / O. Nalcioglu. Vol. 1 IEEE, 1997. pp. 574-578
@inproceedings{aad7919789c542719ee12dbf27d65d92,
title = "Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns",
abstract = "The most unfavorable phenomenon in 2D position sensing is the readout dependence of the two independent dimensions (X, Y). The patterned cathodes, such as the wedge-and-strip, Backgammon, Chevron and Triple Charge Division patterns, are very sensitive to the source displacement perpendicular to their position sensitive directions (X). This sensitivity results in severe dependance for the horizontal readout to the vertical readout. The predicted deviation due to vertical displacements of a given source, which is experimentally confirmed shows that the deviation varies with the source displacement along the X axes. This deviation has a maximum value (about 10{\%} of the full length) at the center of the pattern. Since the deviation varies along the X direction, finding a transfer function for correcting the readout is impossible. Using the patterned cathodes in multi wire proportional counters are possible if the wire spacing is a multiple of the pattern width. Also, these cathodes can be used for two dimensional position sensing, without any limitation, if the readout position in the other dimension is done using drift times of the primary electrons. Using this combination, a high resolution (.25 mm) safe 2D ray trace type patterned telescope was manufactured for particle detection with low threshold energy.",
author = "F. Javanmardi and T. Sakae and Akihiro Nohtomi and Yusuke Uozumi and M. Matoba",
year = "1997",
language = "English",
volume = "1",
pages = "574--578",
editor = "O. Nalcioglu",
booktitle = "IEEE Nuclear Science Symposium & Medical Imaging Conference",
publisher = "IEEE",

}

TY - GEN

T1 - Severe hazards in two dimensional position sensing using wedge & strip and Backgammon based patterns

AU - Javanmardi, F.

AU - Sakae, T.

AU - Nohtomi, Akihiro

AU - Uozumi, Yusuke

AU - Matoba, M.

PY - 1997

Y1 - 1997

N2 - The most unfavorable phenomenon in 2D position sensing is the readout dependence of the two independent dimensions (X, Y). The patterned cathodes, such as the wedge-and-strip, Backgammon, Chevron and Triple Charge Division patterns, are very sensitive to the source displacement perpendicular to their position sensitive directions (X). This sensitivity results in severe dependance for the horizontal readout to the vertical readout. The predicted deviation due to vertical displacements of a given source, which is experimentally confirmed shows that the deviation varies with the source displacement along the X axes. This deviation has a maximum value (about 10% of the full length) at the center of the pattern. Since the deviation varies along the X direction, finding a transfer function for correcting the readout is impossible. Using the patterned cathodes in multi wire proportional counters are possible if the wire spacing is a multiple of the pattern width. Also, these cathodes can be used for two dimensional position sensing, without any limitation, if the readout position in the other dimension is done using drift times of the primary electrons. Using this combination, a high resolution (.25 mm) safe 2D ray trace type patterned telescope was manufactured for particle detection with low threshold energy.

AB - The most unfavorable phenomenon in 2D position sensing is the readout dependence of the two independent dimensions (X, Y). The patterned cathodes, such as the wedge-and-strip, Backgammon, Chevron and Triple Charge Division patterns, are very sensitive to the source displacement perpendicular to their position sensitive directions (X). This sensitivity results in severe dependance for the horizontal readout to the vertical readout. The predicted deviation due to vertical displacements of a given source, which is experimentally confirmed shows that the deviation varies with the source displacement along the X axes. This deviation has a maximum value (about 10% of the full length) at the center of the pattern. Since the deviation varies along the X direction, finding a transfer function for correcting the readout is impossible. Using the patterned cathodes in multi wire proportional counters are possible if the wire spacing is a multiple of the pattern width. Also, these cathodes can be used for two dimensional position sensing, without any limitation, if the readout position in the other dimension is done using drift times of the primary electrons. Using this combination, a high resolution (.25 mm) safe 2D ray trace type patterned telescope was manufactured for particle detection with low threshold energy.

UR - http://www.scopus.com/inward/record.url?scp=0031385611&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031385611&partnerID=8YFLogxK

M3 - Conference contribution

VL - 1

SP - 574

EP - 578

BT - IEEE Nuclear Science Symposium & Medical Imaging Conference

A2 - Nalcioglu, O.

PB - IEEE

ER -