Shrinkage forces due to polymerization of light-cured dental composite resin in cavities

Kazuo Arakawa

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

A new method has been developed for determining shrinkage forces due to polymerization of light-cured dental composite resin in artificial cylindrical cavities. The cavities were fabricated in stainless steel plates, and shrinkage forces were measured using a load cell inserted from the rear of the plate in place of the floor of the cavity. The cavities were 3 mm in diameter, and depths varied from 0.5 to 3.5 mm to study the effect of light intensity. Cavities were filled with a composite resin after being prepared with a bonding agent and were then irradiated for 20 s with a light-curing unit at a power of 300 mW/cm2. To study the effects of boundaries, two conditions were employed: a free surface condition without any restriction on the top surface of the cavity, and a constrained surface condition in which the top surface of the resin was bonded to a 1 mm thick transparent polymethyl methacrylate (PMMA) plate. The shrinkage forces were measured as functions of time and the cavity depth, and the following results were obtained. For both conditions, the force increased with time, mostly during the irradiation stage (20 s), and then increased slightly after the irradiation. The force measured at 300 s increased gradually with the cavity depth and exhibited a maximum value before decreasing gradually. The cavities with constrained surfaces yielded much greater shrinkage forces for any given cavity depth than those with free surface conditions.

Original languageEnglish
Pages (from-to)1052-1056
Number of pages5
JournalPolymer Testing
Volume29
Issue number8
DOIs
Publication statusPublished - Dec 1 2010

Fingerprint

Dental composites
Resins
Polymerization
Irradiation
Composite Resins
Stainless Steel
Polymethyl Methacrylate
Polymethyl methacrylates
Curing
Composite Dental Resin
Stainless steel
Composite materials

All Science Journal Classification (ASJC) codes

  • Organic Chemistry
  • Polymers and Plastics

Cite this

Shrinkage forces due to polymerization of light-cured dental composite resin in cavities. / Arakawa, Kazuo.

In: Polymer Testing, Vol. 29, No. 8, 01.12.2010, p. 1052-1056.

Research output: Contribution to journalArticle

@article{4cebe1d812ca40728757a701a625773b,
title = "Shrinkage forces due to polymerization of light-cured dental composite resin in cavities",
abstract = "A new method has been developed for determining shrinkage forces due to polymerization of light-cured dental composite resin in artificial cylindrical cavities. The cavities were fabricated in stainless steel plates, and shrinkage forces were measured using a load cell inserted from the rear of the plate in place of the floor of the cavity. The cavities were 3 mm in diameter, and depths varied from 0.5 to 3.5 mm to study the effect of light intensity. Cavities were filled with a composite resin after being prepared with a bonding agent and were then irradiated for 20 s with a light-curing unit at a power of 300 mW/cm2. To study the effects of boundaries, two conditions were employed: a free surface condition without any restriction on the top surface of the cavity, and a constrained surface condition in which the top surface of the resin was bonded to a 1 mm thick transparent polymethyl methacrylate (PMMA) plate. The shrinkage forces were measured as functions of time and the cavity depth, and the following results were obtained. For both conditions, the force increased with time, mostly during the irradiation stage (20 s), and then increased slightly after the irradiation. The force measured at 300 s increased gradually with the cavity depth and exhibited a maximum value before decreasing gradually. The cavities with constrained surfaces yielded much greater shrinkage forces for any given cavity depth than those with free surface conditions.",
author = "Kazuo Arakawa",
year = "2010",
month = "12",
day = "1",
doi = "10.1016/j.polymertesting.2010.09.008",
language = "English",
volume = "29",
pages = "1052--1056",
journal = "Polymer Testing",
issn = "0142-9418",
publisher = "Elsevier Limited",
number = "8",

}

TY - JOUR

T1 - Shrinkage forces due to polymerization of light-cured dental composite resin in cavities

AU - Arakawa, Kazuo

PY - 2010/12/1

Y1 - 2010/12/1

N2 - A new method has been developed for determining shrinkage forces due to polymerization of light-cured dental composite resin in artificial cylindrical cavities. The cavities were fabricated in stainless steel plates, and shrinkage forces were measured using a load cell inserted from the rear of the plate in place of the floor of the cavity. The cavities were 3 mm in diameter, and depths varied from 0.5 to 3.5 mm to study the effect of light intensity. Cavities were filled with a composite resin after being prepared with a bonding agent and were then irradiated for 20 s with a light-curing unit at a power of 300 mW/cm2. To study the effects of boundaries, two conditions were employed: a free surface condition without any restriction on the top surface of the cavity, and a constrained surface condition in which the top surface of the resin was bonded to a 1 mm thick transparent polymethyl methacrylate (PMMA) plate. The shrinkage forces were measured as functions of time and the cavity depth, and the following results were obtained. For both conditions, the force increased with time, mostly during the irradiation stage (20 s), and then increased slightly after the irradiation. The force measured at 300 s increased gradually with the cavity depth and exhibited a maximum value before decreasing gradually. The cavities with constrained surfaces yielded much greater shrinkage forces for any given cavity depth than those with free surface conditions.

AB - A new method has been developed for determining shrinkage forces due to polymerization of light-cured dental composite resin in artificial cylindrical cavities. The cavities were fabricated in stainless steel plates, and shrinkage forces were measured using a load cell inserted from the rear of the plate in place of the floor of the cavity. The cavities were 3 mm in diameter, and depths varied from 0.5 to 3.5 mm to study the effect of light intensity. Cavities were filled with a composite resin after being prepared with a bonding agent and were then irradiated for 20 s with a light-curing unit at a power of 300 mW/cm2. To study the effects of boundaries, two conditions were employed: a free surface condition without any restriction on the top surface of the cavity, and a constrained surface condition in which the top surface of the resin was bonded to a 1 mm thick transparent polymethyl methacrylate (PMMA) plate. The shrinkage forces were measured as functions of time and the cavity depth, and the following results were obtained. For both conditions, the force increased with time, mostly during the irradiation stage (20 s), and then increased slightly after the irradiation. The force measured at 300 s increased gradually with the cavity depth and exhibited a maximum value before decreasing gradually. The cavities with constrained surfaces yielded much greater shrinkage forces for any given cavity depth than those with free surface conditions.

UR - http://www.scopus.com/inward/record.url?scp=77958574981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77958574981&partnerID=8YFLogxK

U2 - 10.1016/j.polymertesting.2010.09.008

DO - 10.1016/j.polymertesting.2010.09.008

M3 - Article

AN - SCOPUS:77958574981

VL - 29

SP - 1052

EP - 1056

JO - Polymer Testing

JF - Polymer Testing

SN - 0142-9418

IS - 8

ER -