Abstract
The time-of-flight-type neutral particle analyzer, which was able of horizontal continuous scanning during long discharges, was operated in large helical device. Experiments for the comparison between the co- and counter neutral beam injection were performed. It was found that the particle with large pitch angle was lost in the counter injection from the spectrum of the pitch angle distribution of the neutral particles.
Original language | English |
---|---|
Pages (from-to) | 1878-1882 |
Number of pages | 5 |
Journal | Review of Scientific Instruments |
Volume | 74 |
Issue number | 3 II |
DOIs | |
Publication status | Published - Mar 2003 |
Externally published | Yes |
Event | Proceedings of the 14th Topical Conference on High - Temperature Plasma Diagnostics - Madison, WI, United States Duration: Jul 8 2002 → Jul 11 2002 |
All Science Journal Classification (ASJC) codes
- Instrumentation