乾式パネルを用いた大垂壁を有する伝統木造軸組架構の静的加力実験

Translated title of the contribution: STATIC LOADING TESTS FOR TIMBER FRAMES WITH LARGE HANGING WALLS USING DRY-MUD PANELS

澁谷 悦敬, 南部 恭広, 大村 早紀, 横部 達也, 杉野 未奈, 林 康裕

Research output: Contribution to journalArticlepeer-review

Abstract

Static loading tests for timber frames with large hanging walls using dry-mud panels were conducted. Following results were obtained. 1) Failure mechanism of the frames is roughly classified into damage of the walls and breakage of the columns. If the columns of the frames were broken, bearing force of the frames is smaller. 2) If the columns of the frames were not broken, restoring force characteristics are varied by specification of the frames. 3) If the side of the columns in which was inserted the <i>Sashigamoi</i> was pulled, the columns are broken at about the half of the flexural strength.
Translated title of the contributionSTATIC LOADING TESTS FOR TIMBER FRAMES WITH LARGE HANGING WALLS USING DRY-MUD PANELS
Original languageJapanese
Pages (from-to)1031-1036
Number of pages6
JournalAIJ Journal of Technology and Design
Volume21
Issue number49
DOIs
Publication statusPublished - 2015

Fingerprint Dive into the research topics of 'STATIC LOADING TESTS FOR TIMBER FRAMES WITH LARGE HANGING WALLS USING DRY-MUD PANELS'. Together they form a unique fingerprint.

Cite this