Abstract
Steady-state ion cyclotron range of frequency (ICRF) heating technologies were developed to heat plasma for >30 min in a large helical device (LHD). Steady-state-operation tests of high voltages up to 40 kV0p for >30 min were carried out on radio-frequency vacuum feedthroughs and a coaxial transmission line in a test set. The performance of the feedthroughs and transmission line exceeded the specifications for steady-state heating in the LHD.
Original language | English |
---|---|
Pages (from-to) | 297-308 |
Number of pages | 12 |
Journal | Fusion Technology |
Volume | 35 |
Issue number | 3 |
DOIs | |
Publication status | Published - 1999 |
Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Engineering(all)