Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator

M. Yoshioka, M. Ueyama, Y. Koba, Y. Nakamura, T. Kajimoto, D. Moriguchi, Yusuke Uozumi, Nobuhiro Shigyo, D. Sato, T. Sanami, M. Takada

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

We have studied pulse shape discrimination of sub-MeV neutron from spallation nuclear reactions. Neutron measurements were carried out with a 2-inch NE213 scintillator viewed by a phototube (HAMAMATSU H1949) for the carbon-carbon reaction at 290 MeV/n. Neuron energies were mea- sured with the TOF technique by using a timing pick-up plastic scintillator. Output signals of detectors were digitized and stored with a digitizer (Acqiris DC282). The digital pulse shape dis- crimination (DPSD) has been investigated through comparison between three different analyzing algorithms. Effects on the neutron-gamma (n/g) discrimination were also investigated after the subtraction of background and abnormal events. Moreover, in order to realize better n/g discrimi- nation the detector system was cooled down to about zero degrees centigrade by Peltier devices to suppress the dark current of the phototube which would be the main cause distorting pulse shapes. Experimental studies were made in terms of the temperature dependence of detector performance including pulse shape.

Original languageEnglish
Pages (from-to)1971-1974
Number of pages4
JournalJournal of the Korean Physical Society
Volume59
Issue number23
DOIs
Publication statusPublished - Aug 1 2011

Fingerprint

scintillation counters
discrimination
gamma rays
phototubes
neutrons
liquids
pulses
detectors
carbon
analog to digital converters
spallation
dark current
neurons
subtraction
nuclear reactions
plastics
time measurement
temperature dependence
causes
output

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

Cite this

Yoshioka, M., Ueyama, M., Koba, Y., Nakamura, Y., Kajimoto, T., Moriguchi, D., ... Takada, M. (2011). Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator. Journal of the Korean Physical Society, 59(23), 1971-1974. https://doi.org/10.3938/jkps.59.1971

Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator. / Yoshioka, M.; Ueyama, M.; Koba, Y.; Nakamura, Y.; Kajimoto, T.; Moriguchi, D.; Uozumi, Yusuke; Shigyo, Nobuhiro; Sato, D.; Sanami, T.; Takada, M.

In: Journal of the Korean Physical Society, Vol. 59, No. 23, 01.08.2011, p. 1971-1974.

Research output: Contribution to journalArticle

Yoshioka, M, Ueyama, M, Koba, Y, Nakamura, Y, Kajimoto, T, Moriguchi, D, Uozumi, Y, Shigyo, N, Sato, D, Sanami, T & Takada, M 2011, 'Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator', Journal of the Korean Physical Society, vol. 59, no. 23, pp. 1971-1974. https://doi.org/10.3938/jkps.59.1971
Yoshioka, M. ; Ueyama, M. ; Koba, Y. ; Nakamura, Y. ; Kajimoto, T. ; Moriguchi, D. ; Uozumi, Yusuke ; Shigyo, Nobuhiro ; Sato, D. ; Sanami, T. ; Takada, M. / Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator. In: Journal of the Korean Physical Society. 2011 ; Vol. 59, No. 23. pp. 1971-1974.
@article{486a6dd00e2f494b9f91d3bd8aabc19d,
title = "Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator",
abstract = "We have studied pulse shape discrimination of sub-MeV neutron from spallation nuclear reactions. Neutron measurements were carried out with a 2-inch NE213 scintillator viewed by a phototube (HAMAMATSU H1949) for the carbon-carbon reaction at 290 MeV/n. Neuron energies were mea- sured with the TOF technique by using a timing pick-up plastic scintillator. Output signals of detectors were digitized and stored with a digitizer (Acqiris DC282). The digital pulse shape dis- crimination (DPSD) has been investigated through comparison between three different analyzing algorithms. Effects on the neutron-gamma (n/g) discrimination were also investigated after the subtraction of background and abnormal events. Moreover, in order to realize better n/g discrimi- nation the detector system was cooled down to about zero degrees centigrade by Peltier devices to suppress the dark current of the phototube which would be the main cause distorting pulse shapes. Experimental studies were made in terms of the temperature dependence of detector performance including pulse shape.",
author = "M. Yoshioka and M. Ueyama and Y. Koba and Y. Nakamura and T. Kajimoto and D. Moriguchi and Yusuke Uozumi and Nobuhiro Shigyo and D. Sato and T. Sanami and M. Takada",
year = "2011",
month = "8",
day = "1",
doi = "10.3938/jkps.59.1971",
language = "English",
volume = "59",
pages = "1971--1974",
journal = "Journal of the Korean Physical Society",
issn = "0374-4884",
publisher = "Korean Physical Society",
number = "23",

}

TY - JOUR

T1 - Study of pulse shape discrimination of sub-MeV neutrons from gamma-rays with liquid scintillator

AU - Yoshioka, M.

AU - Ueyama, M.

AU - Koba, Y.

AU - Nakamura, Y.

AU - Kajimoto, T.

AU - Moriguchi, D.

AU - Uozumi, Yusuke

AU - Shigyo, Nobuhiro

AU - Sato, D.

AU - Sanami, T.

AU - Takada, M.

PY - 2011/8/1

Y1 - 2011/8/1

N2 - We have studied pulse shape discrimination of sub-MeV neutron from spallation nuclear reactions. Neutron measurements were carried out with a 2-inch NE213 scintillator viewed by a phototube (HAMAMATSU H1949) for the carbon-carbon reaction at 290 MeV/n. Neuron energies were mea- sured with the TOF technique by using a timing pick-up plastic scintillator. Output signals of detectors were digitized and stored with a digitizer (Acqiris DC282). The digital pulse shape dis- crimination (DPSD) has been investigated through comparison between three different analyzing algorithms. Effects on the neutron-gamma (n/g) discrimination were also investigated after the subtraction of background and abnormal events. Moreover, in order to realize better n/g discrimi- nation the detector system was cooled down to about zero degrees centigrade by Peltier devices to suppress the dark current of the phototube which would be the main cause distorting pulse shapes. Experimental studies were made in terms of the temperature dependence of detector performance including pulse shape.

AB - We have studied pulse shape discrimination of sub-MeV neutron from spallation nuclear reactions. Neutron measurements were carried out with a 2-inch NE213 scintillator viewed by a phototube (HAMAMATSU H1949) for the carbon-carbon reaction at 290 MeV/n. Neuron energies were mea- sured with the TOF technique by using a timing pick-up plastic scintillator. Output signals of detectors were digitized and stored with a digitizer (Acqiris DC282). The digital pulse shape dis- crimination (DPSD) has been investigated through comparison between three different analyzing algorithms. Effects on the neutron-gamma (n/g) discrimination were also investigated after the subtraction of background and abnormal events. Moreover, in order to realize better n/g discrimi- nation the detector system was cooled down to about zero degrees centigrade by Peltier devices to suppress the dark current of the phototube which would be the main cause distorting pulse shapes. Experimental studies were made in terms of the temperature dependence of detector performance including pulse shape.

UR - http://www.scopus.com/inward/record.url?scp=80052204900&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052204900&partnerID=8YFLogxK

U2 - 10.3938/jkps.59.1971

DO - 10.3938/jkps.59.1971

M3 - Article

VL - 59

SP - 1971

EP - 1974

JO - Journal of the Korean Physical Society

JF - Journal of the Korean Physical Society

SN - 0374-4884

IS - 23

ER -