Study on characteristic parameters of a new converter transformer for HVDC systems

Yong Li, Longfu Luo, Christian Rehtanz, Kazuo Nakamura, Jiazhu Xu, Fusheng Liu

Research output: Contribution to journalArticle

51 Citations (Scopus)

Abstract

Different from the traditional converter transformer and ac passive filtering method, this paper presents a new converter transformer and a corresponding inductive filtering method for HVDC systems. Based on this, characteristic parameters of the new converter transformer are studied in detail by theoretical analysis, simulation, calculation, and experimental verification. By deducing voltage relation, the constraint condition of the turn ratio is obtained, which can satisfy the demand of a 12-pulse converter in HVDC systems. By deducing current relations, the characteristics of the fundamental and the harmonic currents in the winding are obtained. According to the established operation equations, the simple but practical calculation methods for the short-circuit impedance and the rated capacity are proposed. Then, the change characteristic of the short-circuit impedance is analyzed and calculated. The detailed simulation and test results verified the correctness of the aforementioned theoretical analysis and calculation.

Original languageEnglish
Pages (from-to)2125-2131
Number of pages7
JournalIEEE Transactions on Power Delivery
Volume24
Issue number4
DOIs
Publication statusPublished - Aug 4 2009

Fingerprint

Short circuit currents
Electric potential

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

Study on characteristic parameters of a new converter transformer for HVDC systems. / Li, Yong; Luo, Longfu; Rehtanz, Christian; Nakamura, Kazuo; Xu, Jiazhu; Liu, Fusheng.

In: IEEE Transactions on Power Delivery, Vol. 24, No. 4, 04.08.2009, p. 2125-2131.

Research output: Contribution to journalArticle

Li, Yong ; Luo, Longfu ; Rehtanz, Christian ; Nakamura, Kazuo ; Xu, Jiazhu ; Liu, Fusheng. / Study on characteristic parameters of a new converter transformer for HVDC systems. In: IEEE Transactions on Power Delivery. 2009 ; Vol. 24, No. 4. pp. 2125-2131.
@article{660194f3c489407db84aecd5cc564ae5,
title = "Study on characteristic parameters of a new converter transformer for HVDC systems",
abstract = "Different from the traditional converter transformer and ac passive filtering method, this paper presents a new converter transformer and a corresponding inductive filtering method for HVDC systems. Based on this, characteristic parameters of the new converter transformer are studied in detail by theoretical analysis, simulation, calculation, and experimental verification. By deducing voltage relation, the constraint condition of the turn ratio is obtained, which can satisfy the demand of a 12-pulse converter in HVDC systems. By deducing current relations, the characteristics of the fundamental and the harmonic currents in the winding are obtained. According to the established operation equations, the simple but practical calculation methods for the short-circuit impedance and the rated capacity are proposed. Then, the change characteristic of the short-circuit impedance is analyzed and calculated. The detailed simulation and test results verified the correctness of the aforementioned theoretical analysis and calculation.",
author = "Yong Li and Longfu Luo and Christian Rehtanz and Kazuo Nakamura and Jiazhu Xu and Fusheng Liu",
year = "2009",
month = "8",
day = "4",
doi = "10.1109/TPWRD.2009.2021033",
language = "English",
volume = "24",
pages = "2125--2131",
journal = "IEEE Transactions on Power Delivery",
issn = "0885-8977",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "4",

}

TY - JOUR

T1 - Study on characteristic parameters of a new converter transformer for HVDC systems

AU - Li, Yong

AU - Luo, Longfu

AU - Rehtanz, Christian

AU - Nakamura, Kazuo

AU - Xu, Jiazhu

AU - Liu, Fusheng

PY - 2009/8/4

Y1 - 2009/8/4

N2 - Different from the traditional converter transformer and ac passive filtering method, this paper presents a new converter transformer and a corresponding inductive filtering method for HVDC systems. Based on this, characteristic parameters of the new converter transformer are studied in detail by theoretical analysis, simulation, calculation, and experimental verification. By deducing voltage relation, the constraint condition of the turn ratio is obtained, which can satisfy the demand of a 12-pulse converter in HVDC systems. By deducing current relations, the characteristics of the fundamental and the harmonic currents in the winding are obtained. According to the established operation equations, the simple but practical calculation methods for the short-circuit impedance and the rated capacity are proposed. Then, the change characteristic of the short-circuit impedance is analyzed and calculated. The detailed simulation and test results verified the correctness of the aforementioned theoretical analysis and calculation.

AB - Different from the traditional converter transformer and ac passive filtering method, this paper presents a new converter transformer and a corresponding inductive filtering method for HVDC systems. Based on this, characteristic parameters of the new converter transformer are studied in detail by theoretical analysis, simulation, calculation, and experimental verification. By deducing voltage relation, the constraint condition of the turn ratio is obtained, which can satisfy the demand of a 12-pulse converter in HVDC systems. By deducing current relations, the characteristics of the fundamental and the harmonic currents in the winding are obtained. According to the established operation equations, the simple but practical calculation methods for the short-circuit impedance and the rated capacity are proposed. Then, the change characteristic of the short-circuit impedance is analyzed and calculated. The detailed simulation and test results verified the correctness of the aforementioned theoretical analysis and calculation.

UR - http://www.scopus.com/inward/record.url?scp=70350263404&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350263404&partnerID=8YFLogxK

U2 - 10.1109/TPWRD.2009.2021033

DO - 10.1109/TPWRD.2009.2021033

M3 - Article

AN - SCOPUS:70350263404

VL - 24

SP - 2125

EP - 2131

JO - IEEE Transactions on Power Delivery

JF - IEEE Transactions on Power Delivery

SN - 0885-8977

IS - 4

ER -