SU‐GG‐J‐44: Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy

A. Mizoguchi, Hidetaka Arimura, S. Yoshidome, M. Tachibana, Yoshiyuki Shioyama, S. Anai, K. Nakamura, Hiroshi Honda, Y. Higashida, F. Toyofuku, Masafumi Ohki, H. Hirata

Research output: Contribution to journalArticle

Abstract

Purpose: Lateral scatter kernels (LSKs) of an electronic portal imaging device (EPID) and a water equivalent phantom are essential data for estimating the three‐dimensional dose distributions in lung cancer patients who receive stereotactic body radiotherapy. The LSKs are used for converting portal images to portal dose images. The purpose of this study was to investigate a method of estimating LSKs of the EPID and water equivalent phantom, and then compare the LSKs between experimental measurements and the Monte Carlo (MC) method. Method and Materials: The experimental LSKs were derived from the differentiation of the signal (mean pixel value or absorbed dose) as a function of equivalent circular radius of irradiation area. Mean pixel values in a region of interest of the EPID and absorbed doses in the water equivalent phantom were measured for estimating the LSKs of the EPID and water equivalent phantom, respectively, by changing the irradiation area of 3×3 to 20×20 cm2. For evaluation of the experimental method, the theoretical LSKs were obtained based on the Monte Carlo method by simulating the same geometry of the experimental set‐up including the EPID and water equivalent phantom. Two x‐ray energies of 6 and 10 MV were employed respectively, at a medical linear accelerator in conjunction with an EPID. Results: The experimental method overestimated the LSKs of the EPID and water equivalent phantom compared with those of the Monte Carlo simulation method. The full width half maximum values at 6 and 10 MV of the theoretical LSKs were 0.166 and 0.193 cm for the EPID, respectively, and 0.177 and 0.211 cm for the water equivalent phantom, respectively. Conclusion: We should continue to investigate the experimental and theoretical methods for estimation of LSKs of the EPID and water equivalent phantom for dose verification in stereotactic lung radiotherapy.

Original languageEnglish
Number of pages1
JournalMedical Physics
Volume37
Issue number6
DOIs
Publication statusPublished - Jan 1 2010

Fingerprint

Radiotherapy
Equipment and Supplies
Lung
Water
Monte Carlo Method
Particle Accelerators
Radiosurgery
Lung Neoplasms
X-Rays

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐GG‐J‐44 : Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy. / Mizoguchi, A.; Arimura, Hidetaka; Yoshidome, S.; Tachibana, M.; Shioyama, Yoshiyuki; Anai, S.; Nakamura, K.; Honda, Hiroshi; Higashida, Y.; Toyofuku, F.; Ohki, Masafumi; Hirata, H.

In: Medical Physics, Vol. 37, No. 6, 01.01.2010.

Research output: Contribution to journalArticle

Mizoguchi, A, Arimura, H, Yoshidome, S, Tachibana, M, Shioyama, Y, Anai, S, Nakamura, K, Honda, H, Higashida, Y, Toyofuku, F, Ohki, M & Hirata, H 2010, 'SU‐GG‐J‐44: Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy', Medical Physics, vol. 37, no. 6. https://doi.org/10.1118/1.3468268
Mizoguchi, A. ; Arimura, Hidetaka ; Yoshidome, S. ; Tachibana, M. ; Shioyama, Yoshiyuki ; Anai, S. ; Nakamura, K. ; Honda, Hiroshi ; Higashida, Y. ; Toyofuku, F. ; Ohki, Masafumi ; Hirata, H. / SU‐GG‐J‐44 : Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy. In: Medical Physics. 2010 ; Vol. 37, No. 6.
@article{3cdc04efb8c74261a25b14d17dcdbf0c,
title = "SU‐GG‐J‐44: Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy",
abstract = "Purpose: Lateral scatter kernels (LSKs) of an electronic portal imaging device (EPID) and a water equivalent phantom are essential data for estimating the three‐dimensional dose distributions in lung cancer patients who receive stereotactic body radiotherapy. The LSKs are used for converting portal images to portal dose images. The purpose of this study was to investigate a method of estimating LSKs of the EPID and water equivalent phantom, and then compare the LSKs between experimental measurements and the Monte Carlo (MC) method. Method and Materials: The experimental LSKs were derived from the differentiation of the signal (mean pixel value or absorbed dose) as a function of equivalent circular radius of irradiation area. Mean pixel values in a region of interest of the EPID and absorbed doses in the water equivalent phantom were measured for estimating the LSKs of the EPID and water equivalent phantom, respectively, by changing the irradiation area of 3×3 to 20×20 cm2. For evaluation of the experimental method, the theoretical LSKs were obtained based on the Monte Carlo method by simulating the same geometry of the experimental set‐up including the EPID and water equivalent phantom. Two x‐ray energies of 6 and 10 MV were employed respectively, at a medical linear accelerator in conjunction with an EPID. Results: The experimental method overestimated the LSKs of the EPID and water equivalent phantom compared with those of the Monte Carlo simulation method. The full width half maximum values at 6 and 10 MV of the theoretical LSKs were 0.166 and 0.193 cm for the EPID, respectively, and 0.177 and 0.211 cm for the water equivalent phantom, respectively. Conclusion: We should continue to investigate the experimental and theoretical methods for estimation of LSKs of the EPID and water equivalent phantom for dose verification in stereotactic lung radiotherapy.",
author = "A. Mizoguchi and Hidetaka Arimura and S. Yoshidome and M. Tachibana and Yoshiyuki Shioyama and S. Anai and K. Nakamura and Hiroshi Honda and Y. Higashida and F. Toyofuku and Masafumi Ohki and H. Hirata",
year = "2010",
month = "1",
day = "1",
doi = "10.1118/1.3468268",
language = "English",
volume = "37",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐GG‐J‐44

T2 - Estimation of Lateral Scatter Kernels in EPID and Water Equivalent Phantom for Dose Verification in Stereotactic Lung Radiotherapy

AU - Mizoguchi, A.

AU - Arimura, Hidetaka

AU - Yoshidome, S.

AU - Tachibana, M.

AU - Shioyama, Yoshiyuki

AU - Anai, S.

AU - Nakamura, K.

AU - Honda, Hiroshi

AU - Higashida, Y.

AU - Toyofuku, F.

AU - Ohki, Masafumi

AU - Hirata, H.

PY - 2010/1/1

Y1 - 2010/1/1

N2 - Purpose: Lateral scatter kernels (LSKs) of an electronic portal imaging device (EPID) and a water equivalent phantom are essential data for estimating the three‐dimensional dose distributions in lung cancer patients who receive stereotactic body radiotherapy. The LSKs are used for converting portal images to portal dose images. The purpose of this study was to investigate a method of estimating LSKs of the EPID and water equivalent phantom, and then compare the LSKs between experimental measurements and the Monte Carlo (MC) method. Method and Materials: The experimental LSKs were derived from the differentiation of the signal (mean pixel value or absorbed dose) as a function of equivalent circular radius of irradiation area. Mean pixel values in a region of interest of the EPID and absorbed doses in the water equivalent phantom were measured for estimating the LSKs of the EPID and water equivalent phantom, respectively, by changing the irradiation area of 3×3 to 20×20 cm2. For evaluation of the experimental method, the theoretical LSKs were obtained based on the Monte Carlo method by simulating the same geometry of the experimental set‐up including the EPID and water equivalent phantom. Two x‐ray energies of 6 and 10 MV were employed respectively, at a medical linear accelerator in conjunction with an EPID. Results: The experimental method overestimated the LSKs of the EPID and water equivalent phantom compared with those of the Monte Carlo simulation method. The full width half maximum values at 6 and 10 MV of the theoretical LSKs were 0.166 and 0.193 cm for the EPID, respectively, and 0.177 and 0.211 cm for the water equivalent phantom, respectively. Conclusion: We should continue to investigate the experimental and theoretical methods for estimation of LSKs of the EPID and water equivalent phantom for dose verification in stereotactic lung radiotherapy.

AB - Purpose: Lateral scatter kernels (LSKs) of an electronic portal imaging device (EPID) and a water equivalent phantom are essential data for estimating the three‐dimensional dose distributions in lung cancer patients who receive stereotactic body radiotherapy. The LSKs are used for converting portal images to portal dose images. The purpose of this study was to investigate a method of estimating LSKs of the EPID and water equivalent phantom, and then compare the LSKs between experimental measurements and the Monte Carlo (MC) method. Method and Materials: The experimental LSKs were derived from the differentiation of the signal (mean pixel value or absorbed dose) as a function of equivalent circular radius of irradiation area. Mean pixel values in a region of interest of the EPID and absorbed doses in the water equivalent phantom were measured for estimating the LSKs of the EPID and water equivalent phantom, respectively, by changing the irradiation area of 3×3 to 20×20 cm2. For evaluation of the experimental method, the theoretical LSKs were obtained based on the Monte Carlo method by simulating the same geometry of the experimental set‐up including the EPID and water equivalent phantom. Two x‐ray energies of 6 and 10 MV were employed respectively, at a medical linear accelerator in conjunction with an EPID. Results: The experimental method overestimated the LSKs of the EPID and water equivalent phantom compared with those of the Monte Carlo simulation method. The full width half maximum values at 6 and 10 MV of the theoretical LSKs were 0.166 and 0.193 cm for the EPID, respectively, and 0.177 and 0.211 cm for the water equivalent phantom, respectively. Conclusion: We should continue to investigate the experimental and theoretical methods for estimation of LSKs of the EPID and water equivalent phantom for dose verification in stereotactic lung radiotherapy.

UR - http://www.scopus.com/inward/record.url?scp=85024805731&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024805731&partnerID=8YFLogxK

U2 - 10.1118/1.3468268

DO - 10.1118/1.3468268

M3 - Article

AN - SCOPUS:85024805731

VL - 37

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -