Sweep-rate dependences of losses in aluminum-stabilized superconducting conductors for the Large Helical Device

F. Sumiyoshi, Y. Kanai, T. Kawashima, M. Iwakuma, T. Mito, K. Takahata, N. Yanagi, J. Yamamoto

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We measured the frequency characteristics of ac losses in the aluminum-stabilized superconducting conductor for the helical coil system of the Large Helical Device (LHD) project, in order to clarify the dependence of the loss on the sweep rate of the poloidal field. In our experiment, a straight and short conductor of about 50 cm long was used as a sample. The sample was subjected to the ac ripple field superposed on the bias field. The data of the ac loss observed in the frequency range from 0.1 to 100 Hz have two peaks just as our analysis predicted. The peak at the lower frequency is the critical frequency related to the inter-strand coupling time constant τc. The other peak at the higher frequency is the skin frequency of the normal metal around the strand bundle in the conductor. The lower frequency peak mainly shifts according to the cabling condition of the strand bundle. Under the operating condition of the LHD corresponding to 0.1 Hz, the loss can be decreased as τc increases. It is very different from the common design concept. This result suggests that it is necessary to grasp the sweep-rate dependence of the loss in the conductor in order to optimize its structure from the low-loss point of view.

Original languageEnglish
Pages (from-to)371-376
Number of pages6
JournalFusion Engineering and Design
Volume20
Issue numberC
DOIs
Publication statusPublished - Jan 1993

Fingerprint

Aluminum
Skin
Metals
Experiments

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Nuclear Energy and Engineering
  • Materials Science(all)
  • Mechanical Engineering

Cite this

Sweep-rate dependences of losses in aluminum-stabilized superconducting conductors for the Large Helical Device. / Sumiyoshi, F.; Kanai, Y.; Kawashima, T.; Iwakuma, M.; Mito, T.; Takahata, K.; Yanagi, N.; Yamamoto, J.

In: Fusion Engineering and Design, Vol. 20, No. C, 01.1993, p. 371-376.

Research output: Contribution to journalArticle

Sumiyoshi, F. ; Kanai, Y. ; Kawashima, T. ; Iwakuma, M. ; Mito, T. ; Takahata, K. ; Yanagi, N. ; Yamamoto, J. / Sweep-rate dependences of losses in aluminum-stabilized superconducting conductors for the Large Helical Device. In: Fusion Engineering and Design. 1993 ; Vol. 20, No. C. pp. 371-376.
@article{def9e2218b0748808c8bdb9410da506c,
title = "Sweep-rate dependences of losses in aluminum-stabilized superconducting conductors for the Large Helical Device",
abstract = "We measured the frequency characteristics of ac losses in the aluminum-stabilized superconducting conductor for the helical coil system of the Large Helical Device (LHD) project, in order to clarify the dependence of the loss on the sweep rate of the poloidal field. In our experiment, a straight and short conductor of about 50 cm long was used as a sample. The sample was subjected to the ac ripple field superposed on the bias field. The data of the ac loss observed in the frequency range from 0.1 to 100 Hz have two peaks just as our analysis predicted. The peak at the lower frequency is the critical frequency related to the inter-strand coupling time constant τc. The other peak at the higher frequency is the skin frequency of the normal metal around the strand bundle in the conductor. The lower frequency peak mainly shifts according to the cabling condition of the strand bundle. Under the operating condition of the LHD corresponding to 0.1 Hz, the loss can be decreased as τc increases. It is very different from the common design concept. This result suggests that it is necessary to grasp the sweep-rate dependence of the loss in the conductor in order to optimize its structure from the low-loss point of view.",
author = "F. Sumiyoshi and Y. Kanai and T. Kawashima and M. Iwakuma and T. Mito and K. Takahata and N. Yanagi and J. Yamamoto",
year = "1993",
month = "1",
doi = "10.1016/0920-3796(93)90067-R",
language = "English",
volume = "20",
pages = "371--376",
journal = "Fusion Engineering and Design",
issn = "0920-3796",
publisher = "Elsevier BV",
number = "C",

}

TY - JOUR

T1 - Sweep-rate dependences of losses in aluminum-stabilized superconducting conductors for the Large Helical Device

AU - Sumiyoshi, F.

AU - Kanai, Y.

AU - Kawashima, T.

AU - Iwakuma, M.

AU - Mito, T.

AU - Takahata, K.

AU - Yanagi, N.

AU - Yamamoto, J.

PY - 1993/1

Y1 - 1993/1

N2 - We measured the frequency characteristics of ac losses in the aluminum-stabilized superconducting conductor for the helical coil system of the Large Helical Device (LHD) project, in order to clarify the dependence of the loss on the sweep rate of the poloidal field. In our experiment, a straight and short conductor of about 50 cm long was used as a sample. The sample was subjected to the ac ripple field superposed on the bias field. The data of the ac loss observed in the frequency range from 0.1 to 100 Hz have two peaks just as our analysis predicted. The peak at the lower frequency is the critical frequency related to the inter-strand coupling time constant τc. The other peak at the higher frequency is the skin frequency of the normal metal around the strand bundle in the conductor. The lower frequency peak mainly shifts according to the cabling condition of the strand bundle. Under the operating condition of the LHD corresponding to 0.1 Hz, the loss can be decreased as τc increases. It is very different from the common design concept. This result suggests that it is necessary to grasp the sweep-rate dependence of the loss in the conductor in order to optimize its structure from the low-loss point of view.

AB - We measured the frequency characteristics of ac losses in the aluminum-stabilized superconducting conductor for the helical coil system of the Large Helical Device (LHD) project, in order to clarify the dependence of the loss on the sweep rate of the poloidal field. In our experiment, a straight and short conductor of about 50 cm long was used as a sample. The sample was subjected to the ac ripple field superposed on the bias field. The data of the ac loss observed in the frequency range from 0.1 to 100 Hz have two peaks just as our analysis predicted. The peak at the lower frequency is the critical frequency related to the inter-strand coupling time constant τc. The other peak at the higher frequency is the skin frequency of the normal metal around the strand bundle in the conductor. The lower frequency peak mainly shifts according to the cabling condition of the strand bundle. Under the operating condition of the LHD corresponding to 0.1 Hz, the loss can be decreased as τc increases. It is very different from the common design concept. This result suggests that it is necessary to grasp the sweep-rate dependence of the loss in the conductor in order to optimize its structure from the low-loss point of view.

UR - http://www.scopus.com/inward/record.url?scp=0043033156&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0043033156&partnerID=8YFLogxK

U2 - 10.1016/0920-3796(93)90067-R

DO - 10.1016/0920-3796(93)90067-R

M3 - Article

AN - SCOPUS:0043033156

VL - 20

SP - 371

EP - 376

JO - Fusion Engineering and Design

JF - Fusion Engineering and Design

SN - 0920-3796

IS - C

ER -