The design and performance of beamline BL15 at SAGA light source

T. Okajima, Y. Chikaura, Y. Suzuki, M. Tabata, Y. Soejima, K. Hara, R. Haruki, K. Nagata, N. Hiramatsu, A. Kohno, M. Takumi, H. Setoyama, D. Yoshimura

Research output: Chapter in Book/Report/Conference proceedingConference contribution

6 Citations (Scopus)

Abstract

A new X-ray beamline has been designed and constructed at SAGA Light Source. The beamline, named BL15, covers an energy range from 2.1 to 14.2 keV and is intended for the characterization of various materials developed for industrial purposes. The beamline has an experimental station for the performance of several experiments: e.g. X-ray absorption fine structure (XAFS) measurement; high resolution diffractometry; topographic imaging; energy-dispersive four-circle diffractometry. The photon flux passing through a receiving slit at XAFS measurement position is more than 1 × 10 11 photons/sec with focusing mirror in the energy range of less than 8keV. The XANES spectra measurements of Cu and Ti K-edge show that the beamline has a good energy resolution.

Original languageEnglish
Title of host publicationSYNCHROTRON RADIATION INSTRUMENTATION
Subtitle of host publicationNinth International Conference on Synchrotron Radiation Instrumentation
Pages820-823
Number of pages4
DOIs
Publication statusPublished - Mar 26 2007
EventSYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation - Daegu, Korea, Republic of
Duration: May 28 2006Jun 28 2006

Publication series

NameAIP Conference Proceedings
Volume879
ISSN (Print)0094-243X
ISSN (Electronic)1551-7616

Other

OtherSYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation
CountryKorea, Republic of
CityDaegu
Period5/28/066/28/06

Fingerprint

light sources
X-radiation
energy
fine structure
x rays
photons
slits
stations
image analysis
mirrors
high resolution
experiment

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

Cite this

Okajima, T., Chikaura, Y., Suzuki, Y., Tabata, M., Soejima, Y., Hara, K., ... Yoshimura, D. (2007). The design and performance of beamline BL15 at SAGA light source. In SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation (pp. 820-823). (AIP Conference Proceedings; Vol. 879). https://doi.org/10.1063/1.2436186

The design and performance of beamline BL15 at SAGA light source. / Okajima, T.; Chikaura, Y.; Suzuki, Y.; Tabata, M.; Soejima, Y.; Hara, K.; Haruki, R.; Nagata, K.; Hiramatsu, N.; Kohno, A.; Takumi, M.; Setoyama, H.; Yoshimura, D.

SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation. 2007. p. 820-823 (AIP Conference Proceedings; Vol. 879).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Okajima, T, Chikaura, Y, Suzuki, Y, Tabata, M, Soejima, Y, Hara, K, Haruki, R, Nagata, K, Hiramatsu, N, Kohno, A, Takumi, M, Setoyama, H & Yoshimura, D 2007, The design and performance of beamline BL15 at SAGA light source. in SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation. AIP Conference Proceedings, vol. 879, pp. 820-823, SYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation, Daegu, Korea, Republic of, 5/28/06. https://doi.org/10.1063/1.2436186
Okajima T, Chikaura Y, Suzuki Y, Tabata M, Soejima Y, Hara K et al. The design and performance of beamline BL15 at SAGA light source. In SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation. 2007. p. 820-823. (AIP Conference Proceedings). https://doi.org/10.1063/1.2436186
Okajima, T. ; Chikaura, Y. ; Suzuki, Y. ; Tabata, M. ; Soejima, Y. ; Hara, K. ; Haruki, R. ; Nagata, K. ; Hiramatsu, N. ; Kohno, A. ; Takumi, M. ; Setoyama, H. ; Yoshimura, D. / The design and performance of beamline BL15 at SAGA light source. SYNCHROTRON RADIATION INSTRUMENTATION: Ninth International Conference on Synchrotron Radiation Instrumentation. 2007. pp. 820-823 (AIP Conference Proceedings).
@inproceedings{5a895ae54ea5473da1343f777221c1d3,
title = "The design and performance of beamline BL15 at SAGA light source",
abstract = "A new X-ray beamline has been designed and constructed at SAGA Light Source. The beamline, named BL15, covers an energy range from 2.1 to 14.2 keV and is intended for the characterization of various materials developed for industrial purposes. The beamline has an experimental station for the performance of several experiments: e.g. X-ray absorption fine structure (XAFS) measurement; high resolution diffractometry; topographic imaging; energy-dispersive four-circle diffractometry. The photon flux passing through a receiving slit at XAFS measurement position is more than 1 × 10 11 photons/sec with focusing mirror in the energy range of less than 8keV. The XANES spectra measurements of Cu and Ti K-edge show that the beamline has a good energy resolution.",
author = "T. Okajima and Y. Chikaura and Y. Suzuki and M. Tabata and Y. Soejima and K. Hara and R. Haruki and K. Nagata and N. Hiramatsu and A. Kohno and M. Takumi and H. Setoyama and D. Yoshimura",
year = "2007",
month = "3",
day = "26",
doi = "10.1063/1.2436186",
language = "English",
isbn = "0735403732",
series = "AIP Conference Proceedings",
pages = "820--823",
booktitle = "SYNCHROTRON RADIATION INSTRUMENTATION",

}

TY - GEN

T1 - The design and performance of beamline BL15 at SAGA light source

AU - Okajima, T.

AU - Chikaura, Y.

AU - Suzuki, Y.

AU - Tabata, M.

AU - Soejima, Y.

AU - Hara, K.

AU - Haruki, R.

AU - Nagata, K.

AU - Hiramatsu, N.

AU - Kohno, A.

AU - Takumi, M.

AU - Setoyama, H.

AU - Yoshimura, D.

PY - 2007/3/26

Y1 - 2007/3/26

N2 - A new X-ray beamline has been designed and constructed at SAGA Light Source. The beamline, named BL15, covers an energy range from 2.1 to 14.2 keV and is intended for the characterization of various materials developed for industrial purposes. The beamline has an experimental station for the performance of several experiments: e.g. X-ray absorption fine structure (XAFS) measurement; high resolution diffractometry; topographic imaging; energy-dispersive four-circle diffractometry. The photon flux passing through a receiving slit at XAFS measurement position is more than 1 × 10 11 photons/sec with focusing mirror in the energy range of less than 8keV. The XANES spectra measurements of Cu and Ti K-edge show that the beamline has a good energy resolution.

AB - A new X-ray beamline has been designed and constructed at SAGA Light Source. The beamline, named BL15, covers an energy range from 2.1 to 14.2 keV and is intended for the characterization of various materials developed for industrial purposes. The beamline has an experimental station for the performance of several experiments: e.g. X-ray absorption fine structure (XAFS) measurement; high resolution diffractometry; topographic imaging; energy-dispersive four-circle diffractometry. The photon flux passing through a receiving slit at XAFS measurement position is more than 1 × 10 11 photons/sec with focusing mirror in the energy range of less than 8keV. The XANES spectra measurements of Cu and Ti K-edge show that the beamline has a good energy resolution.

UR - http://www.scopus.com/inward/record.url?scp=33947425529&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33947425529&partnerID=8YFLogxK

U2 - 10.1063/1.2436186

DO - 10.1063/1.2436186

M3 - Conference contribution

AN - SCOPUS:33947425529

SN - 0735403732

SN - 9780735403734

T3 - AIP Conference Proceedings

SP - 820

EP - 823

BT - SYNCHROTRON RADIATION INSTRUMENTATION

ER -