The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures

Kenoki Ohuchida, Hajime Kenmotsu, Atsuyuki Yamamoto, Kazuya Sawada, Takehito Hayami, Kenichi Morooka, Hiroshi Hoshino, Munenori Uemura, Kozo Konishi, Daisuke Yoshida, Takashi Maeda, Satoshi Ieiri, Kazuo Tanoue, Masao Tanaka, Makoto Hashizume

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Background: Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped display (3DD) system, CyberDome. Study design: In the present study, a total of 23 students volunteered. We evaluated the effects of the 3DD system on depth perception and laparoscopic procedures in comparison with the 2D, a conventional 3D (3DP) or the 2D high definition (HD) systems using seven tasks. Results: The 3DD system significantly improved depth perception and laparoscopic performance compared with the 2D system in six new tasks. We further found that the 3DD system shortened the execution time and reduced the number of errors during suturing and knot tying. The 3DD system also provided more depth perception than the 3DP and 2D HD systems. Conclusions: The novel 3DD system is a promising tool for providing depth perception with high resolution to laparoscopic surgeons.

Original languageEnglish
Pages (from-to)125-132
Number of pages8
JournalInternational Journal of Computer Assisted Radiology and Surgery
Volume4
Issue number2
DOIs
Publication statusPublished - Mar 2009

Fingerprint

Depth Perception
Domes
Depth perception
Display devices
Students

All Science Journal Classification (ASJC) codes

  • Surgery
  • Biomedical Engineering
  • Radiology Nuclear Medicine and imaging
  • Computer Vision and Pattern Recognition
  • Health Informatics
  • Computer Science Applications
  • Computer Graphics and Computer-Aided Design

Cite this

The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures. / Ohuchida, Kenoki; Kenmotsu, Hajime; Yamamoto, Atsuyuki; Sawada, Kazuya; Hayami, Takehito; Morooka, Kenichi; Hoshino, Hiroshi; Uemura, Munenori; Konishi, Kozo; Yoshida, Daisuke; Maeda, Takashi; Ieiri, Satoshi; Tanoue, Kazuo; Tanaka, Masao; Hashizume, Makoto.

In: International Journal of Computer Assisted Radiology and Surgery, Vol. 4, No. 2, 03.2009, p. 125-132.

Research output: Contribution to journalArticle

Ohuchida, K, Kenmotsu, H, Yamamoto, A, Sawada, K, Hayami, T, Morooka, K, Hoshino, H, Uemura, M, Konishi, K, Yoshida, D, Maeda, T, Ieiri, S, Tanoue, K, Tanaka, M & Hashizume, M 2009, 'The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures', International Journal of Computer Assisted Radiology and Surgery, vol. 4, no. 2, pp. 125-132. https://doi.org/10.1007/s11548-009-0282-5
Ohuchida, Kenoki ; Kenmotsu, Hajime ; Yamamoto, Atsuyuki ; Sawada, Kazuya ; Hayami, Takehito ; Morooka, Kenichi ; Hoshino, Hiroshi ; Uemura, Munenori ; Konishi, Kozo ; Yoshida, Daisuke ; Maeda, Takashi ; Ieiri, Satoshi ; Tanoue, Kazuo ; Tanaka, Masao ; Hashizume, Makoto. / The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures. In: International Journal of Computer Assisted Radiology and Surgery. 2009 ; Vol. 4, No. 2. pp. 125-132.
@article{7385335c0d7646ccbcf9f5553e2418a6,
title = "The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures",
abstract = "Background: Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped display (3DD) system, CyberDome. Study design: In the present study, a total of 23 students volunteered. We evaluated the effects of the 3DD system on depth perception and laparoscopic procedures in comparison with the 2D, a conventional 3D (3DP) or the 2D high definition (HD) systems using seven tasks. Results: The 3DD system significantly improved depth perception and laparoscopic performance compared with the 2D system in six new tasks. We further found that the 3DD system shortened the execution time and reduced the number of errors during suturing and knot tying. The 3DD system also provided more depth perception than the 3DP and 2D HD systems. Conclusions: The novel 3DD system is a promising tool for providing depth perception with high resolution to laparoscopic surgeons.",
author = "Kenoki Ohuchida and Hajime Kenmotsu and Atsuyuki Yamamoto and Kazuya Sawada and Takehito Hayami and Kenichi Morooka and Hiroshi Hoshino and Munenori Uemura and Kozo Konishi and Daisuke Yoshida and Takashi Maeda and Satoshi Ieiri and Kazuo Tanoue and Masao Tanaka and Makoto Hashizume",
year = "2009",
month = "3",
doi = "10.1007/s11548-009-0282-5",
language = "English",
volume = "4",
pages = "125--132",
journal = "Computer-Assisted Radiology and Surgery",
issn = "1861-6410",
publisher = "Springer Verlag",
number = "2",

}

TY - JOUR

T1 - The effect of CyberDome, a novel 3-dimensional dome-shaped display system, on laparoscopic procedures

AU - Ohuchida, Kenoki

AU - Kenmotsu, Hajime

AU - Yamamoto, Atsuyuki

AU - Sawada, Kazuya

AU - Hayami, Takehito

AU - Morooka, Kenichi

AU - Hoshino, Hiroshi

AU - Uemura, Munenori

AU - Konishi, Kozo

AU - Yoshida, Daisuke

AU - Maeda, Takashi

AU - Ieiri, Satoshi

AU - Tanoue, Kazuo

AU - Tanaka, Masao

AU - Hashizume, Makoto

PY - 2009/3

Y1 - 2009/3

N2 - Background: Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped display (3DD) system, CyberDome. Study design: In the present study, a total of 23 students volunteered. We evaluated the effects of the 3DD system on depth perception and laparoscopic procedures in comparison with the 2D, a conventional 3D (3DP) or the 2D high definition (HD) systems using seven tasks. Results: The 3DD system significantly improved depth perception and laparoscopic performance compared with the 2D system in six new tasks. We further found that the 3DD system shortened the execution time and reduced the number of errors during suturing and knot tying. The 3DD system also provided more depth perception than the 3DP and 2D HD systems. Conclusions: The novel 3DD system is a promising tool for providing depth perception with high resolution to laparoscopic surgeons.

AB - Background: Laparoscopic surgeons require extended experience of cases to overcome the lack of depth perception on a two-dimensional (2D) display. Although a three-dimensional (3D) display was reported to be useful over two decades ago, 3D systems have not been widely used. Recently, we developed a novel 3D dome-shaped display (3DD) system, CyberDome. Study design: In the present study, a total of 23 students volunteered. We evaluated the effects of the 3DD system on depth perception and laparoscopic procedures in comparison with the 2D, a conventional 3D (3DP) or the 2D high definition (HD) systems using seven tasks. Results: The 3DD system significantly improved depth perception and laparoscopic performance compared with the 2D system in six new tasks. We further found that the 3DD system shortened the execution time and reduced the number of errors during suturing and knot tying. The 3DD system also provided more depth perception than the 3DP and 2D HD systems. Conclusions: The novel 3DD system is a promising tool for providing depth perception with high resolution to laparoscopic surgeons.

UR - http://www.scopus.com/inward/record.url?scp=67349186331&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67349186331&partnerID=8YFLogxK

U2 - 10.1007/s11548-009-0282-5

DO - 10.1007/s11548-009-0282-5

M3 - Article

C2 - 20033610

AN - SCOPUS:67349186331

VL - 4

SP - 125

EP - 132

JO - Computer-Assisted Radiology and Surgery

JF - Computer-Assisted Radiology and Surgery

SN - 1861-6410

IS - 2

ER -