In this paper, the hygrothermal controll material, the interior finishing material with moisture sorption and desorption characteristics containing PCM (Phase Change Material utilizing latent heat), is developed to provide the function of constant temperature and humidity in buildings. The model experiments and the numerical simulation have examined the influence of the hygrothermal controll materials on the indoor environment. The simulation software "THERB" which has complete HAM features (heat and moisture transfer and airflow) including principles of moisture transfer within walls is used and its accuracy is also verified through the comparison of the calculations and the experiments.

Original languageEnglish
Title of host publicationIBPSA 2009 - International Building Performance Simulation Association 2009
Pages1822-1829
Number of pages8
Publication statusPublished - 2009
Externally publishedYes
Event11th International IBPSA Conference - Building Simulation 2009, BS 2009 - Glasgow, United Kingdom
Duration: Jul 27 2007Jul 30 2007

Other

Other11th International IBPSA Conference - Building Simulation 2009, BS 2009
CountryUnited Kingdom
CityGlasgow
Period7/27/077/30/07

Fingerprint

Sorption
Pulse code modulation
Desorption
Moisture
Interior
Heat
Phase Change Material
Phase change materials
Latent heat
Humidity
Simulation Software
Experiment
Atmospheric humidity
Experiments
Numerical Simulation
Computer simulation
Temperature
Model

All Science Journal Classification (ASJC) codes

  • Computer Science Applications
  • Building and Construction
  • Architecture
  • Modelling and Simulation

Cite this

Ozaki, A., Satou, Y., Lee, M., & Matsuda, C. (2009). The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms. In IBPSA 2009 - International Building Performance Simulation Association 2009 (pp. 1822-1829)

The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms. / Ozaki, Akihito; Satou, Yuki; Lee, Myonghyang; Matsuda, Chisato.

IBPSA 2009 - International Building Performance Simulation Association 2009. 2009. p. 1822-1829.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Ozaki, A, Satou, Y, Lee, M & Matsuda, C 2009, The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms. in IBPSA 2009 - International Building Performance Simulation Association 2009. pp. 1822-1829, 11th International IBPSA Conference - Building Simulation 2009, BS 2009, Glasgow, United Kingdom, 7/27/07.
Ozaki A, Satou Y, Lee M, Matsuda C. The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms. In IBPSA 2009 - International Building Performance Simulation Association 2009. 2009. p. 1822-1829
Ozaki, Akihito ; Satou, Yuki ; Lee, Myonghyang ; Matsuda, Chisato. / The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms. IBPSA 2009 - International Building Performance Simulation Association 2009. 2009. pp. 1822-1829
@inproceedings{e877540fbd4545c3ab51c9c2197f2e71,
title = "The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms",
abstract = "In this paper, the hygrothermal controll material, the interior finishing material with moisture sorption and desorption characteristics containing PCM (Phase Change Material utilizing latent heat), is developed to provide the function of constant temperature and humidity in buildings. The model experiments and the numerical simulation have examined the influence of the hygrothermal controll materials on the indoor environment. The simulation software {"}THERB{"} which has complete HAM features (heat and moisture transfer and airflow) including principles of moisture transfer within walls is used and its accuracy is also verified through the comparison of the calculations and the experiments.",
author = "Akihito Ozaki and Yuki Satou and Myonghyang Lee and Chisato Matsuda",
year = "2009",
language = "English",
pages = "1822--1829",
booktitle = "IBPSA 2009 - International Building Performance Simulation Association 2009",

}

TY - GEN

T1 - The effect of PCM interior finishing material with moisture sorption and desorption characteristics on hygrothermal control of rooms

AU - Ozaki, Akihito

AU - Satou, Yuki

AU - Lee, Myonghyang

AU - Matsuda, Chisato

PY - 2009

Y1 - 2009

N2 - In this paper, the hygrothermal controll material, the interior finishing material with moisture sorption and desorption characteristics containing PCM (Phase Change Material utilizing latent heat), is developed to provide the function of constant temperature and humidity in buildings. The model experiments and the numerical simulation have examined the influence of the hygrothermal controll materials on the indoor environment. The simulation software "THERB" which has complete HAM features (heat and moisture transfer and airflow) including principles of moisture transfer within walls is used and its accuracy is also verified through the comparison of the calculations and the experiments.

AB - In this paper, the hygrothermal controll material, the interior finishing material with moisture sorption and desorption characteristics containing PCM (Phase Change Material utilizing latent heat), is developed to provide the function of constant temperature and humidity in buildings. The model experiments and the numerical simulation have examined the influence of the hygrothermal controll materials on the indoor environment. The simulation software "THERB" which has complete HAM features (heat and moisture transfer and airflow) including principles of moisture transfer within walls is used and its accuracy is also verified through the comparison of the calculations and the experiments.