The effect of potential difference in the solution of electrochemical measurement

Masataka Masuda, Lee Eun Ju, Kenshi Kanada, Makoto Arita

Research output: Contribution to journalArticle

Abstract

The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.

Original languageEnglish
Pages (from-to)275-278
Number of pages4
JournalZairyo to Kankyo/ Corrosion Engineering
Volume53
Issue number5
DOIs
Publication statusPublished - Jan 1 2004

Fingerprint

Electrodes
Finite element method

All Science Journal Classification (ASJC) codes

  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrochemistry
  • Materials Chemistry

Cite this

The effect of potential difference in the solution of electrochemical measurement. / Masuda, Masataka; Ju, Lee Eun; Kanada, Kenshi; Arita, Makoto.

In: Zairyo to Kankyo/ Corrosion Engineering, Vol. 53, No. 5, 01.01.2004, p. 275-278.

Research output: Contribution to journalArticle

Masuda, Masataka ; Ju, Lee Eun ; Kanada, Kenshi ; Arita, Makoto. / The effect of potential difference in the solution of electrochemical measurement. In: Zairyo to Kankyo/ Corrosion Engineering. 2004 ; Vol. 53, No. 5. pp. 275-278.
@article{c2c3d92fd06f432db25f2453b17a1dbc,
title = "The effect of potential difference in the solution of electrochemical measurement",
abstract = "The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.",
author = "Masataka Masuda and Ju, {Lee Eun} and Kenshi Kanada and Makoto Arita",
year = "2004",
month = "1",
day = "1",
doi = "10.3323/jcorr1991.53.275",
language = "English",
volume = "53",
pages = "275--278",
journal = "Corrosion Engineering",
issn = "0917-0480",
publisher = "Japan Society of Corrosion Engineering",
number = "5",

}

TY - JOUR

T1 - The effect of potential difference in the solution of electrochemical measurement

AU - Masuda, Masataka

AU - Ju, Lee Eun

AU - Kanada, Kenshi

AU - Arita, Makoto

PY - 2004/1/1

Y1 - 2004/1/1

N2 - The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.

AB - The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.

UR - http://www.scopus.com/inward/record.url?scp=3142690640&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3142690640&partnerID=8YFLogxK

U2 - 10.3323/jcorr1991.53.275

DO - 10.3323/jcorr1991.53.275

M3 - Article

VL - 53

SP - 275

EP - 278

JO - Corrosion Engineering

JF - Corrosion Engineering

SN - 0917-0480

IS - 5

ER -