The effect of potential difference in the solution of electrochemical measurement

Masataka Masuda, Lee Eun Ju, Kenshi Kanada, Makoto Arita

Research output: Contribution to journalArticle

Abstract

The effect of potential difference in the solution on the electrochemical system was evaluated with the FEM (Finite Element Method) calculation. We made the theoretical analysis for the effect of Luggin capillary on the potential distribution, and the current distribution on the sample electrode. This calculation evaluated the error in the measurement of electrode potential of the electrochemical system. We proposed the optimal position of Luggin capillary for the electrode potential measurements and mentioned the deviation of the current distribution in the electrode surface by the electrode shapes and by the distance between the electrodes.

Original languageEnglish
Pages (from-to)275-278
Number of pages4
JournalZairyo to Kankyo/ Corrosion Engineering
Volume53
Issue number5
DOIs
Publication statusPublished - Jan 1 2004

All Science Journal Classification (ASJC) codes

  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrochemistry
  • Materials Chemistry

Fingerprint Dive into the research topics of 'The effect of potential difference in the solution of electrochemical measurement'. Together they form a unique fingerprint.