The nanometer beam size monitor (Shintake monitor) at ATF2

Masahiro Oroku, Youhei Yamaguchi, Jaqueline Yan, Takashi Yamanaka, Yoshio Kamiya, Taikan Suehara, Sachio Komamiya, Toshiyuki Okugi, Nobuhiro Terunuma, Toshiaki Tauchi, Sakae Araki, Junji Urakawa

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

My presentation focuses on the Shintake (Beamsize) Monitor which can measure nanometer electron beam sizes. The Shintake Monitor is installed in the Accelerator Test Facility 2 (ATF2) at KEK, Japan. ATF2 is a realistic scaled down model of the final focus system for the International Linear Collider. The final focusing scheme named the Local Chromaticity Correction will be tested for the first time in the world. The vertical design beam size at the focal point (virtual interaction point) is 37 nm. Shintake monitor has been designed to measure a beamsize down to 20 nm. It employs the interference pattern made by splitting laser beams and crossing them at the focal point of the electron beam. In their intersecting region, the electromagnetic fields of the two laser beams form a standing wave (interference fringe). The probability of the Compton scattering varies according to the phase of the standing wave where the electrons pass through. Then the total energy of photons from the Compton scattering is measured in a multi-layered ganma ray detector located downstream from the interaction point. This scheme was originally proposed by T. Shintake whose team measured a beamsize of approximately 65 nm with 10 percent resolution at FFTB, SLAC, a former test facility for the ILC. We upgraded this monitor to measure the even smaller beam sizes to be available at ATF2. The laser wavelength has been modified from 1064 nm to 532 nm using a second harmonics generator. The laser optics was newly designed and constructed by implementing a laser wire scheme to measure a larger horizontal beam size, and by enabling different crossing angles of split laser beams to measure a wide (diverse) range of vertical beam sizes. The gamma detector for Shintake monitor has also been newly developed. We evaluated the performance of Shintake monitor with a beam of several microns in size and confirmed its consistency with wire scanner measurements. The expected performance of the Shintake monitor and the current status of the electron beam at ATF, achieved a record in beam size history and near future plan for 37 nm beam size measurement will be mentioned.

Original languageEnglish
Title of host publicationIEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010
Pages1573-1577
Number of pages5
DOIs
Publication statusPublished - Dec 1 2010
Event2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010 - Knoxville, TN, United States
Duration: Oct 30 2010Nov 6 2010

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Other

Other2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010
CountryUnited States
CityKnoxville, TN
Period10/30/1011/6/10

Fingerprint

test facilities
monitors
Lasers
accelerators
Electrons
laser beams
electron beams
standing waves
Electromagnetic Fields
F-22 aircraft
harmonic generators
wire
lasers
Photons
interference
detectors
Japan
History
scattering
scanners

All Science Journal Classification (ASJC) codes

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Cite this

Oroku, M., Yamaguchi, Y., Yan, J., Yamanaka, T., Kamiya, Y., Suehara, T., ... Urakawa, J. (2010). The nanometer beam size monitor (Shintake monitor) at ATF2. In IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010 (pp. 1573-1577). [5874041] (IEEE Nuclear Science Symposium Conference Record). https://doi.org/10.1109/NSSMIC.2010.5874041

The nanometer beam size monitor (Shintake monitor) at ATF2. / Oroku, Masahiro; Yamaguchi, Youhei; Yan, Jaqueline; Yamanaka, Takashi; Kamiya, Yoshio; Suehara, Taikan; Komamiya, Sachio; Okugi, Toshiyuki; Terunuma, Nobuhiro; Tauchi, Toshiaki; Araki, Sakae; Urakawa, Junji.

IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010. 2010. p. 1573-1577 5874041 (IEEE Nuclear Science Symposium Conference Record).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Oroku, M, Yamaguchi, Y, Yan, J, Yamanaka, T, Kamiya, Y, Suehara, T, Komamiya, S, Okugi, T, Terunuma, N, Tauchi, T, Araki, S & Urakawa, J 2010, The nanometer beam size monitor (Shintake monitor) at ATF2. in IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010., 5874041, IEEE Nuclear Science Symposium Conference Record, pp. 1573-1577, 2010 IEEE Nuclear Science Symposium, Medical Imaging Conference, NSS/MIC 2010 and 17th International Workshop on Room-Temperature Semiconductor X-ray and Gamma-ray Detectors, RTSD 2010, Knoxville, TN, United States, 10/30/10. https://doi.org/10.1109/NSSMIC.2010.5874041
Oroku M, Yamaguchi Y, Yan J, Yamanaka T, Kamiya Y, Suehara T et al. The nanometer beam size monitor (Shintake monitor) at ATF2. In IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010. 2010. p. 1573-1577. 5874041. (IEEE Nuclear Science Symposium Conference Record). https://doi.org/10.1109/NSSMIC.2010.5874041
Oroku, Masahiro ; Yamaguchi, Youhei ; Yan, Jaqueline ; Yamanaka, Takashi ; Kamiya, Yoshio ; Suehara, Taikan ; Komamiya, Sachio ; Okugi, Toshiyuki ; Terunuma, Nobuhiro ; Tauchi, Toshiaki ; Araki, Sakae ; Urakawa, Junji. / The nanometer beam size monitor (Shintake monitor) at ATF2. IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010. 2010. pp. 1573-1577 (IEEE Nuclear Science Symposium Conference Record).
@inproceedings{1d4072740d644c81b8b748b13ff36297,
title = "The nanometer beam size monitor (Shintake monitor) at ATF2",
abstract = "My presentation focuses on the Shintake (Beamsize) Monitor which can measure nanometer electron beam sizes. The Shintake Monitor is installed in the Accelerator Test Facility 2 (ATF2) at KEK, Japan. ATF2 is a realistic scaled down model of the final focus system for the International Linear Collider. The final focusing scheme named the Local Chromaticity Correction will be tested for the first time in the world. The vertical design beam size at the focal point (virtual interaction point) is 37 nm. Shintake monitor has been designed to measure a beamsize down to 20 nm. It employs the interference pattern made by splitting laser beams and crossing them at the focal point of the electron beam. In their intersecting region, the electromagnetic fields of the two laser beams form a standing wave (interference fringe). The probability of the Compton scattering varies according to the phase of the standing wave where the electrons pass through. Then the total energy of photons from the Compton scattering is measured in a multi-layered ganma ray detector located downstream from the interaction point. This scheme was originally proposed by T. Shintake whose team measured a beamsize of approximately 65 nm with 10 percent resolution at FFTB, SLAC, a former test facility for the ILC. We upgraded this monitor to measure the even smaller beam sizes to be available at ATF2. The laser wavelength has been modified from 1064 nm to 532 nm using a second harmonics generator. The laser optics was newly designed and constructed by implementing a laser wire scheme to measure a larger horizontal beam size, and by enabling different crossing angles of split laser beams to measure a wide (diverse) range of vertical beam sizes. The gamma detector for Shintake monitor has also been newly developed. We evaluated the performance of Shintake monitor with a beam of several microns in size and confirmed its consistency with wire scanner measurements. The expected performance of the Shintake monitor and the current status of the electron beam at ATF, achieved a record in beam size history and near future plan for 37 nm beam size measurement will be mentioned.",
author = "Masahiro Oroku and Youhei Yamaguchi and Jaqueline Yan and Takashi Yamanaka and Yoshio Kamiya and Taikan Suehara and Sachio Komamiya and Toshiyuki Okugi and Nobuhiro Terunuma and Toshiaki Tauchi and Sakae Araki and Junji Urakawa",
year = "2010",
month = "12",
day = "1",
doi = "10.1109/NSSMIC.2010.5874041",
language = "English",
isbn = "9781424491063",
series = "IEEE Nuclear Science Symposium Conference Record",
pages = "1573--1577",
booktitle = "IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010",

}

TY - GEN

T1 - The nanometer beam size monitor (Shintake monitor) at ATF2

AU - Oroku, Masahiro

AU - Yamaguchi, Youhei

AU - Yan, Jaqueline

AU - Yamanaka, Takashi

AU - Kamiya, Yoshio

AU - Suehara, Taikan

AU - Komamiya, Sachio

AU - Okugi, Toshiyuki

AU - Terunuma, Nobuhiro

AU - Tauchi, Toshiaki

AU - Araki, Sakae

AU - Urakawa, Junji

PY - 2010/12/1

Y1 - 2010/12/1

N2 - My presentation focuses on the Shintake (Beamsize) Monitor which can measure nanometer electron beam sizes. The Shintake Monitor is installed in the Accelerator Test Facility 2 (ATF2) at KEK, Japan. ATF2 is a realistic scaled down model of the final focus system for the International Linear Collider. The final focusing scheme named the Local Chromaticity Correction will be tested for the first time in the world. The vertical design beam size at the focal point (virtual interaction point) is 37 nm. Shintake monitor has been designed to measure a beamsize down to 20 nm. It employs the interference pattern made by splitting laser beams and crossing them at the focal point of the electron beam. In their intersecting region, the electromagnetic fields of the two laser beams form a standing wave (interference fringe). The probability of the Compton scattering varies according to the phase of the standing wave where the electrons pass through. Then the total energy of photons from the Compton scattering is measured in a multi-layered ganma ray detector located downstream from the interaction point. This scheme was originally proposed by T. Shintake whose team measured a beamsize of approximately 65 nm with 10 percent resolution at FFTB, SLAC, a former test facility for the ILC. We upgraded this monitor to measure the even smaller beam sizes to be available at ATF2. The laser wavelength has been modified from 1064 nm to 532 nm using a second harmonics generator. The laser optics was newly designed and constructed by implementing a laser wire scheme to measure a larger horizontal beam size, and by enabling different crossing angles of split laser beams to measure a wide (diverse) range of vertical beam sizes. The gamma detector for Shintake monitor has also been newly developed. We evaluated the performance of Shintake monitor with a beam of several microns in size and confirmed its consistency with wire scanner measurements. The expected performance of the Shintake monitor and the current status of the electron beam at ATF, achieved a record in beam size history and near future plan for 37 nm beam size measurement will be mentioned.

AB - My presentation focuses on the Shintake (Beamsize) Monitor which can measure nanometer electron beam sizes. The Shintake Monitor is installed in the Accelerator Test Facility 2 (ATF2) at KEK, Japan. ATF2 is a realistic scaled down model of the final focus system for the International Linear Collider. The final focusing scheme named the Local Chromaticity Correction will be tested for the first time in the world. The vertical design beam size at the focal point (virtual interaction point) is 37 nm. Shintake monitor has been designed to measure a beamsize down to 20 nm. It employs the interference pattern made by splitting laser beams and crossing them at the focal point of the electron beam. In their intersecting region, the electromagnetic fields of the two laser beams form a standing wave (interference fringe). The probability of the Compton scattering varies according to the phase of the standing wave where the electrons pass through. Then the total energy of photons from the Compton scattering is measured in a multi-layered ganma ray detector located downstream from the interaction point. This scheme was originally proposed by T. Shintake whose team measured a beamsize of approximately 65 nm with 10 percent resolution at FFTB, SLAC, a former test facility for the ILC. We upgraded this monitor to measure the even smaller beam sizes to be available at ATF2. The laser wavelength has been modified from 1064 nm to 532 nm using a second harmonics generator. The laser optics was newly designed and constructed by implementing a laser wire scheme to measure a larger horizontal beam size, and by enabling different crossing angles of split laser beams to measure a wide (diverse) range of vertical beam sizes. The gamma detector for Shintake monitor has also been newly developed. We evaluated the performance of Shintake monitor with a beam of several microns in size and confirmed its consistency with wire scanner measurements. The expected performance of the Shintake monitor and the current status of the electron beam at ATF, achieved a record in beam size history and near future plan for 37 nm beam size measurement will be mentioned.

UR - http://www.scopus.com/inward/record.url?scp=79960326763&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960326763&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2010.5874041

DO - 10.1109/NSSMIC.2010.5874041

M3 - Conference contribution

AN - SCOPUS:79960326763

SN - 9781424491063

T3 - IEEE Nuclear Science Symposium Conference Record

SP - 1573

EP - 1577

BT - IEEE Nuclear Science Symposuim and Medical Imaging Conference, NSS/MIC 2010

ER -