The transparent microstrip gas counter

Hiroyuki Takahashi, Kaoru Fujita, Takeshi Fujiwara, Hisako Niko, Bruno Guerard, Francisco Fraga, Naoko Iyomoto

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Conventional MSGCs are made of metal electrodes that might absorb or reflect optical photons. If the electrodes are made of transparent material like ITO, we could take advantage of optical readout. A gas scintillation proportional counter made of ITO MSGC is fabricated and tested where both optical and charge signals are obtained. We have selected a multi-grid structure that can avoid charge-up problem with normal transparent glass substrate. Test results with Ar and CF4 gas mixture showed a stable gas gain of ∼2800 and ∼110 optical photons for 6 keV X-rays. Position sensing with PSPMT has successfully been demonstrated.

Original languageEnglish
Pages (from-to)123-125
Number of pages3
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume623
Issue number1
DOIs
Publication statusPublished - Nov 1 2010
Externally publishedYes

Fingerprint

ITO (semiconductors)
counters
Photons
position sensing
Proportional counters
Scintillation counters
Electrodes
transparence
electrodes
proportional counters
photons
Gases
gases
Gas mixtures
scintillation counters
gas mixtures
optical communication
readout
grids
X rays

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

The transparent microstrip gas counter. / Takahashi, Hiroyuki; Fujita, Kaoru; Fujiwara, Takeshi; Niko, Hisako; Guerard, Bruno; Fraga, Francisco; Iyomoto, Naoko.

In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 623, No. 1, 01.11.2010, p. 123-125.

Research output: Contribution to journalArticle

Takahashi, Hiroyuki ; Fujita, Kaoru ; Fujiwara, Takeshi ; Niko, Hisako ; Guerard, Bruno ; Fraga, Francisco ; Iyomoto, Naoko. / The transparent microstrip gas counter. In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2010 ; Vol. 623, No. 1. pp. 123-125.
@article{f374f4ed680f4e3797f29fb181e38286,
title = "The transparent microstrip gas counter",
abstract = "Conventional MSGCs are made of metal electrodes that might absorb or reflect optical photons. If the electrodes are made of transparent material like ITO, we could take advantage of optical readout. A gas scintillation proportional counter made of ITO MSGC is fabricated and tested where both optical and charge signals are obtained. We have selected a multi-grid structure that can avoid charge-up problem with normal transparent glass substrate. Test results with Ar and CF4 gas mixture showed a stable gas gain of ∼2800 and ∼110 optical photons for 6 keV X-rays. Position sensing with PSPMT has successfully been demonstrated.",
author = "Hiroyuki Takahashi and Kaoru Fujita and Takeshi Fujiwara and Hisako Niko and Bruno Guerard and Francisco Fraga and Naoko Iyomoto",
year = "2010",
month = "11",
day = "1",
doi = "10.1016/j.nima.2010.02.169",
language = "English",
volume = "623",
pages = "123--125",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - The transparent microstrip gas counter

AU - Takahashi, Hiroyuki

AU - Fujita, Kaoru

AU - Fujiwara, Takeshi

AU - Niko, Hisako

AU - Guerard, Bruno

AU - Fraga, Francisco

AU - Iyomoto, Naoko

PY - 2010/11/1

Y1 - 2010/11/1

N2 - Conventional MSGCs are made of metal electrodes that might absorb or reflect optical photons. If the electrodes are made of transparent material like ITO, we could take advantage of optical readout. A gas scintillation proportional counter made of ITO MSGC is fabricated and tested where both optical and charge signals are obtained. We have selected a multi-grid structure that can avoid charge-up problem with normal transparent glass substrate. Test results with Ar and CF4 gas mixture showed a stable gas gain of ∼2800 and ∼110 optical photons for 6 keV X-rays. Position sensing with PSPMT has successfully been demonstrated.

AB - Conventional MSGCs are made of metal electrodes that might absorb or reflect optical photons. If the electrodes are made of transparent material like ITO, we could take advantage of optical readout. A gas scintillation proportional counter made of ITO MSGC is fabricated and tested where both optical and charge signals are obtained. We have selected a multi-grid structure that can avoid charge-up problem with normal transparent glass substrate. Test results with Ar and CF4 gas mixture showed a stable gas gain of ∼2800 and ∼110 optical photons for 6 keV X-rays. Position sensing with PSPMT has successfully been demonstrated.

UR - http://www.scopus.com/inward/record.url?scp=77957833255&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77957833255&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2010.02.169

DO - 10.1016/j.nima.2010.02.169

M3 - Article

AN - SCOPUS:77957833255

VL - 623

SP - 123

EP - 125

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 1

ER -