TY - JOUR
T1 - The utility of visceral fat level by bioelectrical impedance analysis in the screening of metabolic syndrome- The results of the Kyushu and Okinawa population study (KOPS)
AU - Unno, Mami
AU - Furusyo, Norihiro
AU - Mukae, Haru
AU - Koga, Tsunehisa
AU - Eiraku, Kunimitsu
AU - Hayashi, Jun
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2012
Y1 - 2012
N2 - Aim: A simple, non-invasive medical device, using bioelectrical impedance analysis (BIA) for the evaluation of visceral fat level (VFL) was developed recently. The aim of this study was to investigate the utility of VFL by BIA in the screening of metabolic syndrome (MetS). Methods: VFL was measured by the BIA device in 1,451 Japanese residents (546 men and 905 women, age range 30-69 years). Results: VFL had significant positive correlations with waist circumference (WC) and body mass index (r = 0.772 and 0.849, all <0.0001). The overall MetS prevalence using Japanese Diagnosis Criteria was 19.8%: men 36.3% and women 9.8%. The mean VFL of the participants with MetS was significantly higher than those without MetS (men; 12.1 and 9.4, women; 13.3 and 8.7) (both P<0.001). VFL significantly correlated with blood pressure, lipid profiles, fasting plasma glucose, and hemoglobin A1c (all P<0.001). Receiver operating characteristic curve analysis for a diagnosis of two or more MetS risk factors excluding WC resulted in the same cutoff values for the VFL (10.0) of men and women. Conclusions: The VFL by BIA is useful for the detection of MetS because it is correlated with all metabolic parameters and shows the same normal limit in both sexes.
AB - Aim: A simple, non-invasive medical device, using bioelectrical impedance analysis (BIA) for the evaluation of visceral fat level (VFL) was developed recently. The aim of this study was to investigate the utility of VFL by BIA in the screening of metabolic syndrome (MetS). Methods: VFL was measured by the BIA device in 1,451 Japanese residents (546 men and 905 women, age range 30-69 years). Results: VFL had significant positive correlations with waist circumference (WC) and body mass index (r = 0.772 and 0.849, all <0.0001). The overall MetS prevalence using Japanese Diagnosis Criteria was 19.8%: men 36.3% and women 9.8%. The mean VFL of the participants with MetS was significantly higher than those without MetS (men; 12.1 and 9.4, women; 13.3 and 8.7) (both P<0.001). VFL significantly correlated with blood pressure, lipid profiles, fasting plasma glucose, and hemoglobin A1c (all P<0.001). Receiver operating characteristic curve analysis for a diagnosis of two or more MetS risk factors excluding WC resulted in the same cutoff values for the VFL (10.0) of men and women. Conclusions: The VFL by BIA is useful for the detection of MetS because it is correlated with all metabolic parameters and shows the same normal limit in both sexes.
UR - http://www.scopus.com/inward/record.url?scp=84861614265&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84861614265&partnerID=8YFLogxK
U2 - 10.5551/jat.11528
DO - 10.5551/jat.11528
M3 - Article
C2 - 22659530
AN - SCOPUS:84861614265
SN - 1340-3478
VL - 19
SP - 462
EP - 470
JO - Journal of Atherosclerosis and Thrombosis
JF - Journal of Atherosclerosis and Thrombosis
IS - 5
ER -