Thermal conductivity measurement of hydrogen at high pressure and high temperature

Koichi Kimura, Shogo Moroe, Peter Woodfield, Jun Fukai, Kan'ei Shinzato, Masamichi Kohno, Motoo Fujii, Yasuyuki Takata

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The thermal conductivities and thermal diffusivities of hydrogen were measured with a transient short hot wire method for temperature range up to 300 °C and pressure range up to100MPa. The measured thermal conductivities showed good reproducibility and agreed with the existing values within a deviation of ±2%.

Original languageEnglish
Title of host publicationASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011
Publication statusPublished - Dec 1 2011
EventASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011 - Honolulu, HI, United States
Duration: Mar 13 2011Mar 17 2011

Other

OtherASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011
CountryUnited States
CityHonolulu, HI
Period3/13/113/17/11

Fingerprint

Thermal conductivity
Hydrogen
Thermal diffusivity
Wire
Temperature

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology

Cite this

Kimura, K., Moroe, S., Woodfield, P., Fukai, J., Shinzato, K., Kohno, M., ... Takata, Y. (2011). Thermal conductivity measurement of hydrogen at high pressure and high temperature. In ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011

Thermal conductivity measurement of hydrogen at high pressure and high temperature. / Kimura, Koichi; Moroe, Shogo; Woodfield, Peter; Fukai, Jun; Shinzato, Kan'ei; Kohno, Masamichi; Fujii, Motoo; Takata, Yasuyuki.

ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011. 2011.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kimura, K, Moroe, S, Woodfield, P, Fukai, J, Shinzato, K, Kohno, M, Fujii, M & Takata, Y 2011, Thermal conductivity measurement of hydrogen at high pressure and high temperature. in ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011. ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011, Honolulu, HI, United States, 3/13/11.
Kimura K, Moroe S, Woodfield P, Fukai J, Shinzato K, Kohno M et al. Thermal conductivity measurement of hydrogen at high pressure and high temperature. In ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011. 2011
Kimura, Koichi ; Moroe, Shogo ; Woodfield, Peter ; Fukai, Jun ; Shinzato, Kan'ei ; Kohno, Masamichi ; Fujii, Motoo ; Takata, Yasuyuki. / Thermal conductivity measurement of hydrogen at high pressure and high temperature. ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011. 2011.
@inproceedings{a2757df8a86c4edd85531ce32513db01,
title = "Thermal conductivity measurement of hydrogen at high pressure and high temperature",
abstract = "The thermal conductivities and thermal diffusivities of hydrogen were measured with a transient short hot wire method for temperature range up to 300 °C and pressure range up to100MPa. The measured thermal conductivities showed good reproducibility and agreed with the existing values within a deviation of ±2{\%}.",
author = "Koichi Kimura and Shogo Moroe and Peter Woodfield and Jun Fukai and Kan'ei Shinzato and Masamichi Kohno and Motoo Fujii and Yasuyuki Takata",
year = "2011",
month = "12",
day = "1",
language = "English",
isbn = "9780791838921",
booktitle = "ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011",

}

TY - GEN

T1 - Thermal conductivity measurement of hydrogen at high pressure and high temperature

AU - Kimura, Koichi

AU - Moroe, Shogo

AU - Woodfield, Peter

AU - Fukai, Jun

AU - Shinzato, Kan'ei

AU - Kohno, Masamichi

AU - Fujii, Motoo

AU - Takata, Yasuyuki

PY - 2011/12/1

Y1 - 2011/12/1

N2 - The thermal conductivities and thermal diffusivities of hydrogen were measured with a transient short hot wire method for temperature range up to 300 °C and pressure range up to100MPa. The measured thermal conductivities showed good reproducibility and agreed with the existing values within a deviation of ±2%.

AB - The thermal conductivities and thermal diffusivities of hydrogen were measured with a transient short hot wire method for temperature range up to 300 °C and pressure range up to100MPa. The measured thermal conductivities showed good reproducibility and agreed with the existing values within a deviation of ±2%.

UR - http://www.scopus.com/inward/record.url?scp=84860895933&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860895933&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84860895933

SN - 9780791838921

BT - ASME/JSME 2011 8th Thermal Engineering Joint Conference, AJTEC 2011

ER -