Three-dimensional visualization of dislocations in a ferromagnetic material by magnetic-field-free electron tomography

Kana L. Hasezaki, Hikaru Saito, Takumi Sannomiya, Hiroya Miyazaki, Takashi Gondo, Shinsuke Miyazaki, Satoshi Hata

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

In conventional transmission electron microscopy, specimens to be observed are placed in between the objective lens pole piece and therefore exposed to a strong magnetic field about 2 T. For a ferromagnetic specimen, magnetization of the specimen causes isotropic and anisotropic defocusing, deflection of the electron beam as well as deformation of the specimen, which all become more severe when the specimen tilted. Therefore electron tomography on a ferromagnetic crystalline specimen is highly challenging because tilt-series data sets must be acquired without changing the excitation condition of a specific diffraction spot. In this study, a scanning transmission electron microscopy (STEM) tomography method without magnetizing a ferromagnetic specimen has been developed for three-dimensional (3D) visualization of dislocations in α-Fe, which is a typical ferromagnetic material. Magnetic-field-free environment down to 0.38 ± 0.07 mT at the specimen position is realized by demagnetizing the objective lens pole piece of a commercial STEM instrument. By using a spherical aberration corrector with the magnetic-field-free environment, an “aberration corrected Low-Mag STEM mode” with no objective lens field reaches a convergence semi angle ∼1 mrad and a spatial resolution ∼5 nm, and shows an adequate performance of imaging dislocations under a two-beam excitation condition for a low-index diffracted beam. The illumination condition for the aberration corrected Low-Mag STEM mode gives no overlap between the direct beam disk (spot) and neighboring diffraction disks. An electron channeling contrast imaging technique, in which an annular detector was located at a doughnut area between the direct beam and the neighboring diffracted beams, was effectively employed with the aberration corrected Low-Mag STEM mode to keep image intensity high enough even at large specimen-tilt angles. The resultant tomographic observation visualized 3D dislocation arrangements and active slip planes in a deformed α-Fe specimen.

Original languageEnglish
Pages (from-to)249-257
Number of pages9
JournalUltramicroscopy
Volume182
DOIs
Publication statusPublished - Nov 1 2017

Fingerprint

Ferromagnetic materials
ferromagnetic materials
free electrons
Tomography
Visualization
tomography
Magnetic fields
Transmission electron microscopy
Aberrations
Electrons
Scanning electron microscopy
magnetic fields
Lenses
transmission electron microscopy
aberration
scanning electron microscopy
Poles
Diffraction
lenses
Imaging techniques

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Instrumentation

Cite this

Three-dimensional visualization of dislocations in a ferromagnetic material by magnetic-field-free electron tomography. / Hasezaki, Kana L.; Saito, Hikaru; Sannomiya, Takumi; Miyazaki, Hiroya; Gondo, Takashi; Miyazaki, Shinsuke; Hata, Satoshi.

In: Ultramicroscopy, Vol. 182, 01.11.2017, p. 249-257.

Research output: Contribution to journalArticle

Hasezaki, Kana L. ; Saito, Hikaru ; Sannomiya, Takumi ; Miyazaki, Hiroya ; Gondo, Takashi ; Miyazaki, Shinsuke ; Hata, Satoshi. / Three-dimensional visualization of dislocations in a ferromagnetic material by magnetic-field-free electron tomography. In: Ultramicroscopy. 2017 ; Vol. 182. pp. 249-257.
@article{08150b94c14e495296e3125f5b57c1af,
title = "Three-dimensional visualization of dislocations in a ferromagnetic material by magnetic-field-free electron tomography",
abstract = "In conventional transmission electron microscopy, specimens to be observed are placed in between the objective lens pole piece and therefore exposed to a strong magnetic field about 2 T. For a ferromagnetic specimen, magnetization of the specimen causes isotropic and anisotropic defocusing, deflection of the electron beam as well as deformation of the specimen, which all become more severe when the specimen tilted. Therefore electron tomography on a ferromagnetic crystalline specimen is highly challenging because tilt-series data sets must be acquired without changing the excitation condition of a specific diffraction spot. In this study, a scanning transmission electron microscopy (STEM) tomography method without magnetizing a ferromagnetic specimen has been developed for three-dimensional (3D) visualization of dislocations in α-Fe, which is a typical ferromagnetic material. Magnetic-field-free environment down to 0.38 ± 0.07 mT at the specimen position is realized by demagnetizing the objective lens pole piece of a commercial STEM instrument. By using a spherical aberration corrector with the magnetic-field-free environment, an “aberration corrected Low-Mag STEM mode” with no objective lens field reaches a convergence semi angle ∼1 mrad and a spatial resolution ∼5 nm, and shows an adequate performance of imaging dislocations under a two-beam excitation condition for a low-index diffracted beam. The illumination condition for the aberration corrected Low-Mag STEM mode gives no overlap between the direct beam disk (spot) and neighboring diffraction disks. An electron channeling contrast imaging technique, in which an annular detector was located at a doughnut area between the direct beam and the neighboring diffracted beams, was effectively employed with the aberration corrected Low-Mag STEM mode to keep image intensity high enough even at large specimen-tilt angles. The resultant tomographic observation visualized 3D dislocation arrangements and active slip planes in a deformed α-Fe specimen.",
author = "Hasezaki, {Kana L.} and Hikaru Saito and Takumi Sannomiya and Hiroya Miyazaki and Takashi Gondo and Shinsuke Miyazaki and Satoshi Hata",
year = "2017",
month = "11",
day = "1",
doi = "10.1016/j.ultramic.2017.07.016",
language = "English",
volume = "182",
pages = "249--257",
journal = "Ultramicroscopy",
issn = "0304-3991",
publisher = "Elsevier",

}

TY - JOUR

T1 - Three-dimensional visualization of dislocations in a ferromagnetic material by magnetic-field-free electron tomography

AU - Hasezaki, Kana L.

AU - Saito, Hikaru

AU - Sannomiya, Takumi

AU - Miyazaki, Hiroya

AU - Gondo, Takashi

AU - Miyazaki, Shinsuke

AU - Hata, Satoshi

PY - 2017/11/1

Y1 - 2017/11/1

N2 - In conventional transmission electron microscopy, specimens to be observed are placed in between the objective lens pole piece and therefore exposed to a strong magnetic field about 2 T. For a ferromagnetic specimen, magnetization of the specimen causes isotropic and anisotropic defocusing, deflection of the electron beam as well as deformation of the specimen, which all become more severe when the specimen tilted. Therefore electron tomography on a ferromagnetic crystalline specimen is highly challenging because tilt-series data sets must be acquired without changing the excitation condition of a specific diffraction spot. In this study, a scanning transmission electron microscopy (STEM) tomography method without magnetizing a ferromagnetic specimen has been developed for three-dimensional (3D) visualization of dislocations in α-Fe, which is a typical ferromagnetic material. Magnetic-field-free environment down to 0.38 ± 0.07 mT at the specimen position is realized by demagnetizing the objective lens pole piece of a commercial STEM instrument. By using a spherical aberration corrector with the magnetic-field-free environment, an “aberration corrected Low-Mag STEM mode” with no objective lens field reaches a convergence semi angle ∼1 mrad and a spatial resolution ∼5 nm, and shows an adequate performance of imaging dislocations under a two-beam excitation condition for a low-index diffracted beam. The illumination condition for the aberration corrected Low-Mag STEM mode gives no overlap between the direct beam disk (spot) and neighboring diffraction disks. An electron channeling contrast imaging technique, in which an annular detector was located at a doughnut area between the direct beam and the neighboring diffracted beams, was effectively employed with the aberration corrected Low-Mag STEM mode to keep image intensity high enough even at large specimen-tilt angles. The resultant tomographic observation visualized 3D dislocation arrangements and active slip planes in a deformed α-Fe specimen.

AB - In conventional transmission electron microscopy, specimens to be observed are placed in between the objective lens pole piece and therefore exposed to a strong magnetic field about 2 T. For a ferromagnetic specimen, magnetization of the specimen causes isotropic and anisotropic defocusing, deflection of the electron beam as well as deformation of the specimen, which all become more severe when the specimen tilted. Therefore electron tomography on a ferromagnetic crystalline specimen is highly challenging because tilt-series data sets must be acquired without changing the excitation condition of a specific diffraction spot. In this study, a scanning transmission electron microscopy (STEM) tomography method without magnetizing a ferromagnetic specimen has been developed for three-dimensional (3D) visualization of dislocations in α-Fe, which is a typical ferromagnetic material. Magnetic-field-free environment down to 0.38 ± 0.07 mT at the specimen position is realized by demagnetizing the objective lens pole piece of a commercial STEM instrument. By using a spherical aberration corrector with the magnetic-field-free environment, an “aberration corrected Low-Mag STEM mode” with no objective lens field reaches a convergence semi angle ∼1 mrad and a spatial resolution ∼5 nm, and shows an adequate performance of imaging dislocations under a two-beam excitation condition for a low-index diffracted beam. The illumination condition for the aberration corrected Low-Mag STEM mode gives no overlap between the direct beam disk (spot) and neighboring diffraction disks. An electron channeling contrast imaging technique, in which an annular detector was located at a doughnut area between the direct beam and the neighboring diffracted beams, was effectively employed with the aberration corrected Low-Mag STEM mode to keep image intensity high enough even at large specimen-tilt angles. The resultant tomographic observation visualized 3D dislocation arrangements and active slip planes in a deformed α-Fe specimen.

UR - http://www.scopus.com/inward/record.url?scp=85026677687&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85026677687&partnerID=8YFLogxK

U2 - 10.1016/j.ultramic.2017.07.016

DO - 10.1016/j.ultramic.2017.07.016

M3 - Article

AN - SCOPUS:85026677687

VL - 182

SP - 249

EP - 257

JO - Ultramicroscopy

JF - Ultramicroscopy

SN - 0304-3991

ER -