TY - JOUR
T1 - Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty
AU - Okamoto, Shigetoshi
AU - Mizu-uchi, Hideki
AU - Okazaki, Ken
AU - Hamai, Satoshi
AU - Tashiro, Yasutaka
AU - Nakahara, Hiroyuki
AU - Iwamoto, Yukihide
N1 - Publisher Copyright:
© 2014, European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA).
PY - 2016/1/1
Y1 - 2016/1/1
N2 - Purpose: The first purpose of this study was to compare the reproducibility of two-dimensional (2D) and three-dimensional (3D) measurements for preoperative planning of the femoral side in total knee arthroplasty (TKA). The second purpose was to evaluate the factors affecting the differences between the 2D and 3D measurements. Methods: Two-dimensional and 3D measurements for preoperative planning of the femoral side in TKA were evaluated in 75 varus knees with osteoarthritis. The femoral valgus angle, defined as the angle between the mechanical and anatomical axes of the femur, and the clinical rotation angle and surgical rotation angle, defined by the angles between the posterior condylar line and the clinical or surgical transepicondylar axes, respectively, were analysed using 2D (radiographs and axial CT slices) and 3D (3D bone models reconstructed from CT images) measurements. Results: For all variables, 3D measurements were more reliable and reproducible than 2D measurements. The medians and ranges of the clinical rotation angle and surgical rotation angle were 6.6° (−1.7° to 12.1°) and 2.3° (−2.5° to 8.6°) in 2D, and 7.1° (2.7° to 11.4°) and 3.0° (−2.0° to 7.5°) in 3D. Varus/valgus alteration of the CT scanning direction relative to the mechanical axis affected the difference in clinical rotation angles between 2D and 3D measurements. Conclusion: Significantly, smaller values of the clinical rotation angle and surgical rotation angle were obtained by 2D compared to 3D measurements, which could result in internal rotation of the femoral component even if the surgeon performs the bone cutting precisely. Regarding clinical relevance, first, this study confirmed the reliability of 3D measurements. Second, it underscored the risk of internal rotation of the femoral component when using 2D measurement, even with precise bone cutting technique. These results will help surgeons avoid malpositioning of the femoral component if 2D measurements are used for preoperative planning in TKA. Level of evidence: Prospective comparative study, Level Ш.
AB - Purpose: The first purpose of this study was to compare the reproducibility of two-dimensional (2D) and three-dimensional (3D) measurements for preoperative planning of the femoral side in total knee arthroplasty (TKA). The second purpose was to evaluate the factors affecting the differences between the 2D and 3D measurements. Methods: Two-dimensional and 3D measurements for preoperative planning of the femoral side in TKA were evaluated in 75 varus knees with osteoarthritis. The femoral valgus angle, defined as the angle between the mechanical and anatomical axes of the femur, and the clinical rotation angle and surgical rotation angle, defined by the angles between the posterior condylar line and the clinical or surgical transepicondylar axes, respectively, were analysed using 2D (radiographs and axial CT slices) and 3D (3D bone models reconstructed from CT images) measurements. Results: For all variables, 3D measurements were more reliable and reproducible than 2D measurements. The medians and ranges of the clinical rotation angle and surgical rotation angle were 6.6° (−1.7° to 12.1°) and 2.3° (−2.5° to 8.6°) in 2D, and 7.1° (2.7° to 11.4°) and 3.0° (−2.0° to 7.5°) in 3D. Varus/valgus alteration of the CT scanning direction relative to the mechanical axis affected the difference in clinical rotation angles between 2D and 3D measurements. Conclusion: Significantly, smaller values of the clinical rotation angle and surgical rotation angle were obtained by 2D compared to 3D measurements, which could result in internal rotation of the femoral component even if the surgeon performs the bone cutting precisely. Regarding clinical relevance, first, this study confirmed the reliability of 3D measurements. Second, it underscored the risk of internal rotation of the femoral component when using 2D measurement, even with precise bone cutting technique. These results will help surgeons avoid malpositioning of the femoral component if 2D measurements are used for preoperative planning in TKA. Level of evidence: Prospective comparative study, Level Ш.
UR - http://www.scopus.com/inward/record.url?scp=84958152403&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84958152403&partnerID=8YFLogxK
U2 - 10.1007/s00167-014-3370-1
DO - 10.1007/s00167-014-3370-1
M3 - Article
C2 - 25297705
AN - SCOPUS:84958152403
SN - 0942-2056
VL - 24
SP - 229
EP - 235
JO - Knee Surgery, Sports Traumatology, Arthroscopy
JF - Knee Surgery, Sports Traumatology, Arthroscopy
IS - 1
ER -