Two-dimensional transmission counter with a backgammon-drift read-out technique

Sutomo Budihardjo, Takeji Sakae, Hajime Fujimura, Akihiro Nohtomi, Yusuke Uozumi, Masaru Matoba

Research output: Contribution to conferencePaper

3 Citations (Scopus)

Abstract

A new type of two-dimensional position sensitive gas counter for transmission counter with a backgammon-shaped flat electrode has been developed. The two dimensional position read-out can be achieved with the combination of a backgammon-shaped flat electrode read-out as horizontal position and the drift time measurement read-out as vertical position. The gas counter is designed as a transmission trajectory counter that can be used to determine angle of incident charged particles in charged particle detecting system. To check the characteristics of this gas counter, test experiments are performed with a coincidence plastic scintillation counter and β-ray source of 90Sr.

Original languageEnglish
Pages153-156
Number of pages4
Publication statusPublished - Dec 1 1995
EventProceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) - San Francisco, CA, USA
Duration: Oct 21 1995Oct 28 1995

Other

OtherProceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3)
CitySan Francisco, CA, USA
Period10/21/9510/28/95

Fingerprint

Charged particles
Gases
Scintillation counters
Electrodes
Time measurement
Trajectories
Plastics
Experiments

All Science Journal Classification (ASJC) codes

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Budihardjo, S., Sakae, T., Fujimura, H., Nohtomi, A., Uozumi, Y., & Matoba, M. (1995). Two-dimensional transmission counter with a backgammon-drift read-out technique. 153-156. Paper presented at Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .

Two-dimensional transmission counter with a backgammon-drift read-out technique. / Budihardjo, Sutomo; Sakae, Takeji; Fujimura, Hajime; Nohtomi, Akihiro; Uozumi, Yusuke; Matoba, Masaru.

1995. 153-156 Paper presented at Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .

Research output: Contribution to conferencePaper

Budihardjo, S, Sakae, T, Fujimura, H, Nohtomi, A, Uozumi, Y & Matoba, M 1995, 'Two-dimensional transmission counter with a backgammon-drift read-out technique', Paper presented at Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, 10/21/95 - 10/28/95 pp. 153-156.
Budihardjo S, Sakae T, Fujimura H, Nohtomi A, Uozumi Y, Matoba M. Two-dimensional transmission counter with a backgammon-drift read-out technique. 1995. Paper presented at Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .
Budihardjo, Sutomo ; Sakae, Takeji ; Fujimura, Hajime ; Nohtomi, Akihiro ; Uozumi, Yusuke ; Matoba, Masaru. / Two-dimensional transmission counter with a backgammon-drift read-out technique. Paper presented at Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3), San Francisco, CA, USA, .4 p.
@conference{510a444161f1412e931175ae4ad29b87,
title = "Two-dimensional transmission counter with a backgammon-drift read-out technique",
abstract = "A new type of two-dimensional position sensitive gas counter for transmission counter with a backgammon-shaped flat electrode has been developed. The two dimensional position read-out can be achieved with the combination of a backgammon-shaped flat electrode read-out as horizontal position and the drift time measurement read-out as vertical position. The gas counter is designed as a transmission trajectory counter that can be used to determine angle of incident charged particles in charged particle detecting system. To check the characteristics of this gas counter, test experiments are performed with a coincidence plastic scintillation counter and β-ray source of 90Sr.",
author = "Sutomo Budihardjo and Takeji Sakae and Hajime Fujimura and Akihiro Nohtomi and Yusuke Uozumi and Masaru Matoba",
year = "1995",
month = "12",
day = "1",
language = "English",
pages = "153--156",
note = "Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) ; Conference date: 21-10-1995 Through 28-10-1995",

}

TY - CONF

T1 - Two-dimensional transmission counter with a backgammon-drift read-out technique

AU - Budihardjo, Sutomo

AU - Sakae, Takeji

AU - Fujimura, Hajime

AU - Nohtomi, Akihiro

AU - Uozumi, Yusuke

AU - Matoba, Masaru

PY - 1995/12/1

Y1 - 1995/12/1

N2 - A new type of two-dimensional position sensitive gas counter for transmission counter with a backgammon-shaped flat electrode has been developed. The two dimensional position read-out can be achieved with the combination of a backgammon-shaped flat electrode read-out as horizontal position and the drift time measurement read-out as vertical position. The gas counter is designed as a transmission trajectory counter that can be used to determine angle of incident charged particles in charged particle detecting system. To check the characteristics of this gas counter, test experiments are performed with a coincidence plastic scintillation counter and β-ray source of 90Sr.

AB - A new type of two-dimensional position sensitive gas counter for transmission counter with a backgammon-shaped flat electrode has been developed. The two dimensional position read-out can be achieved with the combination of a backgammon-shaped flat electrode read-out as horizontal position and the drift time measurement read-out as vertical position. The gas counter is designed as a transmission trajectory counter that can be used to determine angle of incident charged particles in charged particle detecting system. To check the characteristics of this gas counter, test experiments are performed with a coincidence plastic scintillation counter and β-ray source of 90Sr.

UR - http://www.scopus.com/inward/record.url?scp=0029457832&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029457832&partnerID=8YFLogxK

M3 - Paper

AN - SCOPUS:0029457832

SP - 153

EP - 156

ER -