Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment

Hiroki Watanabe, Nozomu Yamazaki, Yosuke Isobe, Xiaowei Lu, Yo Kobayashi, Tomoyuki Miyashita, Takeshi Ohdaira, Makoto Hashizume, Masakatsu G. Fujie

Research output: Chapter in Book/Report/Conference proceedingConference contribution

6 Citations (Scopus)

Abstract

Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

Original languageEnglish
Title of host publication2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012
Pages5712-5717
Number of pages6
DOIs
Publication statusPublished - Dec 14 2012
Event34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012 - San Diego, CA, United States
Duration: Aug 28 2012Sep 1 2012

Publication series

NameProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN (Print)1557-170X

Other

Other34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012
CountryUnited States
CitySan Diego, CA
Period8/28/129/1/12

Fingerprint

Thermal Conductivity
Ablation
Liver
Thermal conductivity
Temperature
Coagulation
Experiments
Robotics
Tumors
Temperature distribution
Simulators
In Vitro Techniques
Neoplasms
Imaging techniques
Computer simulation

All Science Journal Classification (ASJC) codes

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

Watanabe, H., Yamazaki, N., Isobe, Y., Lu, X., Kobayashi, Y., Miyashita, T., ... Fujie, M. G. (2012). Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment. In 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012 (pp. 5712-5717). [6347292] (Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS). https://doi.org/10.1109/EMBC.2012.6347292

Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment. / Watanabe, Hiroki; Yamazaki, Nozomu; Isobe, Yosuke; Lu, Xiaowei; Kobayashi, Yo; Miyashita, Tomoyuki; Ohdaira, Takeshi; Hashizume, Makoto; Fujie, Masakatsu G.

2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012. 2012. p. 5712-5717 6347292 (Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Watanabe, H, Yamazaki, N, Isobe, Y, Lu, X, Kobayashi, Y, Miyashita, T, Ohdaira, T, Hashizume, M & Fujie, MG 2012, Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment. in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012., 6347292, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, pp. 5712-5717, 34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012, San Diego, CA, United States, 8/28/12. https://doi.org/10.1109/EMBC.2012.6347292
Watanabe H, Yamazaki N, Isobe Y, Lu X, Kobayashi Y, Miyashita T et al. Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment. In 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012. 2012. p. 5712-5717. 6347292. (Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS). https://doi.org/10.1109/EMBC.2012.6347292
Watanabe, Hiroki ; Yamazaki, Nozomu ; Isobe, Yosuke ; Lu, Xiaowei ; Kobayashi, Yo ; Miyashita, Tomoyuki ; Ohdaira, Takeshi ; Hashizume, Makoto ; Fujie, Masakatsu G. / Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment. 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012. 2012. pp. 5712-5717 (Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS).
@inproceedings{6389561fc00d4dd9af41fcc44d376e69,
title = "Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment",
abstract = "Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.",
author = "Hiroki Watanabe and Nozomu Yamazaki and Yosuke Isobe and Xiaowei Lu and Yo Kobayashi and Tomoyuki Miyashita and Takeshi Ohdaira and Makoto Hashizume and Fujie, {Masakatsu G.}",
year = "2012",
month = "12",
day = "14",
doi = "10.1109/EMBC.2012.6347292",
language = "English",
isbn = "9781424441198",
series = "Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS",
pages = "5712--5717",
booktitle = "2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012",

}

TY - GEN

T1 - Validation of accuracy of liver model with temperature-dependent thermal conductivity by comparing the simulation and in vitro RF ablation experiment

AU - Watanabe, Hiroki

AU - Yamazaki, Nozomu

AU - Isobe, Yosuke

AU - Lu, Xiaowei

AU - Kobayashi, Yo

AU - Miyashita, Tomoyuki

AU - Ohdaira, Takeshi

AU - Hashizume, Makoto

AU - Fujie, Masakatsu G.

PY - 2012/12/14

Y1 - 2012/12/14

N2 - Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

AB - Radiofrequency (RF) ablation is increasingly used to treat cancer because it is minimally invasive. However, it is difficult for operators to control precisely the formation of coagulation zones because of the inadequacies of imaging modalities. To overcome this limitation, we previously proposed a model-based robotic ablation system that can create the required size and shape of coagulation zone based on the dimensions of the tumor. At the heart of such a robotic system is a precise temperature distribution simulator for RF ablation. In this article, we evaluated the simulation accuracy of two numerical simulation liver models, one using a constant thermal conductivity value and the other using temperature-dependent thermal conductivity values, compared with temperatures obtained using in vitro experiments. The liver model that reflected the temperature dependence of thermal conductivity did not result in a large increase of simulation accuracy compared with the temperature-independent model in the temperature range achieved during clinical RF ablation.

UR - http://www.scopus.com/inward/record.url?scp=84870795305&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84870795305&partnerID=8YFLogxK

U2 - 10.1109/EMBC.2012.6347292

DO - 10.1109/EMBC.2012.6347292

M3 - Conference contribution

C2 - 23367227

AN - SCOPUS:84870795305

SN - 9781424441198

T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS

SP - 5712

EP - 5717

BT - 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012

ER -