A combination of the finite element analysis and experimental indentation via the cornea

Alireza Karimi, Reza Razaghi, Toshihiro Sera, Susumu Kudo

研究成果: ジャーナルへの寄稿記事

2 引用 (Scopus)

抄録

The purpose of this study was to perform a set of experimental indentation test to certify our proposed eye model enables to have a better deformation assessment for the eye globe under the indentation load compared to other eye models. To do that, twenty-four enucleated human globes were removed from the cadavers. A screw at 5 different loading rates indented to the eye globes and the resulting macroscopic force-displacement as a result of the deformation in the apex of the cornea was measured. The experimental results revealed significantly higher stiffness, elastic modulus, and maximum force for the globe at higher loading rates (50 and 100 mm/min) (n = 4 globes, p < 0.05, post hoc Scheffe method) compared to the lower ones (5, 10, and 20 mm/min). The mean stiffness, elastic modulus as well as the mean maximum force of 1.64 ± 0.38 N/mm, 303.40 ± 111.10 kPa, and 53.88 ± 17.63 N (Mean ± SD) were observed for the eye globes under all loading rates, respectively. Our eye model due to incorporating the anterior (cornea, aqueous body, and iris) and posterior (sclera, retina, and vitreous body) components showed a good agreement with force-displacement diagrams compared to that of the experimental results not only at lower but also at higher loading rates.

元の言語英語
ページ(範囲)146-154
ページ数9
ジャーナルJournal of the Mechanical Behavior of Biomedical Materials
90
DOI
出版物ステータス出版済み - 2 1 2019

Fingerprint

Indentation
Finite element method
Elastic moduli
Stiffness

All Science Journal Classification (ASJC) codes

  • Biomaterials
  • Biomedical Engineering
  • Mechanics of Materials

これを引用

A combination of the finite element analysis and experimental indentation via the cornea. / Karimi, Alireza; Razaghi, Reza; Sera, Toshihiro; Kudo, Susumu.

:: Journal of the Mechanical Behavior of Biomedical Materials, 巻 90, 01.02.2019, p. 146-154.

研究成果: ジャーナルへの寄稿記事

@article{0bc26d0b70bf4fbf986dd43f1cadd568,
title = "A combination of the finite element analysis and experimental indentation via the cornea",
abstract = "The purpose of this study was to perform a set of experimental indentation test to certify our proposed eye model enables to have a better deformation assessment for the eye globe under the indentation load compared to other eye models. To do that, twenty-four enucleated human globes were removed from the cadavers. A screw at 5 different loading rates indented to the eye globes and the resulting macroscopic force-displacement as a result of the deformation in the apex of the cornea was measured. The experimental results revealed significantly higher stiffness, elastic modulus, and maximum force for the globe at higher loading rates (50 and 100 mm/min) (n = 4 globes, p < 0.05, post hoc Scheffe method) compared to the lower ones (5, 10, and 20 mm/min). The mean stiffness, elastic modulus as well as the mean maximum force of 1.64 ± 0.38 N/mm, 303.40 ± 111.10 kPa, and 53.88 ± 17.63 N (Mean ± SD) were observed for the eye globes under all loading rates, respectively. Our eye model due to incorporating the anterior (cornea, aqueous body, and iris) and posterior (sclera, retina, and vitreous body) components showed a good agreement with force-displacement diagrams compared to that of the experimental results not only at lower but also at higher loading rates.",
author = "Alireza Karimi and Reza Razaghi and Toshihiro Sera and Susumu Kudo",
year = "2019",
month = "2",
day = "1",
doi = "10.1016/j.jmbbm.2018.10.017",
language = "English",
volume = "90",
pages = "146--154",
journal = "Journal of the Mechanical Behavior of Biomedical Materials",
issn = "1751-6161",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - A combination of the finite element analysis and experimental indentation via the cornea

AU - Karimi, Alireza

AU - Razaghi, Reza

AU - Sera, Toshihiro

AU - Kudo, Susumu

PY - 2019/2/1

Y1 - 2019/2/1

N2 - The purpose of this study was to perform a set of experimental indentation test to certify our proposed eye model enables to have a better deformation assessment for the eye globe under the indentation load compared to other eye models. To do that, twenty-four enucleated human globes were removed from the cadavers. A screw at 5 different loading rates indented to the eye globes and the resulting macroscopic force-displacement as a result of the deformation in the apex of the cornea was measured. The experimental results revealed significantly higher stiffness, elastic modulus, and maximum force for the globe at higher loading rates (50 and 100 mm/min) (n = 4 globes, p < 0.05, post hoc Scheffe method) compared to the lower ones (5, 10, and 20 mm/min). The mean stiffness, elastic modulus as well as the mean maximum force of 1.64 ± 0.38 N/mm, 303.40 ± 111.10 kPa, and 53.88 ± 17.63 N (Mean ± SD) were observed for the eye globes under all loading rates, respectively. Our eye model due to incorporating the anterior (cornea, aqueous body, and iris) and posterior (sclera, retina, and vitreous body) components showed a good agreement with force-displacement diagrams compared to that of the experimental results not only at lower but also at higher loading rates.

AB - The purpose of this study was to perform a set of experimental indentation test to certify our proposed eye model enables to have a better deformation assessment for the eye globe under the indentation load compared to other eye models. To do that, twenty-four enucleated human globes were removed from the cadavers. A screw at 5 different loading rates indented to the eye globes and the resulting macroscopic force-displacement as a result of the deformation in the apex of the cornea was measured. The experimental results revealed significantly higher stiffness, elastic modulus, and maximum force for the globe at higher loading rates (50 and 100 mm/min) (n = 4 globes, p < 0.05, post hoc Scheffe method) compared to the lower ones (5, 10, and 20 mm/min). The mean stiffness, elastic modulus as well as the mean maximum force of 1.64 ± 0.38 N/mm, 303.40 ± 111.10 kPa, and 53.88 ± 17.63 N (Mean ± SD) were observed for the eye globes under all loading rates, respectively. Our eye model due to incorporating the anterior (cornea, aqueous body, and iris) and posterior (sclera, retina, and vitreous body) components showed a good agreement with force-displacement diagrams compared to that of the experimental results not only at lower but also at higher loading rates.

UR - http://www.scopus.com/inward/record.url?scp=85055176132&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055176132&partnerID=8YFLogxK

U2 - 10.1016/j.jmbbm.2018.10.017

DO - 10.1016/j.jmbbm.2018.10.017

M3 - Article

VL - 90

SP - 146

EP - 154

JO - Journal of the Mechanical Behavior of Biomedical Materials

JF - Journal of the Mechanical Behavior of Biomedical Materials

SN - 1751-6161