A simplified numerical model for evaporative cooling by water spray over roof surfaces

Ajaya ketan Nayak, Aya Hagishima, Jun Tanimoto

研究成果: ジャーナルへの寄稿記事

抄録

Evaporative cooling is a well-known passive technique adopted especially in hot and dry climatic regions. This paper presents a simplified numerical model to assess the impact of water spray over roof surfaces on the building thermal load. First, we performed a series of long-term outdoor measurements of heat fluxes from an asphalt pavement and roof top of a laboratory building waterproofed by asphalt sheet. Based on the measured data, a correlation is proposed to estimate the evaporation rate of the concerned surfaces after rain showers. A simplified numerical model is then developed using this correlation based on the unsteady heat transfer to analyze the effect of precipitation and artificial water spray on the roof of the laboratory building. Simulation is performed with the help MATLAB using the hourly weather data from Fukuoka, Japan, and the simulated results are found to be in correspondence with the measured data. Finally, the cooling effect achieved by varying the amount and rate of water spray over the roof is compared to find out the optimum spraying conditions. The novelty of this study is that, in this model, the evaporation rate can be expressed in terms of the evaporation ratio, which is defined as a function of the water content of the surface layer of the roof. The water content of the surface layer can be obtained by the water balance equation, which is coupled dynamically with conductive equations. This procedure can drastically reduce the calculation load compared to the conventionally applied simultaneous hygrothermal transfer equation.

元の言語英語
記事番号114514
ジャーナルApplied Thermal Engineering
165
DOI
出版物ステータス出版済み - 1 25 2020

Fingerprint

Roofs
Numerical models
Cooling
Evaporation
Water
Water content
Asphalt pavements
Spraying
Thermal load
Asphalt
MATLAB
Rain
Heat flux
Heat transfer

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Industrial and Manufacturing Engineering

これを引用

A simplified numerical model for evaporative cooling by water spray over roof surfaces. / Nayak, Ajaya ketan; Hagishima, Aya; Tanimoto, Jun.

:: Applied Thermal Engineering, 巻 165, 114514, 25.01.2020.

研究成果: ジャーナルへの寄稿記事

@article{97ce1b05c5404509826b602ea8fb61b6,
title = "A simplified numerical model for evaporative cooling by water spray over roof surfaces",
abstract = "Evaporative cooling is a well-known passive technique adopted especially in hot and dry climatic regions. This paper presents a simplified numerical model to assess the impact of water spray over roof surfaces on the building thermal load. First, we performed a series of long-term outdoor measurements of heat fluxes from an asphalt pavement and roof top of a laboratory building waterproofed by asphalt sheet. Based on the measured data, a correlation is proposed to estimate the evaporation rate of the concerned surfaces after rain showers. A simplified numerical model is then developed using this correlation based on the unsteady heat transfer to analyze the effect of precipitation and artificial water spray on the roof of the laboratory building. Simulation is performed with the help MATLAB using the hourly weather data from Fukuoka, Japan, and the simulated results are found to be in correspondence with the measured data. Finally, the cooling effect achieved by varying the amount and rate of water spray over the roof is compared to find out the optimum spraying conditions. The novelty of this study is that, in this model, the evaporation rate can be expressed in terms of the evaporation ratio, which is defined as a function of the water content of the surface layer of the roof. The water content of the surface layer can be obtained by the water balance equation, which is coupled dynamically with conductive equations. This procedure can drastically reduce the calculation load compared to the conventionally applied simultaneous hygrothermal transfer equation.",
author = "Nayak, {Ajaya ketan} and Aya Hagishima and Jun Tanimoto",
year = "2020",
month = "1",
day = "25",
doi = "10.1016/j.applthermaleng.2019.114514",
language = "English",
volume = "165",
journal = "Applied Thermal Engineering",
issn = "1359-4311",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - A simplified numerical model for evaporative cooling by water spray over roof surfaces

AU - Nayak, Ajaya ketan

AU - Hagishima, Aya

AU - Tanimoto, Jun

PY - 2020/1/25

Y1 - 2020/1/25

N2 - Evaporative cooling is a well-known passive technique adopted especially in hot and dry climatic regions. This paper presents a simplified numerical model to assess the impact of water spray over roof surfaces on the building thermal load. First, we performed a series of long-term outdoor measurements of heat fluxes from an asphalt pavement and roof top of a laboratory building waterproofed by asphalt sheet. Based on the measured data, a correlation is proposed to estimate the evaporation rate of the concerned surfaces after rain showers. A simplified numerical model is then developed using this correlation based on the unsteady heat transfer to analyze the effect of precipitation and artificial water spray on the roof of the laboratory building. Simulation is performed with the help MATLAB using the hourly weather data from Fukuoka, Japan, and the simulated results are found to be in correspondence with the measured data. Finally, the cooling effect achieved by varying the amount and rate of water spray over the roof is compared to find out the optimum spraying conditions. The novelty of this study is that, in this model, the evaporation rate can be expressed in terms of the evaporation ratio, which is defined as a function of the water content of the surface layer of the roof. The water content of the surface layer can be obtained by the water balance equation, which is coupled dynamically with conductive equations. This procedure can drastically reduce the calculation load compared to the conventionally applied simultaneous hygrothermal transfer equation.

AB - Evaporative cooling is a well-known passive technique adopted especially in hot and dry climatic regions. This paper presents a simplified numerical model to assess the impact of water spray over roof surfaces on the building thermal load. First, we performed a series of long-term outdoor measurements of heat fluxes from an asphalt pavement and roof top of a laboratory building waterproofed by asphalt sheet. Based on the measured data, a correlation is proposed to estimate the evaporation rate of the concerned surfaces after rain showers. A simplified numerical model is then developed using this correlation based on the unsteady heat transfer to analyze the effect of precipitation and artificial water spray on the roof of the laboratory building. Simulation is performed with the help MATLAB using the hourly weather data from Fukuoka, Japan, and the simulated results are found to be in correspondence with the measured data. Finally, the cooling effect achieved by varying the amount and rate of water spray over the roof is compared to find out the optimum spraying conditions. The novelty of this study is that, in this model, the evaporation rate can be expressed in terms of the evaporation ratio, which is defined as a function of the water content of the surface layer of the roof. The water content of the surface layer can be obtained by the water balance equation, which is coupled dynamically with conductive equations. This procedure can drastically reduce the calculation load compared to the conventionally applied simultaneous hygrothermal transfer equation.

UR - http://www.scopus.com/inward/record.url?scp=85074176862&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85074176862&partnerID=8YFLogxK

U2 - 10.1016/j.applthermaleng.2019.114514

DO - 10.1016/j.applthermaleng.2019.114514

M3 - Article

AN - SCOPUS:85074176862

VL - 165

JO - Applied Thermal Engineering

JF - Applied Thermal Engineering

SN - 1359-4311

M1 - 114514

ER -