A study on connections of concrete filled steel tubes by using built-in steel bars

Akihiko Kawano, Qiyun Qiao, Shintaro Matsuo, Toshihiko Ninakawa

研究成果: 著書/レポートタイプへの貢献会議での発言

抄録

From 2006, authors started a series of experimental and analytical studies to establish a design method for a new connection system of concrete filled steel tube (CFT) by using built-in reinforcing steel bars (CFTR). Among the series, a pullout test of the built-in steel bars from the CFTRs has been early performed, which is orientated as a fundamental study for the connections of CFTR [1]. In the pullout test study, it is clarified that the influence of tube shapes (square and circular), the stress transfer capacities of bond by steel bars, ring bands in steel tubes and anchor plates of steel bars. The new connection system of CFTR may apply to an exposed-type CFT column base, where the built-in high strength steel bars contribute to transfer the axial force, bending moment and shear force from a CFT column to the foundation [2, 3]. The column base strength is much increased by the built-in steel bars. In other words, the built-in steel bars make the base plate and anchor bolts compact without any strength reduction in the column base. A stable elastic-plastic behavior is observed in the CFTR column base, and an evaluation method of the ultimate strengths is proposed for that. A further improved CFTR column base is the base without any base plate (non-base-plate CFTR column base), so that all of the stresses can be transferred through the built-in high strength steel bars [4]. A stable hysteretic behavior is observed in the column base, and the evaluation method of the ultimate strength is also proposed. It is noteworthy that the non-base-plate CFTR column base is applicable to the super high strength steel, because the base system does not require any full penetration welding, which sometimes causes brittle fracture in super high strength steel.

元の言語英語
ホスト出版物のタイトルSustainable Development of Urban Environment and Building Material
ページ1704-1723
ページ数20
DOI
出版物ステータス出版済み - 1 1 2012
イベント4th International Conference on Technology of Architecture and Structure, ICTAS 2011 - Xi'an, 中国
継続期間: 9 22 20119 24 2011

出版物シリーズ

名前Advanced Materials Research
374-377
ISSN(印刷物)1022-6680

その他

その他4th International Conference on Technology of Architecture and Structure, ICTAS 2011
中国
Xi'an
期間9/22/119/24/11

Fingerprint

Concretes
Steel
High strength steel
Anchor bolts
Brittle fracture
Bending moments
Anchors
Welding
Plastics

All Science Journal Classification (ASJC) codes

  • Engineering(all)

これを引用

Kawano, A., Qiao, Q., Matsuo, S., & Ninakawa, T. (2012). A study on connections of concrete filled steel tubes by using built-in steel bars. : Sustainable Development of Urban Environment and Building Material (pp. 1704-1723). (Advanced Materials Research; 巻数 374-377). https://doi.org/10.4028/www.scientific.net/AMR.374-377.1704

A study on connections of concrete filled steel tubes by using built-in steel bars. / Kawano, Akihiko; Qiao, Qiyun; Matsuo, Shintaro; Ninakawa, Toshihiko.

Sustainable Development of Urban Environment and Building Material. 2012. p. 1704-1723 (Advanced Materials Research; 巻 374-377).

研究成果: 著書/レポートタイプへの貢献会議での発言

Kawano, A, Qiao, Q, Matsuo, S & Ninakawa, T 2012, A study on connections of concrete filled steel tubes by using built-in steel bars. : Sustainable Development of Urban Environment and Building Material. Advanced Materials Research, 巻. 374-377, pp. 1704-1723, 4th International Conference on Technology of Architecture and Structure, ICTAS 2011, Xi'an, 中国, 9/22/11. https://doi.org/10.4028/www.scientific.net/AMR.374-377.1704
Kawano A, Qiao Q, Matsuo S, Ninakawa T. A study on connections of concrete filled steel tubes by using built-in steel bars. : Sustainable Development of Urban Environment and Building Material. 2012. p. 1704-1723. (Advanced Materials Research). https://doi.org/10.4028/www.scientific.net/AMR.374-377.1704
Kawano, Akihiko ; Qiao, Qiyun ; Matsuo, Shintaro ; Ninakawa, Toshihiko. / A study on connections of concrete filled steel tubes by using built-in steel bars. Sustainable Development of Urban Environment and Building Material. 2012. pp. 1704-1723 (Advanced Materials Research).
@inproceedings{1f3dd0cfd0da40b28ab249473406abc6,
title = "A study on connections of concrete filled steel tubes by using built-in steel bars",
abstract = "From 2006, authors started a series of experimental and analytical studies to establish a design method for a new connection system of concrete filled steel tube (CFT) by using built-in reinforcing steel bars (CFTR). Among the series, a pullout test of the built-in steel bars from the CFTRs has been early performed, which is orientated as a fundamental study for the connections of CFTR [1]. In the pullout test study, it is clarified that the influence of tube shapes (square and circular), the stress transfer capacities of bond by steel bars, ring bands in steel tubes and anchor plates of steel bars. The new connection system of CFTR may apply to an exposed-type CFT column base, where the built-in high strength steel bars contribute to transfer the axial force, bending moment and shear force from a CFT column to the foundation [2, 3]. The column base strength is much increased by the built-in steel bars. In other words, the built-in steel bars make the base plate and anchor bolts compact without any strength reduction in the column base. A stable elastic-plastic behavior is observed in the CFTR column base, and an evaluation method of the ultimate strengths is proposed for that. A further improved CFTR column base is the base without any base plate (non-base-plate CFTR column base), so that all of the stresses can be transferred through the built-in high strength steel bars [4]. A stable hysteretic behavior is observed in the column base, and the evaluation method of the ultimate strength is also proposed. It is noteworthy that the non-base-plate CFTR column base is applicable to the super high strength steel, because the base system does not require any full penetration welding, which sometimes causes brittle fracture in super high strength steel.",
author = "Akihiko Kawano and Qiyun Qiao and Shintaro Matsuo and Toshihiko Ninakawa",
year = "2012",
month = "1",
day = "1",
doi = "10.4028/www.scientific.net/AMR.374-377.1704",
language = "English",
isbn = "9783037852798",
series = "Advanced Materials Research",
pages = "1704--1723",
booktitle = "Sustainable Development of Urban Environment and Building Material",

}

TY - GEN

T1 - A study on connections of concrete filled steel tubes by using built-in steel bars

AU - Kawano, Akihiko

AU - Qiao, Qiyun

AU - Matsuo, Shintaro

AU - Ninakawa, Toshihiko

PY - 2012/1/1

Y1 - 2012/1/1

N2 - From 2006, authors started a series of experimental and analytical studies to establish a design method for a new connection system of concrete filled steel tube (CFT) by using built-in reinforcing steel bars (CFTR). Among the series, a pullout test of the built-in steel bars from the CFTRs has been early performed, which is orientated as a fundamental study for the connections of CFTR [1]. In the pullout test study, it is clarified that the influence of tube shapes (square and circular), the stress transfer capacities of bond by steel bars, ring bands in steel tubes and anchor plates of steel bars. The new connection system of CFTR may apply to an exposed-type CFT column base, where the built-in high strength steel bars contribute to transfer the axial force, bending moment and shear force from a CFT column to the foundation [2, 3]. The column base strength is much increased by the built-in steel bars. In other words, the built-in steel bars make the base plate and anchor bolts compact without any strength reduction in the column base. A stable elastic-plastic behavior is observed in the CFTR column base, and an evaluation method of the ultimate strengths is proposed for that. A further improved CFTR column base is the base without any base plate (non-base-plate CFTR column base), so that all of the stresses can be transferred through the built-in high strength steel bars [4]. A stable hysteretic behavior is observed in the column base, and the evaluation method of the ultimate strength is also proposed. It is noteworthy that the non-base-plate CFTR column base is applicable to the super high strength steel, because the base system does not require any full penetration welding, which sometimes causes brittle fracture in super high strength steel.

AB - From 2006, authors started a series of experimental and analytical studies to establish a design method for a new connection system of concrete filled steel tube (CFT) by using built-in reinforcing steel bars (CFTR). Among the series, a pullout test of the built-in steel bars from the CFTRs has been early performed, which is orientated as a fundamental study for the connections of CFTR [1]. In the pullout test study, it is clarified that the influence of tube shapes (square and circular), the stress transfer capacities of bond by steel bars, ring bands in steel tubes and anchor plates of steel bars. The new connection system of CFTR may apply to an exposed-type CFT column base, where the built-in high strength steel bars contribute to transfer the axial force, bending moment and shear force from a CFT column to the foundation [2, 3]. The column base strength is much increased by the built-in steel bars. In other words, the built-in steel bars make the base plate and anchor bolts compact without any strength reduction in the column base. A stable elastic-plastic behavior is observed in the CFTR column base, and an evaluation method of the ultimate strengths is proposed for that. A further improved CFTR column base is the base without any base plate (non-base-plate CFTR column base), so that all of the stresses can be transferred through the built-in high strength steel bars [4]. A stable hysteretic behavior is observed in the column base, and the evaluation method of the ultimate strength is also proposed. It is noteworthy that the non-base-plate CFTR column base is applicable to the super high strength steel, because the base system does not require any full penetration welding, which sometimes causes brittle fracture in super high strength steel.

UR - http://www.scopus.com/inward/record.url?scp=82055192142&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82055192142&partnerID=8YFLogxK

U2 - 10.4028/www.scientific.net/AMR.374-377.1704

DO - 10.4028/www.scientific.net/AMR.374-377.1704

M3 - Conference contribution

AN - SCOPUS:82055192142

SN - 9783037852798

T3 - Advanced Materials Research

SP - 1704

EP - 1723

BT - Sustainable Development of Urban Environment and Building Material

ER -