A study on the improvement of measurement accuracy of the three-dimensional electromagnetic articulography

研究成果: ジャーナルへの寄稿記事

抄録

The alignment of the transmitter coils for the three-dimensional electromagnetic articulography (3D-EMA), an instrument used to measure articulatory movements, was studied. The receiver coils of the 3D-EMA are used as position markers and are placed in an alternating magnetic field produced by multiple transmitter coils. The estimation of state (the position and orientation) of each receiver coil is based on the minimization of signal error between the measured and predicted receiver signals using a model of the magnetic field. Previous studies report a noticeable increase in the position estimation error at a specific portion of the measurement region irrespective of small signal error values. The existence of non-uniqueness in the position estimation problem is hypothesized to be the cause of this problem. To resolve the problem, we optimized the alignment of the transmitter coils by maximizing the difference between the receiver signals at any two states in the measurement region and evaluated the alignment using a computer simulation and an experiment. As a result, a measurement accuracy of approximately 0.4 mm was obtained.

元の言語英語
ページ(範囲)726-730
ページ数5
ジャーナルUnknown Journal
出版物ステータス出版済み - 2014

Fingerprint

Coil
Signal receivers
Transmitters
Receiver
Three-dimensional
Transmitter
Alignment
Magnetic fields
magnetic field
Error analysis
Magnetic Field
computer simulation
Nonuniqueness
Estimation Error
Computer simulation
Resolve
Computer Simulation
Electromagnetic
Experiments
alignment

All Science Journal Classification (ASJC) codes

  • Language and Linguistics
  • Human-Computer Interaction
  • Signal Processing
  • Software
  • Modelling and Simulation

これを引用

@article{705e7369b7bb45aeb7c284820329c11f,
title = "A study on the improvement of measurement accuracy of the three-dimensional electromagnetic articulography",
abstract = "The alignment of the transmitter coils for the three-dimensional electromagnetic articulography (3D-EMA), an instrument used to measure articulatory movements, was studied. The receiver coils of the 3D-EMA are used as position markers and are placed in an alternating magnetic field produced by multiple transmitter coils. The estimation of state (the position and orientation) of each receiver coil is based on the minimization of signal error between the measured and predicted receiver signals using a model of the magnetic field. Previous studies report a noticeable increase in the position estimation error at a specific portion of the measurement region irrespective of small signal error values. The existence of non-uniqueness in the position estimation problem is hypothesized to be the cause of this problem. To resolve the problem, we optimized the alignment of the transmitter coils by maximizing the difference between the receiver signals at any two states in the measurement region and evaluated the alignment using a computer simulation and an experiment. As a result, a measurement accuracy of approximately 0.4 mm was obtained.",
author = "Hidetsugu Uchida and Kohei Wakamiya and Tokihiko Kaburagi",
year = "2014",
language = "English",
pages = "726--730",
journal = "Quaternary International",
issn = "1040-6182",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - A study on the improvement of measurement accuracy of the three-dimensional electromagnetic articulography

AU - Uchida, Hidetsugu

AU - Wakamiya, Kohei

AU - Kaburagi, Tokihiko

PY - 2014

Y1 - 2014

N2 - The alignment of the transmitter coils for the three-dimensional electromagnetic articulography (3D-EMA), an instrument used to measure articulatory movements, was studied. The receiver coils of the 3D-EMA are used as position markers and are placed in an alternating magnetic field produced by multiple transmitter coils. The estimation of state (the position and orientation) of each receiver coil is based on the minimization of signal error between the measured and predicted receiver signals using a model of the magnetic field. Previous studies report a noticeable increase in the position estimation error at a specific portion of the measurement region irrespective of small signal error values. The existence of non-uniqueness in the position estimation problem is hypothesized to be the cause of this problem. To resolve the problem, we optimized the alignment of the transmitter coils by maximizing the difference between the receiver signals at any two states in the measurement region and evaluated the alignment using a computer simulation and an experiment. As a result, a measurement accuracy of approximately 0.4 mm was obtained.

AB - The alignment of the transmitter coils for the three-dimensional electromagnetic articulography (3D-EMA), an instrument used to measure articulatory movements, was studied. The receiver coils of the 3D-EMA are used as position markers and are placed in an alternating magnetic field produced by multiple transmitter coils. The estimation of state (the position and orientation) of each receiver coil is based on the minimization of signal error between the measured and predicted receiver signals using a model of the magnetic field. Previous studies report a noticeable increase in the position estimation error at a specific portion of the measurement region irrespective of small signal error values. The existence of non-uniqueness in the position estimation problem is hypothesized to be the cause of this problem. To resolve the problem, we optimized the alignment of the transmitter coils by maximizing the difference between the receiver signals at any two states in the measurement region and evaluated the alignment using a computer simulation and an experiment. As a result, a measurement accuracy of approximately 0.4 mm was obtained.

UR - http://www.scopus.com/inward/record.url?scp=84910104149&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84910104149&partnerID=8YFLogxK

M3 - Article

SP - 726

EP - 730

JO - Quaternary International

JF - Quaternary International

SN - 1040-6182

ER -