Air-flow-based single-cell dispensing system

Tomohiro Kawahara, Shigeo Ohashi, Masaya Hagiwara, Yoko Yamanishi, Fumihito Arai

研究成果: ジャーナルへの寄稿記事

7 引用 (Scopus)

抄録

We discuss a design and fabrication approach to increase the success rate of single-cell dispensing. Two pairs of capacitance sensors are placed in a biochip to detect the flow velocity of cells and air pressure is applied to eject cells by synchronizing the timing. A comprehensive design theory, which takes into account the back-pressure caused by the air pressure, the response time of the system, the sensor properties and the delay of the dispensing from the air pressure, is developed in order to minimize the disturbance of the system and maximize the throughput of the ejection system. Then, the system theoretically has a capability to eject 3 cells/s and the maximum flow velocity is 10 mm/s. The novelty of the system is that the biochip is disposable, which is unlike the conventional mechanical inkjet system; because the biochip is low cost and disposable this prevents contamination and means the drive system is reusable. Finally, we succeeded in automatic dispensing of a single polystyrene bead (100 μm) from a biochip to a culture well atmosphere using the developed cell ejection system with a success rate of 50%. Furthermore, we also succeeded in single swine oocyte dispensing by using the developed system.

元の言語英語
ページ(範囲)291-306
ページ数16
ジャーナルAdvanced Robotics
26
発行部数3-4
DOI
出版物ステータス出版済み - 3 12 2012
外部発表Yes

Fingerprint

Biochips
Air
Flow velocity
Sensors
Polystyrenes
Contamination
Capacitance
Throughput
Fabrication
Costs

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Software
  • Human-Computer Interaction
  • Hardware and Architecture
  • Computer Science Applications

これを引用

Kawahara, T., Ohashi, S., Hagiwara, M., Yamanishi, Y., & Arai, F. (2012). Air-flow-based single-cell dispensing system. Advanced Robotics, 26(3-4), 291-306. https://doi.org/10.1163/156855311X614572

Air-flow-based single-cell dispensing system. / Kawahara, Tomohiro; Ohashi, Shigeo; Hagiwara, Masaya; Yamanishi, Yoko; Arai, Fumihito.

:: Advanced Robotics, 巻 26, 番号 3-4, 12.03.2012, p. 291-306.

研究成果: ジャーナルへの寄稿記事

Kawahara, T, Ohashi, S, Hagiwara, M, Yamanishi, Y & Arai, F 2012, 'Air-flow-based single-cell dispensing system', Advanced Robotics, 巻. 26, 番号 3-4, pp. 291-306. https://doi.org/10.1163/156855311X614572
Kawahara, Tomohiro ; Ohashi, Shigeo ; Hagiwara, Masaya ; Yamanishi, Yoko ; Arai, Fumihito. / Air-flow-based single-cell dispensing system. :: Advanced Robotics. 2012 ; 巻 26, 番号 3-4. pp. 291-306.
@article{1741e542dee5468790d0a9f150d021a7,
title = "Air-flow-based single-cell dispensing system",
abstract = "We discuss a design and fabrication approach to increase the success rate of single-cell dispensing. Two pairs of capacitance sensors are placed in a biochip to detect the flow velocity of cells and air pressure is applied to eject cells by synchronizing the timing. A comprehensive design theory, which takes into account the back-pressure caused by the air pressure, the response time of the system, the sensor properties and the delay of the dispensing from the air pressure, is developed in order to minimize the disturbance of the system and maximize the throughput of the ejection system. Then, the system theoretically has a capability to eject 3 cells/s and the maximum flow velocity is 10 mm/s. The novelty of the system is that the biochip is disposable, which is unlike the conventional mechanical inkjet system; because the biochip is low cost and disposable this prevents contamination and means the drive system is reusable. Finally, we succeeded in automatic dispensing of a single polystyrene bead (100 μm) from a biochip to a culture well atmosphere using the developed cell ejection system with a success rate of 50{\%}. Furthermore, we also succeeded in single swine oocyte dispensing by using the developed system.",
author = "Tomohiro Kawahara and Shigeo Ohashi and Masaya Hagiwara and Yoko Yamanishi and Fumihito Arai",
year = "2012",
month = "3",
day = "12",
doi = "10.1163/156855311X614572",
language = "English",
volume = "26",
pages = "291--306",
journal = "Advanced Robotics",
issn = "0169-1864",
publisher = "Taylor and Francis Ltd.",
number = "3-4",

}

TY - JOUR

T1 - Air-flow-based single-cell dispensing system

AU - Kawahara, Tomohiro

AU - Ohashi, Shigeo

AU - Hagiwara, Masaya

AU - Yamanishi, Yoko

AU - Arai, Fumihito

PY - 2012/3/12

Y1 - 2012/3/12

N2 - We discuss a design and fabrication approach to increase the success rate of single-cell dispensing. Two pairs of capacitance sensors are placed in a biochip to detect the flow velocity of cells and air pressure is applied to eject cells by synchronizing the timing. A comprehensive design theory, which takes into account the back-pressure caused by the air pressure, the response time of the system, the sensor properties and the delay of the dispensing from the air pressure, is developed in order to minimize the disturbance of the system and maximize the throughput of the ejection system. Then, the system theoretically has a capability to eject 3 cells/s and the maximum flow velocity is 10 mm/s. The novelty of the system is that the biochip is disposable, which is unlike the conventional mechanical inkjet system; because the biochip is low cost and disposable this prevents contamination and means the drive system is reusable. Finally, we succeeded in automatic dispensing of a single polystyrene bead (100 μm) from a biochip to a culture well atmosphere using the developed cell ejection system with a success rate of 50%. Furthermore, we also succeeded in single swine oocyte dispensing by using the developed system.

AB - We discuss a design and fabrication approach to increase the success rate of single-cell dispensing. Two pairs of capacitance sensors are placed in a biochip to detect the flow velocity of cells and air pressure is applied to eject cells by synchronizing the timing. A comprehensive design theory, which takes into account the back-pressure caused by the air pressure, the response time of the system, the sensor properties and the delay of the dispensing from the air pressure, is developed in order to minimize the disturbance of the system and maximize the throughput of the ejection system. Then, the system theoretically has a capability to eject 3 cells/s and the maximum flow velocity is 10 mm/s. The novelty of the system is that the biochip is disposable, which is unlike the conventional mechanical inkjet system; because the biochip is low cost and disposable this prevents contamination and means the drive system is reusable. Finally, we succeeded in automatic dispensing of a single polystyrene bead (100 μm) from a biochip to a culture well atmosphere using the developed cell ejection system with a success rate of 50%. Furthermore, we also succeeded in single swine oocyte dispensing by using the developed system.

UR - http://www.scopus.com/inward/record.url?scp=84857843433&partnerID=8YFLogxK