Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping

Yoshihiro Ito, Shigenobu Kainuma

研究成果: 著書/レポートタイプへの貢献会議での発言

抄録

It is important to devise a method of predicting the time-dependent corrosion behavior of structural steel members in order to ensure the safety of structures. However, there is currently no established method of predicting corrosion behavior in a wide variety of corrosive environments. In our previous research, a method for evaluating the corrosion behavior of unpainted steel plates using an atmospheric corrosion monitor (ACM) sensor was proposed. This method has been confirmed to be effective in high chloride environments. However, corrosion behavior in high carbon dioxide environments cannot currently be evaluated. Thus, the purpose of this study was to clarify the difference between the ACM output characteristics in chloride and carbon dioxide environments, and to investigate the application of ACM corrosion sensors to high carbon dioxide atmospheres. Exposure tests were carried out on unpainted steel plate inside plumbing in the Kobe Steel manufacturing plant. In addition, the environment was monitored using ACM sensors.

元の言語英語
ホスト出版物のタイトルEuropean Corrosion Congress 2011, EUROCORR 2011
ページ3290-3295
ページ数6
4
出版物ステータス出版済み - 2011
イベントEuropean Corrosion Congress 2011, EUROCORR 2011 - Stockholm, スウェーデン
継続期間: 9 4 20119 8 2011

その他

その他European Corrosion Congress 2011, EUROCORR 2011
スウェーデン
Stockholm
期間9/4/119/8/11

Fingerprint

Atmospheric corrosion
Caustics
Steel
monitors
corrosion
Gases
Corrosion
Carbon Dioxide
evaluation
sensors
Sensors
Carbon dioxide
gases
Chlorides
steels
carbon dioxide
Plumbing
chlorides
dioxides
safety

All Science Journal Classification (ASJC) codes

  • Colloid and Surface Chemistry
  • Surfaces and Interfaces

これを引用

Ito, Y., & Kainuma, S. (2011). Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping. : European Corrosion Congress 2011, EUROCORR 2011 (巻 4, pp. 3290-3295)

Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping. / Ito, Yoshihiro; Kainuma, Shigenobu.

European Corrosion Congress 2011, EUROCORR 2011. 巻 4 2011. p. 3290-3295.

研究成果: 著書/レポートタイプへの貢献会議での発言

Ito, Y & Kainuma, S 2011, Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping. : European Corrosion Congress 2011, EUROCORR 2011. 巻. 4, pp. 3290-3295, European Corrosion Congress 2011, EUROCORR 2011, Stockholm, スウェーデン, 9/4/11.
Ito Y, Kainuma S. Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping. : European Corrosion Congress 2011, EUROCORR 2011. 巻 4. 2011. p. 3290-3295
Ito, Yoshihiro ; Kainuma, Shigenobu. / Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping. European Corrosion Congress 2011, EUROCORR 2011. 巻 4 2011. pp. 3290-3295
@inproceedings{74d76680f4e1453a821dafbf38af3e01,
title = "Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping",
abstract = "It is important to devise a method of predicting the time-dependent corrosion behavior of structural steel members in order to ensure the safety of structures. However, there is currently no established method of predicting corrosion behavior in a wide variety of corrosive environments. In our previous research, a method for evaluating the corrosion behavior of unpainted steel plates using an atmospheric corrosion monitor (ACM) sensor was proposed. This method has been confirmed to be effective in high chloride environments. However, corrosion behavior in high carbon dioxide environments cannot currently be evaluated. Thus, the purpose of this study was to clarify the difference between the ACM output characteristics in chloride and carbon dioxide environments, and to investigate the application of ACM corrosion sensors to high carbon dioxide atmospheres. Exposure tests were carried out on unpainted steel plate inside plumbing in the Kobe Steel manufacturing plant. In addition, the environment was monitored using ACM sensors.",
author = "Yoshihiro Ito and Shigenobu Kainuma",
year = "2011",
language = "English",
isbn = "9781618394125",
volume = "4",
pages = "3290--3295",
booktitle = "European Corrosion Congress 2011, EUROCORR 2011",

}

TY - GEN

T1 - Applicability of an ACM type corrosion sensor to evaluations of corrosive environments in gas piping

AU - Ito, Yoshihiro

AU - Kainuma, Shigenobu

PY - 2011

Y1 - 2011

N2 - It is important to devise a method of predicting the time-dependent corrosion behavior of structural steel members in order to ensure the safety of structures. However, there is currently no established method of predicting corrosion behavior in a wide variety of corrosive environments. In our previous research, a method for evaluating the corrosion behavior of unpainted steel plates using an atmospheric corrosion monitor (ACM) sensor was proposed. This method has been confirmed to be effective in high chloride environments. However, corrosion behavior in high carbon dioxide environments cannot currently be evaluated. Thus, the purpose of this study was to clarify the difference between the ACM output characteristics in chloride and carbon dioxide environments, and to investigate the application of ACM corrosion sensors to high carbon dioxide atmospheres. Exposure tests were carried out on unpainted steel plate inside plumbing in the Kobe Steel manufacturing plant. In addition, the environment was monitored using ACM sensors.

AB - It is important to devise a method of predicting the time-dependent corrosion behavior of structural steel members in order to ensure the safety of structures. However, there is currently no established method of predicting corrosion behavior in a wide variety of corrosive environments. In our previous research, a method for evaluating the corrosion behavior of unpainted steel plates using an atmospheric corrosion monitor (ACM) sensor was proposed. This method has been confirmed to be effective in high chloride environments. However, corrosion behavior in high carbon dioxide environments cannot currently be evaluated. Thus, the purpose of this study was to clarify the difference between the ACM output characteristics in chloride and carbon dioxide environments, and to investigate the application of ACM corrosion sensors to high carbon dioxide atmospheres. Exposure tests were carried out on unpainted steel plate inside plumbing in the Kobe Steel manufacturing plant. In addition, the environment was monitored using ACM sensors.

UR - http://www.scopus.com/inward/record.url?scp=84860894394&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860894394&partnerID=8YFLogxK

M3 - Conference contribution

SN - 9781618394125

VL - 4

SP - 3290

EP - 3295

BT - European Corrosion Congress 2011, EUROCORR 2011

ER -