抄録
An active-clamp circuit is an effective method to suppress the switching surge and to realize the soft switching in switching dc-dc converters. Recently, the common-source type active-clamp forward converter was presented to enable easy gate drive with a direct connection of the sources of the two n-channel MOS-FET switches. In this paper, we apply the common-source type active-clamp circuit to various kinds of dc-dc converter topologies. The effectiveness of the common-mode noise reduction is experimentally confirmed and its mechanism is explained using an equivalent circuit.
本文言語 | 英語 |
---|---|
ページ(範囲) | 1321-1326 |
ページ数 | 6 |
ジャーナル | PESC Record - IEEE Annual Power Electronics Specialists Conference |
巻 | 3 |
出版ステータス | 出版済み - 8月 22 2003 |
イベント | 2003 IEEE 34th Annual Power Electronics Specialists Conference - Acapulco, NM, 米国 継続期間: 6月 15 2003 → 6月 19 2003 |
!!!All Science Journal Classification (ASJC) codes
- モデリングとシミュレーション
- 凝縮系物理学
- エネルギー工学および電力技術
- 電子工学および電気工学