Application of pulsed laser irradiation for removal of hydrogen retained in tungsten

Kentaro Hirata, Kenichiro Furumoto, Naoji Yamamoto, Tetsuo Tanabe

研究成果: ジャーナルへの寄稿記事

2 引用 (Scopus)

抄録

For the purpose of removal of tritium retained in tungsten (W), pulsed laser irradiation has been applied. The laser light used here was the fourth harmonic of Nd: YAG laser (wavelength; 266 nm, pulse width; 20 ps, pulse frequency; 10 Hz, laser energy up to 3 mJ/pulse). Samples were pure W plates and those saturated with D by D2+ ion implantation at room temperature with using a 2.5 keV ion gun. Released ions and molecules by the laser irradiation were measured by a time-of-flight mass spectrometer (TOFMS) and a quadrupole mass spectrometer (Q-mass), respectively. Ablation of W was observed by the laser irradiation with a deposited power density above 1.5 × 1011 W/cm2 (3 J/cm2/pulse) (an ablation threshold) and D removals below and above the ablation threshold were quite different. The most effective removal of tritium retained in W could be realized by the pulsed laser irradiation with the power density of just below the ablation threshold.

元の言語英語
ページ(範囲)298-301
ページ数4
ジャーナルJournal of Nuclear Materials
443
発行部数1-3
DOI
出版物ステータス出版済み - 8 28 2013

Fingerprint

Tungsten
Laser beam effects
Ablation
Pulsed lasers
ablation
Hydrogen
pulsed lasers
tungsten
Laser pulses
irradiation
Tritium
Mass spectrometers
hydrogen
tritium
mass spectrometers
lasers
thresholds
Lasers
radiant flux density
pulses

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Materials Science(all)

これを引用

Application of pulsed laser irradiation for removal of hydrogen retained in tungsten. / Hirata, Kentaro; Furumoto, Kenichiro; Yamamoto, Naoji; Tanabe, Tetsuo.

:: Journal of Nuclear Materials, 巻 443, 番号 1-3, 28.08.2013, p. 298-301.

研究成果: ジャーナルへの寄稿記事

Hirata, Kentaro ; Furumoto, Kenichiro ; Yamamoto, Naoji ; Tanabe, Tetsuo. / Application of pulsed laser irradiation for removal of hydrogen retained in tungsten. :: Journal of Nuclear Materials. 2013 ; 巻 443, 番号 1-3. pp. 298-301.
@article{20e08e35271e426b8cfb872962f14418,
title = "Application of pulsed laser irradiation for removal of hydrogen retained in tungsten",
abstract = "For the purpose of removal of tritium retained in tungsten (W), pulsed laser irradiation has been applied. The laser light used here was the fourth harmonic of Nd: YAG laser (wavelength; 266 nm, pulse width; 20 ps, pulse frequency; 10 Hz, laser energy up to 3 mJ/pulse). Samples were pure W plates and those saturated with D by D2+ ion implantation at room temperature with using a 2.5 keV ion gun. Released ions and molecules by the laser irradiation were measured by a time-of-flight mass spectrometer (TOFMS) and a quadrupole mass spectrometer (Q-mass), respectively. Ablation of W was observed by the laser irradiation with a deposited power density above 1.5 × 1011 W/cm2 (3 J/cm2/pulse) (an ablation threshold) and D removals below and above the ablation threshold were quite different. The most effective removal of tritium retained in W could be realized by the pulsed laser irradiation with the power density of just below the ablation threshold.",
author = "Kentaro Hirata and Kenichiro Furumoto and Naoji Yamamoto and Tetsuo Tanabe",
year = "2013",
month = "8",
day = "28",
doi = "10.1016/j.jnucmat.2013.07.047",
language = "English",
volume = "443",
pages = "298--301",
journal = "Journal of Nuclear Materials",
issn = "0022-3115",
publisher = "Elsevier",
number = "1-3",

}

TY - JOUR

T1 - Application of pulsed laser irradiation for removal of hydrogen retained in tungsten

AU - Hirata, Kentaro

AU - Furumoto, Kenichiro

AU - Yamamoto, Naoji

AU - Tanabe, Tetsuo

PY - 2013/8/28

Y1 - 2013/8/28

N2 - For the purpose of removal of tritium retained in tungsten (W), pulsed laser irradiation has been applied. The laser light used here was the fourth harmonic of Nd: YAG laser (wavelength; 266 nm, pulse width; 20 ps, pulse frequency; 10 Hz, laser energy up to 3 mJ/pulse). Samples were pure W plates and those saturated with D by D2+ ion implantation at room temperature with using a 2.5 keV ion gun. Released ions and molecules by the laser irradiation were measured by a time-of-flight mass spectrometer (TOFMS) and a quadrupole mass spectrometer (Q-mass), respectively. Ablation of W was observed by the laser irradiation with a deposited power density above 1.5 × 1011 W/cm2 (3 J/cm2/pulse) (an ablation threshold) and D removals below and above the ablation threshold were quite different. The most effective removal of tritium retained in W could be realized by the pulsed laser irradiation with the power density of just below the ablation threshold.

AB - For the purpose of removal of tritium retained in tungsten (W), pulsed laser irradiation has been applied. The laser light used here was the fourth harmonic of Nd: YAG laser (wavelength; 266 nm, pulse width; 20 ps, pulse frequency; 10 Hz, laser energy up to 3 mJ/pulse). Samples were pure W plates and those saturated with D by D2+ ion implantation at room temperature with using a 2.5 keV ion gun. Released ions and molecules by the laser irradiation were measured by a time-of-flight mass spectrometer (TOFMS) and a quadrupole mass spectrometer (Q-mass), respectively. Ablation of W was observed by the laser irradiation with a deposited power density above 1.5 × 1011 W/cm2 (3 J/cm2/pulse) (an ablation threshold) and D removals below and above the ablation threshold were quite different. The most effective removal of tritium retained in W could be realized by the pulsed laser irradiation with the power density of just below the ablation threshold.

UR - http://www.scopus.com/inward/record.url?scp=84882749828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84882749828&partnerID=8YFLogxK

U2 - 10.1016/j.jnucmat.2013.07.047

DO - 10.1016/j.jnucmat.2013.07.047

M3 - Article

AN - SCOPUS:84882749828

VL - 443

SP - 298

EP - 301

JO - Journal of Nuclear Materials

JF - Journal of Nuclear Materials

SN - 0022-3115

IS - 1-3

ER -