A new automatic visualization procedure for the oxygen saturation imaging from multi-spectral imaging of human retinal vessels has been proposed. Two-wavelength retinal fundus images at 545 and 560 nm, which were oxygen insensitive and oxygen sensitive, respectively, were captured by CCD cameras simultaneously through a beam splitter and interference filters. We applied a morphological processing technique to presume a distribution of incident light including the vessel parts and an optical density (OD) image of each wavelength image. And the OD ratio (OD560/OD545) image was calculated as a relative indicator of oxygen saturation. Furthermore, processing of line convergence index filter was adopted to identify the retinal vessels. Clear difference between retinal arteries and veins was observed in the automated imaging method. In addition, the decrease of oxygen saturation in the retinal artery without breathing could be monitored by the ODR. This method is possible to be applied to real-time monitoring for oxygen saturation of retinal vessels.

元の言語英語
記事番号71631N
ジャーナルProgress in Biomedical Optics and Imaging - Proceedings of SPIE
7163
DOI
出版物ステータス出版済み - 5 13 2009
イベントOphthalmic Technologies XIX - San Jose, CA, 米国
継続期間: 1 24 20091 26 2009

Fingerprint

Retinal Vessels
vessels
Oxygen
saturation
Imaging techniques
oxygen
Retinal Artery
Density (optical)
optical density
arteries
retinal images
Retinal Vein
filters
Wavelength
beam splitters
breathing
CCD cameras
Processing
veins
wavelengths

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

これを引用

Automated spectroscopic imaging of oxygen saturation in human retinal vessels. / Nakamura, Daisuke; Sueda, S.; Matsuoka, N.; Yoshinaga, Yukiyasu; Enaida, H.; Okada, T.; Ishibashi, Tatsuro.

:: Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 巻 7163, 71631N, 13.05.2009.

研究成果: ジャーナルへの寄稿Conference article

@article{feed0d9e427e4099ab37bacc5872fa04,
title = "Automated spectroscopic imaging of oxygen saturation in human retinal vessels",
abstract = "A new automatic visualization procedure for the oxygen saturation imaging from multi-spectral imaging of human retinal vessels has been proposed. Two-wavelength retinal fundus images at 545 and 560 nm, which were oxygen insensitive and oxygen sensitive, respectively, were captured by CCD cameras simultaneously through a beam splitter and interference filters. We applied a morphological processing technique to presume a distribution of incident light including the vessel parts and an optical density (OD) image of each wavelength image. And the OD ratio (OD560/OD545) image was calculated as a relative indicator of oxygen saturation. Furthermore, processing of line convergence index filter was adopted to identify the retinal vessels. Clear difference between retinal arteries and veins was observed in the automated imaging method. In addition, the decrease of oxygen saturation in the retinal artery without breathing could be monitored by the ODR. This method is possible to be applied to real-time monitoring for oxygen saturation of retinal vessels.",
author = "Daisuke Nakamura and S. Sueda and N. Matsuoka and Yukiyasu Yoshinaga and H. Enaida and T. Okada and Tatsuro Ishibashi",
year = "2009",
month = "5",
day = "13",
doi = "10.1117/12.807537",
language = "English",
volume = "7163",
journal = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
issn = "1605-7422",
publisher = "SPIE",

}

TY - JOUR

T1 - Automated spectroscopic imaging of oxygen saturation in human retinal vessels

AU - Nakamura, Daisuke

AU - Sueda, S.

AU - Matsuoka, N.

AU - Yoshinaga, Yukiyasu

AU - Enaida, H.

AU - Okada, T.

AU - Ishibashi, Tatsuro

PY - 2009/5/13

Y1 - 2009/5/13

N2 - A new automatic visualization procedure for the oxygen saturation imaging from multi-spectral imaging of human retinal vessels has been proposed. Two-wavelength retinal fundus images at 545 and 560 nm, which were oxygen insensitive and oxygen sensitive, respectively, were captured by CCD cameras simultaneously through a beam splitter and interference filters. We applied a morphological processing technique to presume a distribution of incident light including the vessel parts and an optical density (OD) image of each wavelength image. And the OD ratio (OD560/OD545) image was calculated as a relative indicator of oxygen saturation. Furthermore, processing of line convergence index filter was adopted to identify the retinal vessels. Clear difference between retinal arteries and veins was observed in the automated imaging method. In addition, the decrease of oxygen saturation in the retinal artery without breathing could be monitored by the ODR. This method is possible to be applied to real-time monitoring for oxygen saturation of retinal vessels.

AB - A new automatic visualization procedure for the oxygen saturation imaging from multi-spectral imaging of human retinal vessels has been proposed. Two-wavelength retinal fundus images at 545 and 560 nm, which were oxygen insensitive and oxygen sensitive, respectively, were captured by CCD cameras simultaneously through a beam splitter and interference filters. We applied a morphological processing technique to presume a distribution of incident light including the vessel parts and an optical density (OD) image of each wavelength image. And the OD ratio (OD560/OD545) image was calculated as a relative indicator of oxygen saturation. Furthermore, processing of line convergence index filter was adopted to identify the retinal vessels. Clear difference between retinal arteries and veins was observed in the automated imaging method. In addition, the decrease of oxygen saturation in the retinal artery without breathing could be monitored by the ODR. This method is possible to be applied to real-time monitoring for oxygen saturation of retinal vessels.

UR - http://www.scopus.com/inward/record.url?scp=65549090965&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=65549090965&partnerID=8YFLogxK

U2 - 10.1117/12.807537

DO - 10.1117/12.807537

M3 - Conference article

VL - 7163

JO - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

JF - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

SN - 1605-7422

M1 - 71631N

ER -