Autoregressive analysis of aortic input impedance: Comparison with Fourier transform

T. Kubota, R. Itaya, J. Alexander, Koji Todaka, M. Sugimachi, K. Sunagawa

研究成果: ジャーナルへの寄稿記事

6 引用 (Scopus)

抄録

We evaluated the advantages of the autoregressive (AR) model over the conventional Fourier transform in estimating aortic input impedance. In 10 anesthetized open-chest dogs, we digitized aortic pressure and flow at 200 Hz for 51.20 s under random ventricular pacing and subdivided them into five segments. We obtained aortic input impedance over the frequency range of 0.1-20 Hz both by AR model and by Fourier transform for various lengths of data, i.e., from one to four consecutive segments. For any given data length, the impedance spectrum estimated by the AR model was smoother than that obtained by the Fourier transform. To evaluate the accuracy of the estimated impedance, we predicted instantaneous aortic pressure of the fifth segment by convolving corresponding aortic flow with the impulse response of aortic input impedance. The prediction error was less with the AR model than that resulting from Fourier transform as long as the number of the segments was less than four. We conclude that the AR model provides a more accurate estimate of aortic input impedance than does the Fourier transform when data length is limited.

元の言語英語
ジャーナルAmerican Journal of Physiology - Heart and Circulatory Physiology
260
発行部数3 29-3
出版物ステータス出版済み - 1991

Fingerprint

Fourier Analysis
Electric Impedance
Arterial Pressure
Thorax
Dogs

All Science Journal Classification (ASJC) codes

  • Physiology

これを引用

Autoregressive analysis of aortic input impedance : Comparison with Fourier transform. / Kubota, T.; Itaya, R.; Alexander, J.; Todaka, Koji; Sugimachi, M.; Sunagawa, K.

:: American Journal of Physiology - Heart and Circulatory Physiology, 巻 260, 番号 3 29-3, 1991.

研究成果: ジャーナルへの寄稿記事

Kubota, T. ; Itaya, R. ; Alexander, J. ; Todaka, Koji ; Sugimachi, M. ; Sunagawa, K. / Autoregressive analysis of aortic input impedance : Comparison with Fourier transform. :: American Journal of Physiology - Heart and Circulatory Physiology. 1991 ; 巻 260, 番号 3 29-3.
@article{70a325c40da04d86aa61d881224bf8d2,
title = "Autoregressive analysis of aortic input impedance: Comparison with Fourier transform",
abstract = "We evaluated the advantages of the autoregressive (AR) model over the conventional Fourier transform in estimating aortic input impedance. In 10 anesthetized open-chest dogs, we digitized aortic pressure and flow at 200 Hz for 51.20 s under random ventricular pacing and subdivided them into five segments. We obtained aortic input impedance over the frequency range of 0.1-20 Hz both by AR model and by Fourier transform for various lengths of data, i.e., from one to four consecutive segments. For any given data length, the impedance spectrum estimated by the AR model was smoother than that obtained by the Fourier transform. To evaluate the accuracy of the estimated impedance, we predicted instantaneous aortic pressure of the fifth segment by convolving corresponding aortic flow with the impulse response of aortic input impedance. The prediction error was less with the AR model than that resulting from Fourier transform as long as the number of the segments was less than four. We conclude that the AR model provides a more accurate estimate of aortic input impedance than does the Fourier transform when data length is limited.",
author = "T. Kubota and R. Itaya and J. Alexander and Koji Todaka and M. Sugimachi and K. Sunagawa",
year = "1991",
language = "English",
volume = "260",
journal = "American Journal of Physiology - Heart and Circulatory Physiology",
issn = "0363-6135",
publisher = "American Physiological Society",
number = "3 29-3",

}

TY - JOUR

T1 - Autoregressive analysis of aortic input impedance

T2 - Comparison with Fourier transform

AU - Kubota, T.

AU - Itaya, R.

AU - Alexander, J.

AU - Todaka, Koji

AU - Sugimachi, M.

AU - Sunagawa, K.

PY - 1991

Y1 - 1991

N2 - We evaluated the advantages of the autoregressive (AR) model over the conventional Fourier transform in estimating aortic input impedance. In 10 anesthetized open-chest dogs, we digitized aortic pressure and flow at 200 Hz for 51.20 s under random ventricular pacing and subdivided them into five segments. We obtained aortic input impedance over the frequency range of 0.1-20 Hz both by AR model and by Fourier transform for various lengths of data, i.e., from one to four consecutive segments. For any given data length, the impedance spectrum estimated by the AR model was smoother than that obtained by the Fourier transform. To evaluate the accuracy of the estimated impedance, we predicted instantaneous aortic pressure of the fifth segment by convolving corresponding aortic flow with the impulse response of aortic input impedance. The prediction error was less with the AR model than that resulting from Fourier transform as long as the number of the segments was less than four. We conclude that the AR model provides a more accurate estimate of aortic input impedance than does the Fourier transform when data length is limited.

AB - We evaluated the advantages of the autoregressive (AR) model over the conventional Fourier transform in estimating aortic input impedance. In 10 anesthetized open-chest dogs, we digitized aortic pressure and flow at 200 Hz for 51.20 s under random ventricular pacing and subdivided them into five segments. We obtained aortic input impedance over the frequency range of 0.1-20 Hz both by AR model and by Fourier transform for various lengths of data, i.e., from one to four consecutive segments. For any given data length, the impedance spectrum estimated by the AR model was smoother than that obtained by the Fourier transform. To evaluate the accuracy of the estimated impedance, we predicted instantaneous aortic pressure of the fifth segment by convolving corresponding aortic flow with the impulse response of aortic input impedance. The prediction error was less with the AR model than that resulting from Fourier transform as long as the number of the segments was less than four. We conclude that the AR model provides a more accurate estimate of aortic input impedance than does the Fourier transform when data length is limited.

UR - http://www.scopus.com/inward/record.url?scp=0025878318&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025878318&partnerID=8YFLogxK

M3 - Article

C2 - 2000993

AN - SCOPUS:0025878318

VL - 260

JO - American Journal of Physiology - Heart and Circulatory Physiology

JF - American Journal of Physiology - Heart and Circulatory Physiology

SN - 0363-6135

IS - 3 29-3

ER -