Basic and experimental study of contra-rotating axial flow pump

Yin Chun Cao, Akinori Furukawa, Kusuo Okuma, Takahiro Chono, Satoshi Watanabe

研究成果: Contribution to journalArticle査読

1 被引用数 (Scopus)

抄録

Demands for higher performance of axial flow pumps have led pump designers to consider the creative strategies for the new type. As a solution, contra-rotating rotors might be applied to a pump. Comparative experiments were conducted for two types, consisting of contra-rotating rotors and a rotor and a stator respectively, which were designed under the same specifications of pump head, flow rate and rotor specific speed. The measured pump performances and flow distributions are shown and the advantages of using contra-rotating type are clarified as follows. Contra-rotating type is superior in-pump efficiency and cavitation performance in range of partial flow rates to conventional one though the specified pump head and maximum efficiency were not satisfied at design point in the case of contra-rotating test rotors. Kesults demonstrate that the rear rotor design is important to improve the pump efficiency.

本文言語英語
ページ(範囲)1184-1190
ページ数7
ジャーナルNihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B
67
657
DOI
出版ステータス出版済み - 5 2001
外部発表はい

All Science Journal Classification (ASJC) codes

  • 凝縮系物理学
  • 機械工学

フィンガープリント

「Basic and experimental study of contra-rotating axial flow pump」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。