Beam test of novel n-in-p strip sensors for high radiation environment

T. Kubota, T. Kishida, O. Jinnouchi, Y. Ikegami, Y. Unno, S. Terada, S. Mitsui, A. Tamii, T. Aoi, K. Hanagaki, K. Hara, N. Kimura, R. Takashima, Y. Takubo, J. Tojo, K. Nagai, I. Nakano, K. Yorita

研究成果: ジャーナルへの寄稿学術誌査読

抄録

Highly radiation tolerant n-in-p strip sensors have been developed for the high-luminosity LHC (HL-LHC). This paper reports the results of measurements with 392 MeV kinetic energy proton beam at RCNP in December 2011. The data was taken with a new DAQ system consisting of an universal read-out board 'SEABAS' and beam tracking telescopes whose spacial resolution is better than 5μm. The aim of this beam test is to evaluate the new 1 cm×1 cm n-in-p miniature sensors before and after 1015 neq cm-2 irradiation. The median charge of un-irradiated sensor is 6.2 fC at full depletion voltage, while the median charge after 1015 neq cm-2 irradiation of the sensor is 4.2 fC. The novel Punch-Through-Protection (PTP) has been implemented in these sensors. The length of active region of the sensor around PTP is observed to be decreased by 12μm in the irradiated sensors at 1015 neq cm -2.

本文言語英語
ページ(範囲)247-251
ページ数5
ジャーナルNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
731
DOI
出版ステータス出版済み - 2013

!!!All Science Journal Classification (ASJC) codes

  • 核物理学および高エネルギー物理学
  • 器械工学

フィンガープリント

「Beam test of novel n-in-p strip sensors for high radiation environment」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル