Calculation of recovery rates of tritium from Flibe blanket

Satoshi Fukada, Masabumi Nishikawa, Akio Sagara

研究成果: ジャーナルへの寄稿記事

10 引用 (Scopus)

抄録

Rates of continuous tritium recovery from a Flibe stream are calculated for a permeation window and a counter-current gas-bubble column. The area of the permeation window is estimated to be comparatively small unless very low tritium partial pressure is demanded for the system. It is probable that the tritium transfer rate is controlled not by permeation through the window material (Nb or ferrite steel) but diffusion in Flibe. Since tritium diffusion in the molten salt is also determination of the recovery rate in the gas-bubble column from Flibe to He, the evaluation of the tritium diffusion resistance in the molten salt is crucial for its design.

元の言語英語
ページ(範囲)1073-1077
ページ数5
ジャーナルFusion Technology
39
発行部数2
出版物ステータス出版済み - 2001

Fingerprint

Tritium
blankets
tritium
recovery
Recovery
Permeation
Bubble columns
molten salts
Molten materials
bubbles
Salts
Gases
Steel
gases
Partial pressure
partial pressure
Ferrite
ferrites
counters
steels

All Science Journal Classification (ASJC) codes

  • Engineering(all)

これを引用

Fukada, S., Nishikawa, M., & Sagara, A. (2001). Calculation of recovery rates of tritium from Flibe blanket. Fusion Technology, 39(2), 1073-1077.

Calculation of recovery rates of tritium from Flibe blanket. / Fukada, Satoshi; Nishikawa, Masabumi; Sagara, Akio.

:: Fusion Technology, 巻 39, 番号 2, 2001, p. 1073-1077.

研究成果: ジャーナルへの寄稿記事

Fukada, S, Nishikawa, M & Sagara, A 2001, 'Calculation of recovery rates of tritium from Flibe blanket', Fusion Technology, 巻. 39, 番号 2, pp. 1073-1077.
Fukada S, Nishikawa M, Sagara A. Calculation of recovery rates of tritium from Flibe blanket. Fusion Technology. 2001;39(2):1073-1077.
Fukada, Satoshi ; Nishikawa, Masabumi ; Sagara, Akio. / Calculation of recovery rates of tritium from Flibe blanket. :: Fusion Technology. 2001 ; 巻 39, 番号 2. pp. 1073-1077.
@article{79efba8dd8754d41be81777f5b50cae3,
title = "Calculation of recovery rates of tritium from Flibe blanket",
abstract = "Rates of continuous tritium recovery from a Flibe stream are calculated for a permeation window and a counter-current gas-bubble column. The area of the permeation window is estimated to be comparatively small unless very low tritium partial pressure is demanded for the system. It is probable that the tritium transfer rate is controlled not by permeation through the window material (Nb or ferrite steel) but diffusion in Flibe. Since tritium diffusion in the molten salt is also determination of the recovery rate in the gas-bubble column from Flibe to He, the evaluation of the tritium diffusion resistance in the molten salt is crucial for its design.",
author = "Satoshi Fukada and Masabumi Nishikawa and Akio Sagara",
year = "2001",
language = "English",
volume = "39",
pages = "1073--1077",
journal = "Fusion Science and Technology",
issn = "1536-1055",
publisher = "American Nuclear Society",
number = "2",

}

TY - JOUR

T1 - Calculation of recovery rates of tritium from Flibe blanket

AU - Fukada, Satoshi

AU - Nishikawa, Masabumi

AU - Sagara, Akio

PY - 2001

Y1 - 2001

N2 - Rates of continuous tritium recovery from a Flibe stream are calculated for a permeation window and a counter-current gas-bubble column. The area of the permeation window is estimated to be comparatively small unless very low tritium partial pressure is demanded for the system. It is probable that the tritium transfer rate is controlled not by permeation through the window material (Nb or ferrite steel) but diffusion in Flibe. Since tritium diffusion in the molten salt is also determination of the recovery rate in the gas-bubble column from Flibe to He, the evaluation of the tritium diffusion resistance in the molten salt is crucial for its design.

AB - Rates of continuous tritium recovery from a Flibe stream are calculated for a permeation window and a counter-current gas-bubble column. The area of the permeation window is estimated to be comparatively small unless very low tritium partial pressure is demanded for the system. It is probable that the tritium transfer rate is controlled not by permeation through the window material (Nb or ferrite steel) but diffusion in Flibe. Since tritium diffusion in the molten salt is also determination of the recovery rate in the gas-bubble column from Flibe to He, the evaluation of the tritium diffusion resistance in the molten salt is crucial for its design.

UR - http://www.scopus.com/inward/record.url?scp=0035270220&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035270220&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0035270220

VL - 39

SP - 1073

EP - 1077

JO - Fusion Science and Technology

JF - Fusion Science and Technology

SN - 1536-1055

IS - 2