Characteristics of a 6Li-loaded neutron coincidence spectrometer were investigated from both measurements and Monte Carlo simulations. The spectrometer consists of three 6Li-glass scintillators embedded in a liquid organic scintillator BC-501A, which can detect selectively neutrons that deposit the total energy in the BC-501A using a coincidence signal generated from the capture event of thermalised neutrons in the 6Li-glass scintillators. The relative efficiency and the energy response were measured using 4.7, 7.2 and 9.0 MeV monoenergetic neutrons. The measured ones were compared with the Monte Carlo calculations performed by combining the neutron transport code PHITS and the scintillator response calculation code SCINFUL. The experimental light output spectra were in good agreement with the calculated ones in shape. The energy dependence of the detection efficiency was reproduced by the calculation. The response matrices for 1-10 MeV neutrons were finally obtained.

元の言語英語
ページ(範囲)376-379
ページ数4
ジャーナルRadiation Protection Dosimetry
126
発行部数1-4
DOI
出版物ステータス出版済み - 12 1 2007

Fingerprint

lithium isotopes
Neutrons
Lithium
spectrometers
neutrons
scintillation counters
evaluation
Glass
organic liquids
glass
energy
deposits
Light
output
matrices

All Science Journal Classification (ASJC) codes

  • Radiological and Ultrasound Technology
  • Radiation
  • Radiology Nuclear Medicine and imaging
  • Public Health, Environmental and Occupational Health

これを引用

Characteristic evaluation of a Lithium-6 loaded neutron coincidence spectrometer. / Hayashi, M.; Kaku, D.; Watanabe, Yukinobu; Sagara, K.

:: Radiation Protection Dosimetry, 巻 126, 番号 1-4, 01.12.2007, p. 376-379.

研究成果: ジャーナルへの寄稿記事

@article{3fc2dbe2e63e4f809a508f63fd6beceb,
title = "Characteristic evaluation of a Lithium-6 loaded neutron coincidence spectrometer",
abstract = "Characteristics of a 6Li-loaded neutron coincidence spectrometer were investigated from both measurements and Monte Carlo simulations. The spectrometer consists of three 6Li-glass scintillators embedded in a liquid organic scintillator BC-501A, which can detect selectively neutrons that deposit the total energy in the BC-501A using a coincidence signal generated from the capture event of thermalised neutrons in the 6Li-glass scintillators. The relative efficiency and the energy response were measured using 4.7, 7.2 and 9.0 MeV monoenergetic neutrons. The measured ones were compared with the Monte Carlo calculations performed by combining the neutron transport code PHITS and the scintillator response calculation code SCINFUL. The experimental light output spectra were in good agreement with the calculated ones in shape. The energy dependence of the detection efficiency was reproduced by the calculation. The response matrices for 1-10 MeV neutrons were finally obtained.",
author = "M. Hayashi and D. Kaku and Yukinobu Watanabe and K. Sagara",
year = "2007",
month = "12",
day = "1",
doi = "10.1093/rpd/ncm078",
language = "English",
volume = "126",
pages = "376--379",
journal = "Radiation Protection Dosimetry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1-4",

}

TY - JOUR

T1 - Characteristic evaluation of a Lithium-6 loaded neutron coincidence spectrometer

AU - Hayashi, M.

AU - Kaku, D.

AU - Watanabe, Yukinobu

AU - Sagara, K.

PY - 2007/12/1

Y1 - 2007/12/1

N2 - Characteristics of a 6Li-loaded neutron coincidence spectrometer were investigated from both measurements and Monte Carlo simulations. The spectrometer consists of three 6Li-glass scintillators embedded in a liquid organic scintillator BC-501A, which can detect selectively neutrons that deposit the total energy in the BC-501A using a coincidence signal generated from the capture event of thermalised neutrons in the 6Li-glass scintillators. The relative efficiency and the energy response were measured using 4.7, 7.2 and 9.0 MeV monoenergetic neutrons. The measured ones were compared with the Monte Carlo calculations performed by combining the neutron transport code PHITS and the scintillator response calculation code SCINFUL. The experimental light output spectra were in good agreement with the calculated ones in shape. The energy dependence of the detection efficiency was reproduced by the calculation. The response matrices for 1-10 MeV neutrons were finally obtained.

AB - Characteristics of a 6Li-loaded neutron coincidence spectrometer were investigated from both measurements and Monte Carlo simulations. The spectrometer consists of three 6Li-glass scintillators embedded in a liquid organic scintillator BC-501A, which can detect selectively neutrons that deposit the total energy in the BC-501A using a coincidence signal generated from the capture event of thermalised neutrons in the 6Li-glass scintillators. The relative efficiency and the energy response were measured using 4.7, 7.2 and 9.0 MeV monoenergetic neutrons. The measured ones were compared with the Monte Carlo calculations performed by combining the neutron transport code PHITS and the scintillator response calculation code SCINFUL. The experimental light output spectra were in good agreement with the calculated ones in shape. The energy dependence of the detection efficiency was reproduced by the calculation. The response matrices for 1-10 MeV neutrons were finally obtained.

UR - http://www.scopus.com/inward/record.url?scp=52249094009&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=52249094009&partnerID=8YFLogxK

U2 - 10.1093/rpd/ncm078

DO - 10.1093/rpd/ncm078

M3 - Article

C2 - 17616546

AN - SCOPUS:52249094009

VL - 126

SP - 376

EP - 379

JO - Radiation Protection Dosimetry

JF - Radiation Protection Dosimetry

SN - 0144-8420

IS - 1-4

ER -