Characterization of magnetic markers for liquid-phase detection of biological targets

Yuichi Higuchi, Shinobu Uchida, Anwarul Kabir Bhuiya, Takashi Yoshida, Keiji Enpuku

研究成果: ジャーナルへの寄稿記事

10 引用 (Scopus)

抄録

We characterized the properties of magnetic markers for liquid phase immunoassays using Brownian relaxation. Since magnetic markers are usually composed of aggregated magnetic nanoparticles, their properties are significantly affected by the degree of aggregation. Through the analysis of magnetization (M-H) and AC susceptibility measurements, we obtained the distribution of the magnetic moment m and the Neel relaxation time τN of the aggregated particles included in the markers. We also determined the relationship between m and τN. From the obtained result, we could classify the particles into three types: Type-1 particles with very small m and very short τN , Type-2 particles with medium values of m and τN, and Type-3 particles with large m and very long τN. The proportion of these three types of particles included in the marker was also evaluated. We show that Type-3 particles and some Type-2 particles with τ N > τB are primarily responsible for the observed signal in the liquid phase immunoassay using Brownian relaxation, where τB is the Brownian relaxation time. The obtained results are useful for evaluating suitable markers for liquid phase immunoassays using Brownian relaxation.

元の言語英語
記事番号6558894
ページ(範囲)3456-3459
ページ数4
ジャーナルIEEE Transactions on Magnetics
49
発行部数7
DOI
出版物ステータス出版済み - 8 5 2013

Fingerprint

Relaxation time
Liquids
Magnetic moments
Magnetization
Agglomeration
Nanoparticles

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

これを引用

Characterization of magnetic markers for liquid-phase detection of biological targets. / Higuchi, Yuichi; Uchida, Shinobu; Bhuiya, Anwarul Kabir; Yoshida, Takashi; Enpuku, Keiji.

:: IEEE Transactions on Magnetics, 巻 49, 番号 7, 6558894, 05.08.2013, p. 3456-3459.

研究成果: ジャーナルへの寄稿記事

Higuchi, Yuichi ; Uchida, Shinobu ; Bhuiya, Anwarul Kabir ; Yoshida, Takashi ; Enpuku, Keiji. / Characterization of magnetic markers for liquid-phase detection of biological targets. :: IEEE Transactions on Magnetics. 2013 ; 巻 49, 番号 7. pp. 3456-3459.
@article{d39f602b607c4435a93ca4fe0751bd5b,
title = "Characterization of magnetic markers for liquid-phase detection of biological targets",
abstract = "We characterized the properties of magnetic markers for liquid phase immunoassays using Brownian relaxation. Since magnetic markers are usually composed of aggregated magnetic nanoparticles, their properties are significantly affected by the degree of aggregation. Through the analysis of magnetization (M-H) and AC susceptibility measurements, we obtained the distribution of the magnetic moment m and the Neel relaxation time τN of the aggregated particles included in the markers. We also determined the relationship between m and τN. From the obtained result, we could classify the particles into three types: Type-1 particles with very small m and very short τN , Type-2 particles with medium values of m and τN, and Type-3 particles with large m and very long τN. The proportion of these three types of particles included in the marker was also evaluated. We show that Type-3 particles and some Type-2 particles with τ N > τB are primarily responsible for the observed signal in the liquid phase immunoassay using Brownian relaxation, where τB is the Brownian relaxation time. The obtained results are useful for evaluating suitable markers for liquid phase immunoassays using Brownian relaxation.",
author = "Yuichi Higuchi and Shinobu Uchida and Bhuiya, {Anwarul Kabir} and Takashi Yoshida and Keiji Enpuku",
year = "2013",
month = "8",
day = "5",
doi = "10.1109/TMAG.2013.2242852",
language = "English",
volume = "49",
pages = "3456--3459",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "7",

}

TY - JOUR

T1 - Characterization of magnetic markers for liquid-phase detection of biological targets

AU - Higuchi, Yuichi

AU - Uchida, Shinobu

AU - Bhuiya, Anwarul Kabir

AU - Yoshida, Takashi

AU - Enpuku, Keiji

PY - 2013/8/5

Y1 - 2013/8/5

N2 - We characterized the properties of magnetic markers for liquid phase immunoassays using Brownian relaxation. Since magnetic markers are usually composed of aggregated magnetic nanoparticles, their properties are significantly affected by the degree of aggregation. Through the analysis of magnetization (M-H) and AC susceptibility measurements, we obtained the distribution of the magnetic moment m and the Neel relaxation time τN of the aggregated particles included in the markers. We also determined the relationship between m and τN. From the obtained result, we could classify the particles into three types: Type-1 particles with very small m and very short τN , Type-2 particles with medium values of m and τN, and Type-3 particles with large m and very long τN. The proportion of these three types of particles included in the marker was also evaluated. We show that Type-3 particles and some Type-2 particles with τ N > τB are primarily responsible for the observed signal in the liquid phase immunoassay using Brownian relaxation, where τB is the Brownian relaxation time. The obtained results are useful for evaluating suitable markers for liquid phase immunoassays using Brownian relaxation.

AB - We characterized the properties of magnetic markers for liquid phase immunoassays using Brownian relaxation. Since magnetic markers are usually composed of aggregated magnetic nanoparticles, their properties are significantly affected by the degree of aggregation. Through the analysis of magnetization (M-H) and AC susceptibility measurements, we obtained the distribution of the magnetic moment m and the Neel relaxation time τN of the aggregated particles included in the markers. We also determined the relationship between m and τN. From the obtained result, we could classify the particles into three types: Type-1 particles with very small m and very short τN , Type-2 particles with medium values of m and τN, and Type-3 particles with large m and very long τN. The proportion of these three types of particles included in the marker was also evaluated. We show that Type-3 particles and some Type-2 particles with τ N > τB are primarily responsible for the observed signal in the liquid phase immunoassay using Brownian relaxation, where τB is the Brownian relaxation time. The obtained results are useful for evaluating suitable markers for liquid phase immunoassays using Brownian relaxation.

UR - http://www.scopus.com/inward/record.url?scp=84880854784&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880854784&partnerID=8YFLogxK

U2 - 10.1109/TMAG.2013.2242852

DO - 10.1109/TMAG.2013.2242852

M3 - Article

VL - 49

SP - 3456

EP - 3459

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 7

M1 - 6558894

ER -